Rajiv Ramasawmy

Rajiv Ramasawmy

Auto-generated profile, based on publicly available information

Rajiv Ramasawmy

Cardiovascular Branch, Division of Intramural Research National Heart, Lung & Blood Institute, NIH Bethesda Maryland USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
TRToby Rogers
Toby Rogers
KRKanishka Ratnayaka
Kanishka Ratnayaka
JKJaffar M. Khan
Jaffar M. Khan
ASAnnette Stine
Annette Stine
WSWilliam H. Schenke
William H. Schenke
RLRobert J. Lederman
Robert J. Lederman
Quantification of cardiac output and pulmonary vascular resistance (PVR) are critical components of invasive hemodynamic assessment, and can be measured concurrently with pressures using phase contrast CMR flow during real-time CMR guided cardiac catheterization. One hundred two consecutive patients underwent CMR fluoroscopy guided right heart catheterization (RHC) with simultaneous measurement of pressure, cardiac output and pulmonary vascular resistance using CMR flow and the Fick principle for comparison. Procedural success, catheterization time and adverse events were prospectively collected. RHC was successfully completed in 97/102 (95.1%) patients without complication. Catheterization time was 20 ± 11 min. In patients with and without pulmonary hypertension, baseline mean pulmonary artery pressure was 39 ± 12 mmHg vs. 18 ± 4 mmHg (p < 0.001), right ventricular (RV) end diastolic volume was 104 ± 64 vs. 74 ± 24 (p = 0.02), and RV end-systolic volume was 49 ± 30 vs. 31 ± 13 (p = 0.004) respectively. 103 paired cardiac output and 99 paired PVR calculations across multiple conditions were analyzed. At baseline, the bias between cardiac output by CMR and Fick was 5.9% with limits of agreement −38.3% and 50.2% with r = 0.81 (p < 0.001). The bias between PVR by CMR and Fick was −0.02 WU.m2 with limits of agreement −2.6 and 2.5 WU.m2 with r = 0.98 (p < 0.001). Correlation coefficients were lower and limits of agreement wider during physiological provocation with inhaled 100% oxygen and 40 ppm nitric oxide. CMR fluoroscopy guided cardiac catheterization is safe, with acceptable procedure times and high procedural success rate. Cardiac output and PVR measurements using CMR flow correlated well with the Fick at baseline and are likely more accurate during physiological provocation with supplemental high-concentration inhaled oxygen. Clinicaltrials.gov NCT01287026 , registered January 25, 2011.

1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
ACAdrienne E. Campbell-Washburn
Adrienne E. Campbell-Washburn
TRToby Rogers
Toby Rogers
ASAnnette M. Stine
Annette M. Stine
JKJaffar M. Khan
Jaffar M. Khan
RRRajiv Ramasawmy
Rajiv Ramasawmy
RLRobert J. Lederman
Robert J. Lederman
Cardiovascular magnetic resonance (CMR) fluoroscopy allows for simultaneous measurement of cardiac function, flow and chamber pressure during diagnostic heart catheterization. To date, commercial metallic guidewires were considered contraindicated during CMR fluoroscopy due to concerns over radiofrequency (RF)-induced heating. The inability to use metallic guidewires hampers catheter navigation in patients with challenging anatomy. Here we use low specific absorption rate (SAR) imaging from gradient echo spiral acquisitions and a commercial nitinol guidewire for CMR fluoroscopy right heart catheterization in patients. The low-SAR imaging protocol used a reduced flip angle gradient echo acquisition (10° vs 45°) and a longer repetition time (TR) spiral readout (10 ms vs 2.98 ms). Temperature was measured in vitro in the ASTM 2182 gel phantom and post-mortem animal experiments to ensure freedom from heating with the selected guidewire (150 cm × 0.035″ angled-tip nitinol Terumo Glidewire). Seven patients underwent CMR fluoroscopy catheterization. Time to enter each chamber (superior vena cava, main pulmonary artery, and each branch pulmonary artery) was recorded and device visibility and confidence in catheter and guidewire position were scored on a Likert-type scale. Negligible heating (< 0.07°C) was observed under all in vitro conditions using this guidewire and imaging approach. In patients, chamber entry was successful in 100% of attempts with a guidewire compared to 94% without a guidewire, with failures to reach the branch pulmonary arteries. Time-to-enter each chamber was similar (p=NS) for the two approaches. The guidewire imparted useful catheter shaft conspicuity and enabled interactive modification of catheter shaft stiffness, however, the guidewire tip visibility was poor. Under specific conditions, trained operators can apply low-SAR imaging and using a specific fully-insulated metallic nitinol guidewire (150 cm × 0.035” Terumo Glidewire) to augment clinical CMR fluoroscopy right heart catheterization. Clinicaltrials.gov NCT03152773 , registered May 15, 2017.

