Since the initial objective of power system stabiliser (PSS) units and flexible AC transmission system (FACTS) devices is the damping of inter‐area and local oscillations, it is very substantial that the network electromechanical oscillatory modes are identified for tuning the controller of large‐scale interconnected power systems. In this research, a method based on the combination of continuous wavelet transform and Prony algorithm is presented to study low‐frequency electromechanical oscillations of the power system. The coordinated design of PSS and FACTS parameters become a multi‐objective optimisation problem that will be solved using the SPEA II. The residue method is used to improve damping and satisfy the controller constraints of the suggested power systems. Finally, the proposed method of mode estimation and controller design is simulated on the two well‐known test case systems, namely IEEE 2‐area 4‐generator and New England‐New York 68‐bus 16‐generator systems using MATLAB software. The results represent accurate performance and validity of the proposed method to improve oscillation damping, dynamic stability of the power systems.
26 November 2018 in International Transactions on Electrical Energy Systems
Geomagnetically induced currents (GICs) in long high‐voltage transmission lines cause half‐cycle saturation of transformers, malfunction of protective relays, reactive power loss, and voltage instability. This study describes the design for a GIC effects mitigation device (GEMD) that can be installed at a power system autotransformer common node connection to block the flow of GIC DC flux at the cores of the autotransformers. The devices consist of variable resistors, which are controlled by a wide‐area method based on particle swarm optimisation algorithm. The effectiveness of the proposed protective electrical devices is investigated and validated through simulation studies under many operational cases. The test results obtained from 648 cases verify the high performance of GEMD. The proposed method can mitigate the reactive power loss due to GIC in the power system with average improvements by 7.9 and 7.09% over resistive and capacitive blocking devices, respectively.
Nowadays, according to the high penetration of renewable energy sources, the importance of inertia estimation has become more critical than ever. Renewables cause uncertainty and stochasticity and reduce the total inertia of the power system. Therefore, transmission system operators in a changing environment are going to face transient instability increasingly. Thus, a fast and accurate technique for real-time estimation is required. It allows the operator to monitor the system immediately and make an appropriate decision. This paper proposes a real-time inertia estimation method based on the swing equation for a multi-area interconnected power system using the Phasor Measurement Units. The proposed approachs efficiency is validated through time-domain simulation on the two-area four-generator test power system. The numerical results demonstrate the potential and precision of the proposed approach in estimating inertia and confirming the modeling assumptions.