Background: Leukocyte parameters are predicted to be affected in patients with metabolic syndrome (MetS). We conducted a systematic review and meta-analysis to study the association between white blood cell parameters (WBC) in people with and without MetS. Methods: PubMed, EMBASE, Scopus and Cochrane Library databases were searched according to the study protocol. The standardized mean difference (SMD) and 95% confidence intervals (CI) of leukocyte markers between individuals with and without MetS were pooled using an inverse variance model. Additionally, a subgroup analysis by sex was performed where possible. Methodological quality assessment was conducted using the Newcastle-Ottawa scale (NOS) for observational studies and the Cochrane Risk of Bias tool 2.0 for Randomized Controlled Trials (RCTs). Results: Of 6068 articles identified, 63 were eligible for the study. Compared to controls, individuals with MetS showed significantly higher concentrations of total leukocyte count (SMD [95% CI]: 0.60 [0.55–0.65]; P < .00001; I2 = 100%), neutrophil counts (0.32 [0.28–0.37]; P < .00001; I2 = 99%), lymphocyte counts (0.15 [0.07–0.23]; P = .0004; I2 = 100%), basophil counts (0.01 [0.00–0.02]; P = .02; I2 = 98%), monocyte counts (0.05 [0.02–0.09]; P = .003; I2 = 99%), and neutrophil-to-lymphocyte ratio (0.24 [0.15–0.33]; P < .00001; I2 = 98%). There were no significant differences in the eosinophil count (0.02 [−0.01 to 0.05]; P = .19; I2 = 96%) and monocyte-to-lymphocyte ratio (0.06 [−0.05 to 0.17]; P = .27; I2 = 100%) between patients with and without MetS, however, the lymphocyte-to-monocyte ratio (0.52 [−0.81 to −0.23]; P = .0005; I2 = 52%) tended to be significantly lower in patients with MetS. Conclusion: Biomarkers such as total leukocyte count, neutrophil count, lymphocyte count, basophil count, monocyte count and neutrophil-to-lymphocyte ratio are associated with higher levels in patients in MetS and thus can potentially be used for early detection of MetS.
Using data collected with the CLEO II detector at the Cornell Electron Storage Ring, we present new measurements of the branching fractions for and . These results are combined with other CLEO measurements to extract the ratios of isospin amplitudes and phase shifts for and .
Using of data accumulated at the by the CLEO-II detector, corresponding to pairs, we have searched for the color-suppressed hadronic decay processes where is a light neutral meson η, or ω. The mesons are reconstructed in and the mesons in and decay modes. No obvious signal is observed. We set 90% C.L. upper limits on these modes, varying from for to for
The CLEO II detector at the storage ring CESR has been used to search for two-photon production of the decaying into . No evidence for a signal is found in of data and a 95% C.L. upper limit on of 2.5 eV is set. If this result is combined with the BES Collaboration's measurement of in radiative decay and the recent CLEO result for , a C.L. lower limit on the stickiness of 102 is obtained. This result for the stickiness provides further support for a substantial neutral parton content in the .
We use data collected by the CLEO II detector at the Cornell Electron Storage Ring (CESR) to search for (nonresonant) decays, where can be either , or . We see no evidence for signals and set upper limits on the branching fractions in the range . If observed, these decays may display CP violating asymmetries.