1 September 2021 in Journal of Surgical Education
JSJessica R. Santos-Parker
+1
1 January 2020 in The Annals of Thoracic Surgery
Left ventricular outflow tract pseudoaneurysm is a potentially fatal complication after aortic root replacement. Challenges surrounding multiple reoperations on the aortic root include sternal reentry, bleeding, valve positioning, compression of coronary arteries, and navigating concomitant interventions. We present a 27-year-old patient with mechanical valves in the aortic and mitral positions and a left main coronary artery drug-eluting stent for left main compression after being diagnosed with rheumatic heart disease at age 16. She underwent a fourth redo modified Bentall procedure with a homemade mechanical composite graft for the contained rupture of an left ventricular outflow tract pseudoaneurysm.
1 September 2026 in Open Forum Infectious Diseases
Background: Despite advances in echocardiography, the definitive diagnosis of prosthetic valve endocarditis (PVE) remains difficult. 18F-fluorodeoxyglucose (chemical name 2-deoxy-2-[18F]fluro-D-glucose) positron emission tomography (PET) shows promise with improved sensitivity. Our study explored the effects of PET findings on the diagnosis of PVE and patient management decisions. Method: Between 2016 and 2022, 140 patients underwent PET to evaluate suspected left-sided PVE, resulting in 93 patients with positive PET (+PET) and 47 patients with negative PET. Patients were classified as definite, possible, or rejected PVE according to the 2023 Duke-International Society for Cardiovascular Infectious Diseases guidelines, initially excluding and then including PET results. We evaluated the association between PET results and clinical outcomes such as duration of antibiotics, performance of cardiac surgery within 3 months, and long-term mortality. A qualitative analysis of medical decision-making was performed. Results: Demographics were similar between groups. patients with +PET had higher C-reactive protein levels (9.8 vs 3.1 mg/L, P = .001) and were more likely to have positive blood culture and echocardiographic findings. The addition of PET significantly increased the diagnosis of definite endocarditis (46%–63%, P < .001). A +PET was positively associated with ongoing use of antibiotics after 3 months (odds ratio [OR] 3.93, P = .002) and surgical management (OR 5.99, P = .008). Based on qualitative review of medical decision-making, PET influenced management in 88 patients (63%), supporting longer duration of antibiotics in 22%, surgical management in 8.6%, and shorter duration of antibiotics in 11% of patients. Conclusions: Positron emission tomography results, when incorporated into multidisciplinary discussion, aided in a more definitive diagnosis of PVE and influenced management in the majority of patients.
15 January 2025 in European Heart Journal - Case Reports
Background: While echocardiography and cardiac positron emission tomography (PET) can aid in the diagnosis of prosthetic valve endocarditis (PVE), post-operative changes can lead to false-positive imaging findings. We report a case of a patient with an aortic valve prosthesis with remnant BioGlue deposits mimicking a para-valvular abscess on imaging in the setting of suspected PVE. Case summary: A 67-year-old man presented with 2 days of fever, chills, and altered mentation. He had a history of two prior aortic root replacements—19 and 4 years prior to his presentation. He had blood cultures that were persistently positive for Pseudomonas aeruginosa. Initial transoesophageal echocardiogram (TEE) was notable for a thickening of the posterior aortic root thought to be consistent with post-surgical changes. Cardiac PET showed significant uptake around the prosthetic aortic valve, concerning for a para-valvular abscess. However, given the patient’s high risk for re-do surgery, clearance of blood cultures, and preserved valve function, our multi-disciplinary endocarditis team (MET) recommended non-surgical management and close follow-up. After 6 weeks of appropriate antibiotics, a TEE demonstrated concern for an evolving para-valvular abscess. The MET performed extensive review of his prior surgical interventions and cardiac imaging, revealing the previous use of surgical BioGlue and stability in the aortic root on imaging, consistent with non-infectious post-surgical changes, and conservative management was recommended. Discussion: Thorough review of prior interventions and serial imaging in patients with suspected PVE through a multi-disciplinary team approach is essential in elucidating the complete, often complex, clinical picture and recommending the most appropriate management.