Michael Stoner

Michael Stoner

Auto-generated profile, based on publicly available information

Michael Stoner

School of Civil and Environmental Engineering and Earth Sciences, Clemson University, United States of America

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Natural Hazards Review
Verified
Journal Article
Closed access
PDF file
MSMichael Stoner
Michael Stoner
WPWeichiang Pang
Weichiang Pang
Research has continued to broaden understanding of tornadoes and their effect on civil infrastructure. Because a significant portion of the losses associated with tornado events impact residential structures, it is appropriate to conduct a risk-based hazard assessment of these structures, particularly those constructed using wood because more than 90% of residential buildings are constructed of wood. In addition, alternatives to light-frame construction, including cross-laminated timber (CLT), provide stronger and more resilient structures. CLT is an engineered wood product made of gluing orthogonal layers of dimensioned lumber to produce panels. In this study, the performance of traditional light-frame construction and CLT archetypes was used to calculate the risk associated with tornadoes. In addition, a tornado hazard database was used to determine the geographic variation in risk associated with residential structures built using CLT and light-frame construction. This risk was quantified in terms of the annual probability of failure, reliability index, and the expected average annual loss. Comparisons of annual probability of failure and reliability index show that, for large portions of the United States, light-frame construction following the current practice exhibits a relatively low reliability. In those same areas, CLT structures designed in accordance with the current code standards and engineering principles exhibited a significantly smaller annual probabilities of failure and larger reliability index. A comparison of cost (direct building and content losses) showed that tornado hazards alone do not make it economically advantageous to build using CLT; however, consideration of additional hazards (e.g., nontornadic wind and earthquake) and other indirect losses (e.g., interruption cost and loss of lives) could make it an alternative worth considering.

11 August 2025 in Environmental Research: Infrastructure and Sustainability
Verified
Journal Article
Open access
Muzan Williams IjeomaMuzan Williams Ijeoma
Muzan Williams Ijeoma
SOSovanroth Ou
Sovanroth Ou
ANAmin Nabati
Amin Nabati
HCHao Chen
Hao Chen
MSMichael Stoner
Michael Stoner
Michael Carbajales-DaleMichael Carbajales-Dale
Michael Carbajales-Dale
The construction sector accounts for approximately 11% of global greenhouse gas emissions, largely due to the production of steel, concrete and aluminum. As global infrastructure investments grow, exceeding $2.9 trillion in the United States alone, there is an urgent need to transition to low-carbon structural systems. Mass timber offers a promising alternative, with lower embodied carbon (EC) and the potential to function as a carbon sink when sustainably sourced. However, conventional mass timber floor systems are limited to spans of 16–25 feet, depending on the selected system and thickness. They often rely on concrete toppings for acoustic and vibration performance, undermining environmental and circularity benefits. Here, we present a novel, all-wood mass timber floor system capable of spanning 40 feet, comparable to steel-framed construction, while achieving carbon negativity, modularity, and disassembly. This is the first timber-based system to combine these structural and sustainability attributes at this span-length. A cradle-to-gate life cycle assessment, aligned with EN 15978 and ISO 14044, quantified the floor system development environmental performance across two proprietary connection strategies: adhesive + screw and sharp plate + screw. Each design sequestered 4,787 kg CO2-eq of biogenic carbon per functional unit, contributing to a net EC of −100.6 and −96.7 kg CO2-eq/m2, respectively, after accounting for construction-stage emissions. The Sharp Plate system also showed lower impacts in smog formation, ecotoxicity, and energy use. Our findings demonstrate the viability of long-span, low-carbon timber floor systems and highlight how connection design can meaningfully influence environmental performance in timber-floor design.

