1 September 1994 in Physical Review D
We present the results of a search for the top quark in 19.3 of p¯p collisions at √s =1.8 TeV. The data were collected at the Fermilab Tevatron collider using the Collider Detector at Fermilab (CDF). The search includes standard model tt¯ decays to final states eeνν¯, eμνν¯, and μμνν¯ as well as e+ν+jets or μ+ν+jets. In the (e,μ)+ν+jets channel we search for b quarks from t decays via secondary vertex identification and via semileptonic decays of the b and cascade c quarks. In the dilepton final states we find two events with a background of 0. events. In the e,μ+ν+jets channel with a b identified via a secondary vertex, we find six events with a background of 2.3±0.3. With a b identified via a semileptonic decay, we find seven events with a background of 3.1±0.3. The secondary vertex and semileptonic-decay samples have three events in common. The probability that the observed yield is consistent with the background is estimated to be 0.26%. The statistics are too limited to firmly establish the existence of the top quark; however, a natural interpretation of the excess is that it is due to tt¯ production. We present several cross-checks. Some support this hypothesis; others do not. Under the assumption that the excess yield over background is due to tt¯, constrained fitting on a subset of the events yields a mass of 174± GeV/ for the top quark. The tt¯ cross section, using this top quark mass to compute the acceptance, is measured to be 13. pb.
1 October 1997 in Physical Review D
A strong signal for double parton (DP) scattering is observed in a sample of data from the CDF experiment at the Fermilab Tevatron. In DP events, two separate hard scatterings take place in a single collision. We isolate a large sample of data of which 53% are found to be DP. The process-independent parameter of double parton scattering, is obtained without reference to theoretical calculations by comparing observed DP events to events with hard scatterings in separate collisions. The result represents a significant improvement over previous measurements, and is used to constrain simple models of parton spatial density. The Feynman dependence of is investigated and none is apparent. Further, no evidence is found for kinematic correlations between the two scatterings in DP events.
11 July 1994 in Physical Review Letters
We summarize a search for the top quark with the Collider Detector at Fermilab (CDF) in a sample of p¯p collisions at √s =1.8 TeV with an integrated luminosity of 19.3 . We find 12 events consistent with either two W bosons, or a W boson and at least one b jet. The probability that the measured yield is consistent with the background is 0.26%. Though the statistics are too limited to establish firmly the existence of the top quark, a natural interpretation of the excess is that it is due to tt¯ production. Under this assumption, constrained fits to individual events yield a top quark mass of 174± GeV/. The tt¯ production cross section is measured to be 13. pb.
28 July 1997 in Physical Review Letters
We present a study of and production in collisions, at with the CDF detector at Fermilab. The and mesons are reconstructed using their decay modes. We have measured the inclusive production cross section for both mesons as a function of their transverse momentum in the central region, . We also measure the fraction of these events originating from hadrons. We thus extract individual cross sections for and mesons from -quark decays and prompt production. We find a large excess (approximately a factor of 50) of direct production compared with predictions from the color singlet model.
22 October 2020 in Physics in Medicine & Biology
Since the seventies, positron emission tomography (PET) has become an invaluable medical molecular imaging modality with an unprecedented sensitivity at the picomolar level, especially for cancer diagnosis and the monitoring of its response to therapy. More recently, its combination with x-ray computed tomography (CT) or magnetic resonance (MR) has added high precision anatomic information in fused PET/CT and PET/MR images, thus compensating for the modest intrinsic spatial resolution of PET. Nevertheless, a number of medical challenges call for further improvements in PET sensitivity. These concern in particular new treatment opportunities in the context personalized (also called precision) medicine, such as the need to dynamically track a small number of cells in cancer immunotherapy or stem cells for tissue repair procedures. A better signal-to-noise ratio (SNR) in the image would allow detecting smaller size tumours together with a better staging of the patients, thus increasing the chances of putting cancer in complete remission. Moreover, there is an increasing demand for reducing the radioactive doses injected to the patients without impairing image quality. There are three ways to improve PET scanner sensitivity: improving detector efficiency, increasing geometrical acceptance of the imaging device and pushing the timing performance of the detectors. Currently, some pre-localization of the electron-positron annihilation along a line-of-response (LOR) given by the detection of a pair of annihilation photons is provided by the detection of the time difference between the two photons, also known as the time-of-flight (TOF) difference of the photons, whose accuracy is given by the coincidence time resolution (CTR). A CTR of about 10 picoseconds FWHM will ultimately allow to obtain a direct 3D volume representation of the activity distribution of a positron emitting radiopharmaceutical, at the millimetre level, thus introducing a quantum leap in PET imaging and quantification and fostering more frequent use of 11 C radiopharmaceuticals. The present roadmap article toward the advent of 10 ps TOF-PET addresses the status and current/future challenges along the development of TOF-PET with the objective to reach this mythic 10 ps frontier that will open the door to real-time volume imaging virtually without tomographic inversion. The medical impact and prospects to achieve this technological revolution from the detection and image reconstruction point-of-views, together with a few perspectives beyond the TOF-PET application are discussed.
1 June 1993 in Physical Review D
Kinematic properties of four-jet events produced in collisions at TeV have been studied using data with an integrated luminosity of 325 collected using the Collider Detector at Fermilab during the 1988-1989 Fermilab Collider run. The individual jet spectra and the angles between each jet pair are compared to the predictions of leading-order quantum chromodynamics for the double gluon bremsstrahlung process and good agreement is observed. In addition, a search for double parton scattering has been undertaken using variables sensitive to the topology of four-jet events. A small double parton content provides the best description of the data. We find , where represents the number of events attributed to each process. We measure nb for jets having GeV/c in the pseudorapidity interval .