16 October 2024 in IEEE Transactions on Instrumentation and Measurement
This article presents a novel approach to measuring gas-liquid two-phase flow using a throat-extended Venturi meter (TEVM) based on differential pressure (DP) ratios and fluctuations. The over-reading (OR) and mass quality are the dominant parameters for accurate mass flowrate measurement by a TEVM. First, a liquid OR model is established based on multiple DP ratios, gas-to-liquid density ratio, and liquid densitometric Froude number. This model is solved by integrating a deep neural network (DNN) with an iterative optimization technique. Subsequently, a mass quality model is developed based on multi-DP fluctuations and other related parameters, which can also be solved using a DNN. Finally, the liquid and gas mass flowrates are obtained sequentially from the preceding results. The proposed method addresses the issue of significant errors in the direct solution of the conventional dual-parameter measurements. It utilizes both the static and dynamic features of multi-DP to achieve the simultaneous measurement of gas and liquid mass flowrate using a single TEVM. The experiment was conducted within the a gas flowrate range of 1.3×10 -4 ~5.1×10 -3 kg/s, and a liquid flowrate range of 1.12~3.95 kg/s. The results demonstrate that the relative error for liquid and gas mass flowrate is within ±3% and ±10%, respectively. This indicates that the proposed method is a cost-effective and viable solution for gas-liquid two-phase flow metering using a TEVM, and it can be further adapted to other experimental conditions.
6 February 2026 in IEEE Sensors Journal
This paper presents a photoacoustic spectroscopy (PAS) gas sensor based on a novel π-type Helmholtz photoacoustic cell (πH-PAC) for the first time. The acoustic properties of the πH-PAC were investigated using finite element analysis. The πH-PAC not only enhances the photoacoustic signal by increasing the interaction path between the light source and PAC, but also positions the light source away from the condenser microphone detection point, thereby reducing coherent noise generated by interactions with the window plate during laser incidence. Two distinct excitation methods were designed based on its structure. Compared to the traditional T-type PAC of identical dimensions, the photoacoustic signal was amplified by a factor of 24.76. The πH-PAC based PAS gas sensor exhibited excellent linear concentration response. Allan deviation analysis indicated that the minimum detection limit (MDL) of the πH-PAC-based PAS gas sensor for methane (CH4) detection could be enhanced to 328 ppb when the system average time was set to 1000 s.