1 February 2018 in Measurement
30 October 2020 in IEEE Transactions on Instrumentation and Measurement
This paper presents a novel, low-cost and smart design setup (plug and play) to measure the needle attachment force of surgical suture in order to check attachment quality and verify the surgical suture manufacturing standards. The proposed design uses needle gripper, tactile sensor, suture gripper (connected via motorized lead screw) and infrared sensor, which is mounted over a linear guide. The ends of surgical suture (comprising of needle and thread) are attached between needle gripper and suture gripper, respectively. The motorized suture gripper creates stress on the attachment point of needle and thread of surgical suture, whose force is measured by a tactile sensor followed by the application of Kalman filtering for precise estimation and (then) calibration. An infrared sensor is used to track suture gripper position to stay within the displacement limits and to obtain the characteristic force-position profile as well. In addition, the two interactive graphical interfaces (an OLED and LABVIEW-based installed on windows) are embedded on the device to feature user friendly interface. Moreover, for quick documentation and record, thermal printer is installed inside the setup, which provides the time-stamped summary of different sutures being tested. Both the sensors, force filtering, OLED and thermal printer are communicated by advanced ATmega2560 controller. In order to validate the significance of the proposed design setup; (i) Solidworks simulation for motion study is conducted; (ii) real experimental measurements of pull and destructive forces for different gauges of sutures are performed and verified with standards; (iii) comparisons with other relevant devices/approaches in terms of (a) being cost-effective and (b) showing optimized methodology are also presented.
1 January 2008 in IFAC Proceedings Volumes
Alignment is the process whereby the orientation of the axes of an inertial navigation system is determined with respect to the reference system. In this paper, the initial alignment error equations of the strapdown inertial navigation system (SINS) with large initial azimuth error have been derived with inclusion of nonlinear characteristics. The second order central difference filter (CDF2) has been used for solution of the alignment problem. Simulations have been carried out to validate and corroborate the stationary alignment case employing a strapdown inertial measurement unit (SIMU). A performance comparison between the extended Kalman filter (EKF), the unscented Kalman filter (UKF) and the CDF demonstrate that the accuracy of attitude error estimation using the CDF2 is better than that of using the EKF or the UKF.