5 September 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
YYYusuf Samet Yaras
Yusuf Samet Yaras
SSSarp Satir
Sarp Satir
COCagla Ozsoy
Cagla Ozsoy
RRRajiv Ramasawmy
Rajiv Ramasawmy
ACAdrienne E. Campbell-Washburn
Adrienne E. Campbell-Washburn
FDF. Levent Degertekin
F. Levent Degertekin
Objective: The objective of this paper is to introduce an acousto-optic optical fiber sensor for tracking catheter position during interventional magnetic resonance imaging (MRI) to overcome RF induced heating of active markers. Methods: The sensor uses a miniature coil coupled to a piezoelectric transducer, which is in turn mechanically connected to an optical fiber. The piezoelectric transducer converts the RF signal to acoustic waves in the optical fiber over a region including a fiber Bragg grating (FBG). The elastic waves in the fiber modulates the FBG geometry and hence the reflected light in the optical fiber. Since the coil is much smaller than the RF wavelength and the signal is transmitted on the dielectric optical fiber, the sensor effectively reduces RF induced heating risk. Proof of concept prototypes of the sensor are implemented using commercially available piezoelectric transducers and optical fibers with FBGs. The prototypes are characterized in a 1.5T MRI system in comparison with an active tracking marker. Results: Acousto-optical sensor shows linear response with flip angle and it can be used to detect signals from multiple coils for potential orientation detection. It has been successfully used to detect the position of a tacking coil in phantom in an imaging experiment. Conclusion: Acousto-optical sensing is demonstrated for tracking catheters during interventional MRI. Real-time operation of the sensor requires sensitivity improvements like using a narrow band FBG. Significance: Acousto-optics provides a compact solution to sense RF signals in MRI with dielectric transmission lines.

1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
RRRajiv Ramasawmy
Rajiv Ramasawmy
TRToby Rogers
Toby Rogers
MAMiguel A. Alcantar
Miguel A. Alcantar
DMDelaney R. McGuirt
Delaney R. McGuirt
JKJaffar M. Khan
Jaffar M. Khan
DHDaniel A. Herzka
Daniel A. Herzka
The hallmark of heart failure is increased blood volume. Quantitative blood volume measures are not conveniently available and are not tested in heart failure management. We assess ferumoxytol, a marketed parenteral iron supplement having a long intravascular half-life, to measure the blood volume with cardiovascular magnetic resonance (CMR). Swine were administered 0.7 mg/kg ferumoxytol and blood pool T1 was measured repeatedly for an hour to characterize contrast agent extraction and subsequent effect on Vblood estimates. We compared CMR blood volume with a standard carbon monoxide rebreathing method. We then evaluated three abbreviated acquisition protocols for bias and precision. Mean plasma volume estimated by ferumoxytol was 61.9 ± 4.3 ml/kg. After adjustment for hematocrit the resultant mean blood volume was 88.1 ± 9.4 ml/kg, which agreed with carbon monoxide measures (91.1 ± 18.9 ml/kg). Repeated measurements yielded a coefficient of variation of 6.9%, and Bland-Altman repeatability coefficient of 14%. The blood volume estimates with abbreviated protocols yielded small biases (mean differences between 0.01–0.06 L) and strong correlations (r2 between 0.97–0.99) to the reference values indicating clinical feasibility. In this swine model, ferumoxytol CMR accurately measures plasma volume, and with correction for hematocrit, blood volume. Abbreviated protocols can be added to diagnostic CMR examination for heart failure within 8 min.

