Vladislav Gerginov

Vladislav Gerginov

Auto-generated profile, based on publicly available information

Vladislav Gerginov

National Institute of Standards and Technology, 325 Broadway St, Boulder, CO 80305, United States of America

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2014 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
NHN. Huntemann
N. Huntemann
BLB. Lipphardt
B. Lipphardt
CTChr. Tamm
Chr. Tamm
VGV. Gerginov
V. Gerginov
SWS. Weyers
S. Weyers
EPE. Peik
E. Peik
Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant α and the proton-to-electron mass ratio μ. We measure the frequency of the S1/22→F7/22 electric octupole (E3) transition in Yb+171 against two caesium fountain clocks as f(E3)=642 121 496 772 645.36  Hz with an improved fractional uncertainty of 3.9×10−16. This transition frequency shows a strong sensitivity to changes of α. Together with a number of previous and recent measurements of the S1/22→D3/22 electric quadrupole transition in Yb+171 and with data from other elements, a least-squares analysis yields (1/α)(dα/dt)=−0.20(20)×10−16/yr and (1/μ)(dμ/dt)=−0.5(1.6)×10−16/yr, confirming a previous limit on dα/dt and providing the most stringent limit on dμ/dt from laboratory experiments.

1 July 2014 in New Journal of Physics
Verified
Journal Article
Open access
SFStephan Falke
Stephan Falke
NLNathan Lemke
Nathan Lemke
CGChristian Grebing
Christian Grebing
BLBurghard Lipphardt
Burghard Lipphardt
SWStefan Weyers
Stefan Weyers
CLChristian Lisdat
Christian Lisdat

15 September 2005 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SKS. Knappe
S. Knappe
VGV. Gerginov
V. Gerginov
PSP. D.D. Schwindt
P. D.D. Schwindt
VSV. Shah
V. Shah
HRH. G. Robinson
H. G. Robinson
JKJ. Kitching
J. Kitching
A novel technique for microfabricating alkali atom vapor cells is described in which alkali atoms are evaporated into a micromachined cell cavity through a glass nozzle. A cell of interior volume 1 mm3, containing Rb87 and a buffer gas, was made in this way and integrated into an atomic clock based on coherent population trapping. A fractional frequency instability of 6×10−12 at 1000 s of integration was measured. The long-term drift of the F=1, mF=0→F=2, mF=0 hyperfine frequency of atoms in these cells is below 5×10−11∕day.

25 May 2016 in Optica
Verified
Journal Article
Open access
PDF file
CGChristian Grebing
Christian Grebing
AAAli Al-Masoudi
Ali Al-Masoudi
SDSören Dörscher
Sören Dörscher
SHSebastian Häfner
Sebastian Häfner
VGVladislav Gerginov
Vladislav Gerginov
CLChristian Lisdat
Christian Lisdat
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the redefinition of the SI base unit “second,” as they now surpass the performance of cesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of optical clocks, which made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and show that a timescale based on an optical clock can be established that is superior to one based on even the best cesium fountain clocks. The paper also gives further proof of the international consistency of strontium lattice clocks on the 10−16 accuracy level, which is another prerequisite for a change in the definition of the second.

19 October 2018 in Metrologia
Verified
Journal Article
Closed access
PDF file
SWStefan Weyers
Stefan Weyers
VGVladislav Gerginov
Vladislav Gerginov
MKMichael Kazda
Michael Kazda
JRJohannes Martin Rahm
Johannes Martin Rahm
BLBurghard Lipphardt
Burghard Lipphardt
KGKurt Gibble
Kurt Gibble
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to for CSF1 and for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to and , respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.

22 December 2009 in Metrologia
Verified
Journal Article
Closed access
VGV Gerginov
V Gerginov
NNN Nemitz
N Nemitz
SWS Weyers
S Weyers
RSR Schröder
R Schröder
DGD Griebsch
D Griebsch
RWR Wynands
R Wynands