Sachin Kothari

Sachin Kothari

Auto-generated profile, based on publicly available information

Sachin Kothari

University of Chicago

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
RMRami Z Morsi
Rami Z Morsi
SKSachin A Kothari
Sachin A Kothari
STSonam Thind
Sonam Thind
HDHarsh Desai
Harsh Desai
SPSean P Polster
Sean P Polster
TKTareq Kass-Hout
Tareq Kass-Hout
Background The transradial approach (TRA) for neurointerventional procedures is increasingly being used given its technical feasibility and safety. However, catheter trackability and device deliverability are reported barriers to TRA adoption. Methods This is the first report describing the technical feasibility and performance of using the Zoom RDL Radial Access System (Imperative Care, Inc., Campbell, CA) in 29 patients who underwent neurointerventional procedures from October 2022 to January 2023 in a single-center institution. Results Mean age of the study population was 61.9±17.2 years, 79.3% were male (23/29), and 62.1% were black (18/29). The most common procedures were stroke thrombectomy (31.0%, 9/29) and aneurysm embolization (27.6%, 8/29). All the stroke thrombectomy procedures were successfully performed; first-pass effect rate (mTICI≥2 c in one pass) was achieved in 66.7% (6/9) of cases. We used TRA in 86.2% of cases (25/29), including distal radial/snuffbox access in 31.0% (9/29) of cases. The radial diameter was >2 mm for all cases. An intermediate/aspiration catheter was used in 89.7% (26/29) of cases. Access success was achieved in 89.7% of cases (26/29); two cases required conversion from TRA to transfemoral approach (6.9%) and one case required conversion to a different guide catheter (3.4%). There were no access site complications or other Zoom RDL-related complications. One intracerebral hemorrhage, and one procedure-related thrombus were observed. Conclusions The use of Zoom RDL Radial Access System is technically feasible and effective for complex neurointerventional procedures with low complication rates.

3 January 2024 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
RMRami Z Morsi
Rami Z Morsi
STSonam Thind
Sonam Thind
ACAhmad Chahine
Ahmad Chahine
JZJehad Zakaria
Jehad Zakaria
HDHarsh Desai
Harsh Desai
TKTareq Kass-Hout
Tareq Kass-Hout
Background The use of covered stent grafts for the treatment of carotid rupture is increasingly being used given their ability to preserve the parent artery while simultaneously occluding the fistula or rupture point. Methods This case series describes the technical feasibility of using, and the performance of, the PK Papyrus covered coronary stent (Biotronik, Inc., Lake Oswego, Oregon, USA) in six patients with carotid rupture, including carotid cavernous fistulas, between July 2021 and October 2023 in a single-center institution in the USA. Results The median decade of life was 5 (IQR 3) with a 1:1 male-to-female ratio. The majority were black patients (n=5/6, 83.3%). The most common disease pathology was carotid cavernous fistula (n=4/6, 66.7%), followed by traumatic carotid rupture (n=2/6, 33.3%). All the stent embolization procedures were successfully treated with the PK Papyrus covered coronary stent. None of the patients had any recurrence or re-treatment. The number of stents required ranged from 1 to 3. A balloon guide catheter was used in 66.7% of cases (n=4/6). In-hospital mortality was 0.0% (n=0/6). No in-stent thrombosis was observed, but there was one case of cangrelor-associated hemorrhagic stroke conversion. Transfemoral access was used in all cases with one access site complication. Median follow-up time was 1.8 months (IQR 3.5). Conclusions To our knowledge, this is the largest case series in the USA demonstrating the feasibility and safety of using the PK Papyrus covered coronary stent for the treatment of carotid rupture, including carotid cavernous fistulas.

2 November 2024 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
SKSachin A Kothari
Sachin A Kothari
RMRami Z Morsi
Rami Z Morsi
OKOlivia Kozel
Olivia Kozel
ABArchit Baskaran
Archit Baskaran
NSNeha Sehgal
Neha Sehgal
TKTareq Kass-Hout
Tareq Kass-Hout
Background Rapid prehospital identification of acute ischemic stroke secondary to large vessel occlusions (AIS-LVO) has been successful in triaging patients, but the use of stroke screening scales often varies. This study aims to compare different stroke screening scales for the detection of anterior and posterior circulation AIS-LVO and AIS secondary to medium vessel occlusions (AIS-MeVO). Methods We prospectively analyzed stroke alert activations at a comprehensive stroke center between August 1, 2022 and December 31, 2023. We applied eight stroke screening scales (BE-FAST, LAMS, PASS, FAST-ED, EMS RACE, 3-ISS, VAN, and NIHSS) to each stroke alert in the emergency department (ED) and inpatient wards. The final diagnosis was classified as AIS-LVO or AIS-MeVO, AIS without LVO or MeVO, intracranial hemorrhage, transient ischemic attack, or stroke mimic. Results A total of 198 patients were analyzed. The mean age was 63.9±15.3 years, 62.1% were female (n=123), and 84.3% were African American/black subjects (n=167). The LAMS scale had a strong performance (area under the curve (AUC) 0.750 (95% CI 0.668 to 0.831)), closely followed by the FAST-ED (AUC 0.736 (95% CI 0.649 to 0.822)) and the VAN (AUC 0.735 (95% CI 0.651 to 0.818)) scales. Cut-off points selected from coordinates of the receiver operating characteristic curves were 3, 3, and a positive VAN, respectively. Conclusion This is the first prospective cohort study to compare the performance of eight different screening scales among stroke alerts for detection of AIS-LVO and AIS-MeVO. We found LAMS to be the most discriminative tool, followed by FAST-ED and VAN. However, the findings were non-significant, reinforcing existing retrospective literature that these validated screening scales perform similarly and one is not superior.