12 March 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDPierre Daudé
Pierre Daudé
RRRajiv Ramasawmy
Rajiv Ramasawmy
AJAhsan Javed
Ahsan Javed
RLRobert J. Lederman
Robert J. Lederman
KCKelvin Chow
Kelvin Chow
ACAdrienne E. Campbell‐Washburn
Adrienne E. Campbell‐Washburn
Purpose: To develop an inline automatic quality control to achieve consistent diagnostic image quality with subject-specific scan time, and to demonstrate this method for 2D phase-contrast flow MRI to reach a predetermined SNR. Methods: We designed a closed-loop feedback framework between image reconstruction and data acquisition to intermittently check SNR (every 20 s) and automatically stop the acquisition when a target SNR is achieved. A free-breathing 2D pseudo-golden-angle spiral phase-contrast sequence was modified to listen for image-quality messages from the reconstructions. Ten healthy volunteers and 1 patient were imaged at 0.55 T. Target SNR was selected based on retrospective analysis of cardiac output error, and performance of the automatic SNR-driven "stop" was assessed inline. Results: SNR calculation and automated segmentation was feasible within 20 s with inline deployment. The SNR-driven acquisition time was 2 min 39 s +/- 67 s (aorta) and 3 min +/- 80 s (main pulmonary artery) with a min/max acquisition time of 1 min 43 s/4 min 52 s (aorta) and 1 min 43 s/5 min 50 s (main pulmonary artery) across 6 healthy volunteers, while ensuring a diagnostic measurement with relative absolute error in quantitative flow measurement lower than 2.1% (aorta) and 6.3% (main pulmonary artery). Conclusion: The inline quality control enables subject-specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject-specific scan time.

13 September 2024 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
JXJie Xiang
Jie Xiang
RRRajiv Ramasawmy
Rajiv Ramasawmy
FSFelicia Seemann
Felicia Seemann
DPDana C. Peters
Dana C. Peters
ACAdrienne E. Campbell-Washburn
Adrienne E. Campbell-Washburn
There is a growing interest in the development and application of mid-field (0.55T) for cardiovascular magnetic resonance (CMR), including flow imaging. However, aortic flow imaging at 0.55T has limited signal-to-noise ratio (SNR), especially in diastolic phases where there is reduced inflow-driven contrast for spoiled gradient recalled echo (GRE) sequences. The low SNR can limit the accuracy of flow and regurgitant fraction measurements. In this work, we developed a two-dimensional phase contrast (PC) acquisition with balanced steady-state free precession (bSSFP), termed PC-SSFP, for flow imaging and quantification at 0.55T. This PC-SSFP approach precisely nulls the zeroth and first gradient moments at both the echo time (TE) and repetition time, except for the flow-encoded acquisition, for which the first gradient moment at the TE is determined by the velocity encoding. Our proposed sequence was tested in both phantoms and in healthy volunteers (n = 11), to measure aortic flow. In volunteers, both a breath-hold (bh) and a free-breathing (fb) protocol, with averaging to increase SNR, were obtained. Total flow, peak flow, cardiac output, and SNR were compared for PC-SSFP and PC-GRE. Stroke volumes were also measured and compared to planimetry method. In a phantom, SNR was significantly higher using PC-SSFP compared to PC-GRE (25.5 ± 9.6 vs 8.2 ± 2.9), and the velocity measurements agreed well (R = 1.00). In healthy subjects, for both bh and fb protocols, PC-SSFP measured accurate peak flow (fb: R = 0.99, bh: R = 0.96) and cardiac output (fb: R = 0.98, bh: R = 0.88), compared to PC-GRE, accurate stroke volume (fb: R = 0.94, bh: R = 0.97), compared to planimetry measurement, and offered constant high SNR (fb: 28 ± 9 vs 18 ± 6, bh: 24 ± 7 vs 11 ± 3) over the cardiac cycle in 11 subjects. PC-SSFP is a more reliable evaluation tool for aortic flow quantification, when compared to the conventional PC-GRE method at 0.55T, providing higher SNR, and thus potentially more accurate flows.