1 November 2025 in Environmental Research Communications
Verified
Journal Article
Open access
Muzan Williams IjeomaMuzan Williams Ijeoma
Muzan Williams Ijeoma
SOSovanroth Ou
Sovanroth Ou
GIGreat William Ijeoma
Great William Ijeoma
MSMichael Stoner
Michael Stoner
BRBrandon Ross
Brandon Ross
Michael Carbajales-DaleMichael Carbajales-Dale
Michael Carbajales-Dale
Mass timber products such as Cross-Laminated Timber (CLT) and Glued Laminated Timber (GLT) are increasingly positioned as low-carbon alternatives to concrete and steel in building construction. While widely cited for their carbon storage potential and reduced embodied emissions, their environmental performance assessment remains fragmented and geographically skewed. Existing environmental assessments disproportionately reflect European production conditions, limiting their relevance to other regions. This study addresses these gaps through a critical review and meta-analysis of 21 peer-reviewed and industry-based Life Cycle Assessments (LCA) and Environmental Product Declarations (EPD) of CLT and GLT production from North America, Oceania, and Japan, harmonized across key parameters such as system boundaries. Results show substantial regional variability in carbon emissions, with the median cradle-to-gate carbon emissions for CLT and GLT produced outside Europe being 52% higher (167 versus 110 kg CO 2 -eq/m 3 ), mainly due to differences in wood species, manufacturing practices, and energy sources. Cumulative energy demand (CED) varies widely, from 800 MJ m −3 to 9602 MJ m −3 , depending on the electricity grid carbon intensity. Product-level differences also emerge: GLT shows markedly higher acidification (+60%), smog formation (+84%), and ozone depletion (+99%), while CLT is associated with higher eutrophication (+71%), freshwater consumption (+20%), and non-hazardous waste generation (+67%). Despite comparable biogenic carbon uptake, regional and process-level factors significantly shape the sustainability profile of mass timber products. This study recommends region-specific LCA guidelines, improved reporting transparency, and regionally differentiated environmental impact benchmarks to support informed procurement and policy. The findings help guide material choices, regulations, and low-carbon strategies for sustainable construction.

1 March 2026 in Advances in Wind Engineering
Verified
Journal Article
Open access
SBSusmita Bhowmik
Susmita Bhowmik
WPWeichiang Pang
Weichiang Pang
MSMichael Stoner
Michael Stoner
DRDavid V. Rosowsky
David V. Rosowsky
AMAndrew Myers
Andrew Myers
BSBenjamin Schafer
Benjamin Schafer

1 November 2025 in Environmental Research Communications
Verified
Journal Article
Open access
Muzan Williams IjeomaMuzan Williams Ijeoma
Muzan Williams Ijeoma
SOSovanroth Ou
Sovanroth Ou
ANAmin Nabati
Amin Nabati
HCHao Chen
Hao Chen
MSMichael Stoner
Michael Stoner
Michael Carbajales-DaleMichael Carbajales-Dale
Michael Carbajales-Dale
This study presents a cradle-to-grave whole-building life cycle assessment (WBLCA) of two functionally equivalent mid-rise commercial office buildings in Atlanta, Georgia: one constructed using mass timber with an all-wood composite floor system (CLT and GLT), and the other using conventional steel and reinforced concrete. Using Tally ® , a Revit-integrated LCA tool, environmental impacts were evaluated across eight categories: global warming, acidification, eutrophication, smog formation, ozone depletion, total primary energy, renewable and non-renewable energy use, and normalized to 1 m 2 of floor area over a 50-year service life. Results showed that the mass timber building required 25% less material mass and achieved a 4.5% reduction in global warming potential (GWP) (2801.12 kg CO 2 -eq/m 2 versus 2975.85 kg CO 2 -eq/m 2 for the steel–concrete system) and 27.9% more renewable energy use. However, timber’s carbon advantage was diminished by conservative end-of-life modeling, assuming 63.5% wood landfilling and 98% steel recycling, which significantly influenced net GWP through Module D credits. Additionally, the mass timber building stored 857,551 tCO 2 -eq in wood components (long-term biogenic carbon storage). The timber structure also exhibited higher eutrophication and acidification impacts, primarily due to emissions from adhesives and chemical treatments. Contribution analysis showed that finishes and non-structural components contributed disproportionately to overall impacts in both systems, illustrating the limitations of focusing solely on structural materials in building LCA. The findings emphasize the need for integrated material strategies, circular end-of-life planning, and regionally grounded modeling to fully realize the environmental potential of wood-based construction.

1 October 2024 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
BBBibek Bhardwaj
Bibek Bhardwaj
WPWeichiang Pang
Weichiang Pang
MSMichael Stoner
Michael Stoner