Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant and the proton-to-electron mass ratio . We measure the frequency of the electric octupole () transition in against two caesium fountain clocks as with an improved fractional uncertainty of . This transition frequency shows a strong sensitivity to changes of . Together with a number of previous and recent measurements of the electric quadrupole transition in and with data from other elements, a least-squares analysis yields and , confirming a previous limit on and providing the most stringent limit on from laboratory experiments.
A novel technique for microfabricating alkali atom vapor cells is described in which alkali atoms are evaporated into a micromachined cell cavity through a glass nozzle. A cell of interior volume , containing and a buffer gas, was made in this way and integrated into an atomic clock based on coherent population trapping. A fractional frequency instability of at of integration was measured. The long-term drift of the , , hyperfine frequency of atoms in these cells is below .
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the redefinition of the SI base unit “second,” as they now surpass the performance of cesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of optical clocks, which made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and show that a timescale based on an optical clock can be established that is superior to one based on even the best cesium fountain clocks. The paper also gives further proof of the international consistency of strontium lattice clocks on the accuracy level, which is another prerequisite for a change in the definition of the second.
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to for CSF1 and for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to and , respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.