23 January 2023 in Interventional Neuroradiology
Verified
Journal Article
Closed access
SKSachin Kothari
Sachin Kothari
RMRami Z Morsi
Rami Z Morsi
STSonam Thind
Sonam Thind
ATAmmar Tarabichi
Ammar Tarabichi
JCJulian Carrión-Penagos
Julian Carrión-Penagos
TKTareq Kass-Hout
Tareq Kass-Hout
We present a 35-year-old male with ulcerative colitis initially admitted for a flare-up who then presented with altered mental status and was found to have extensive cerebral venous sinus thrombosis on computed tomography imaging. The patient underwent successful partial recanalization of the superior sagittal sinus and bilateral transverse sinuses using the Penumbra Indigo® Aspiration System with improved outcomes. To our knowledge, this is the first reported use of this device in the treatment of cerebral venous sinus thrombosis.

23 May 2025 in Surgical Neurology International
Verified
Journal Article
Open access
ABArchit Bharathwaj Baskaran
Archit Bharathwaj Baskaran
AJAditya Jhaveri
Aditya Jhaveri
OKOlivia Kozel
Olivia Kozel
CAChibueze Ikechukwu Agwu
Chibueze Ikechukwu Agwu
SKSachin Kothari
Sachin Kothari
JSJames E. Siegler
James E. Siegler
Background: A type II proatlantal artery is a rare congenital vascular anomaly comprised of a persistent embryologic connection between the carotid and vertebrobasilar circulations. Although generally asymptomatic and detected incidentally, its identification is of clinical importance in neurovascular assessments and interventions. Case Description: A 70-year-old male presented with acute-onset left lower extremity weakness and numbness, out of the window for thrombolytics; computed tomography angiography of the head and neck incidentally identifying a persistent left type II proatlantal artery originating from the external carotid artery and supplying the vertebrobasilar circulation. Magnetic resonance imaging of the brain the following day was unremarkable for acute infarction or other cerebrovascular pathology. Conclusion: This case underscores the significance of recognizing congenital vascular anomalies such as the type II proatlantal artery, particularly in the context of cerebrovascular assessment. Although these variants are often incidental and not associated with increased stroke risk, their presence has implications for neuroendovascular procedures and stroke evaluations. Understanding the anatomic and embryologic origins of these vascular anomalies facilitates accurate interpretation of cerebrovascular imaging and enhances clinical decision-making in patients with these anomalies.

1 August 2025 in Interventional Neuroradiology
Verified
Journal Article
Closed access
SKSachin A Kothari
Sachin A Kothari
RMRami Z Morsi
Rami Z Morsi
EGElena Badillo Goicoechea
Elena Badillo Goicoechea
HDHarsh Desai
Harsh Desai
ABArchit Baskaran
Archit Baskaran
TKTareq Kass-Hout
Tareq Kass-Hout
Background: Prehospital stroke screening for large vessel occlusions (LVOs) varies across institutions. This study compares manual stroke scale calculations against e-calculated scores using the Ultimate Stroke Scale (USS), a software automating multiple screening scales from a modified National Institutes of Health Stroke Scale (NIHSS) with a hand grip. The USS aims to streamline screening by computing multiple validated stroke scales simultaneously to enhance predictive value. Methods: We applied eight stroke screening scales (NIHSS; Balance, Eyes, Face, Arms, Speech, and Time [BE-FAST]; Vision, Aphasia, Neglect; Los Angeles Motor Scale [LAMS]; Face, Arm, Speech, Time, Eye Deviation and Denial/Neglect [FAST-ED]; Emergency Medical Services Rapid Arterial oCclusion Evaluation [EMS RACE]; 3-Item Stroke Scale [3-ISS]; and Prehospital Acute Stroke Severity [PASS]) to 199 stroke activations between January 2021 and December 2023. In this prospective, external validation study, data were utilized from a previously published head-to-head comparison of multiple LVO scales for both LVOs and medium vessel occlusions which collected scales manually. We recalculated these scales using the USS and evaluated agreement (Kendall's τ) and diagnostic accuracy (ROC curves). Results: The USS showed strong to moderate agreement with manual calculations across all scales displayed by Kendall's τ correlation coefficients ranging from 0.549 to 0.931 (all p < 0.001). The BE-FAST had the lowest agreement (τ = 0.549), while PASS had the highest (τ = 0.931), followed by LAMS (τ = 0.894) and FAST-ED (τ = 0.864). Diagnostic accuracy was comparable between manual methods (area under the curve [AUC]: 0.590–0.743) and the USS (AUC: 0.575–0.758). The BE-FAST had the lowest AUC for both, LAMS had the highest for manual, and FAST-ED had the highest from the USS. Conclusion: The USS demonstrates potential as a reliable tool for automated stroke screening with consistent performance compared to manual methods.