2 July 2020 in IEEE Transactions on Power Electronics
This paper proposes modeling and two controller design techniques for a Triple Active Bridge (TAB) three-port DC-DC converter comprising of Fuel Cell (FC), Battery, and load. The sources are integrated, employing boost interleaved full-bridge converters in order to get smoother source current profile. The converter is a nonlinear multi-input multi-output (MIMO) system with a large number of control variables. Moreover, a high degree of coupling among the control variables makes its modeling and control system design quite cumbersome and complex. To overcome the complexity of analysis in a higher order system like TAB, a generalized frequency-domain modeling technique is introduced in this paper. A new decoupling matrix-based proportional-integral controller design method is also proposed. It reduces the design complexity and improves the system dynamic performance (lower settling time, overshoot/undershoot in the controlled variables) in comparison to similar three-port converters reported in the literature. Further, the performance of the proposed controller is compared by simulation with another popular MIMO system controller design technique, namely the state feedback control. A 1kW laboratory prototype is built and tested to verify the system performance during dynamic load changes, source current variation, and battery charging/discharging operation.
26 February 2020 in IEEE Transactions on Industrial Electronics
Distribution lines are generally protected by overcurrent relays. With the integration of inverter-interfaced solar photovoltaic (PV) plant having current limiting feature, fault current seen by the relay on PV-side of that feeder becomes comparable to load current. Conventional overcurrent relaying principle is not suitable for distribution line protection. Distance relay may be a viable option for protection of distribution lines connecting solar PV plant. However, the positive and negative sequence source impedances of PV plant depend on inverter controller which results in limited performance of fixed setting distance relay. This paper proposes an adaptive distance relay setting to protect distribution line connecting PV plant, using prefault voltage and current data at relaying point. The method calculates the positive and negative sequence PV source impedances for boundary setting of distance relay at PV-side. The proposed trip boundary is modified adaptively with the change in prefault conditions of PV plant. Performance of proposed method is tested for different control strategies and operating capacities of PV plant and variation in grid source impedance on a 34-bus distribution system. Real-time application of the proposed method is validated in hardware-in-loop using OPALRT simulators with IEC 61850 as communication protocol and found to be accurate.
5 March 2020 in IEEE Transactions on Power Electronics
As grid codes evolve, inverter-interfaced renewable generation may be required to take greater responsibility for grid support. It may be obliged to source a large current during a short-circuit fault in the grid and provide large dynamic reactive power, beyond the inverter rating, for voltage recovery after the fault clearance. In this sense, the inverter-interfaced generating system would behave more similarly to a conventional synchronous machine. This is not yet mandatory but current technology cannot readily support it if required in the future, because the power semiconductors would overheat unless they are drastically de-rated. This study proposes a method to increase the power semiconductor's transient thermal capacity, and hence its short-term over-current capability, by integrating a phase-change material inside the power semiconductor module. Experiment and thermodynamic simulation across different materials are used to illustrate the feasibility of the concept and the factors that should be considered in such a design. The study shows that 1.5 p.u. (per unit) over-current could be achieved for 30 s, which is typical of synchronous generators; and 3.0 p.u. fault current could be achieved for 3 s. A custom-made 1200 V, 50 A IGBT half-bridge module integrating a liquid metal as the phase change material is compared with a conventional commercially-available module. A validated simulation model is then used to further evaluate the proposal, regarding a 1700 V, 1000 A IGBT module for use in a wind turbine.
24 August 2021 in IEEE Transactions on Power Systems
This manuscript presents a novel control architecture for the E-STATCOM (STATCOM integrated with Energy Storage System (ESS)) that is common for both the Stand-Alone (SA) as well as the Grid-Connected (GC) modes of operation of a microgrid operating under unbalanced conditions. The proposed control architecture fulfils the aim of regulating the E-STATCOM in such a manner so as to smoothen the power fluctuations of a nearby renewable energy source (solar, wind, etc) and also to maintain the voltage and frequency of the Point of Common Coupling (PCC) within the normal range of operation. Hence, the resultant real power injected by the renewable energy source along with the E-STATCOM is constant in magnitude, irrespective of whether the microgrid is in the GC or the SA mode of operation. Dynamically varying limits are introduced to provide inherent VSC overcurrent protection. In order to illustrate the performance of these control architectures, a model of the IEEE 34 node power distribution network that is being supplied by a solar Photo-Voltaic (PV) Distributed Generation (DG) unit, a wind DG unit and two identical E-STATCOMs (for compensating the power fluctuations from the PV and wind DG units) has been considered for study in PSCAD/EMTDC.
11 November 2019 in IEEE Transactions on Power Delivery
This manuscript develops a unified control structure for Distributed Generation (DG) units based on Voltage Source Converters considering unbalanced and non-linear operating conditions. This control structure works for both the Islanded and the Grid-connected modes of operation of the Micro-Grid (MG). The objective of this control scheme is to regulate the line currents of the DG unit in such a manner that the voltage at the Point of Common Coupling (PCC) remains balanced despite the line currents of the DG unit being unbalanced and distorted. Multiple adaptive P-R controllers have been proposed for the current control loop of the Voltage Source Converter (VSC). These controllers have been implemented with resettable integrators so as to limit the DC components in the post fault current of the VSC. The Battery Energy Storage System (BESS) is interfaced to the DC link of the VSC through bi-directional dc-dc converters. An improved control structure for the bi-directional dc-dc converter has been developed. The effectiveness of these control structures have been presented and tested in PSCAD/EMTDC in an IEEE 34 node distribution system model being fed by two identical DG units.
23 December 2022 in IEEE Transactions on Sustainable Energy
This paper proposes a control strategy for enabling voltage fault ride-through (VFRT) operation with adaptive dynamic voltage support (DVS) scheme using the energy storage in a microgrid. Firstly, the condition for maximum DVS from the microgrid is presented and its dependency on the parameters of the equivalent network seen by the microgrid is elucidated. Considering the impediments associated with the real-time parameter estimation during the short-term voltage disturbances, reference current signals based on the extreme voltage tracking algorithm are proposed in this paper to achieve an adaptive DVS irrespective of the varying system conditions. Secondly, a control strategy is proposed to enable the energy storage-based VFRT operation of a microgrid. Thirdly, a unique methodology of sizing the energy storage for VFRT operation is presented considering the grid code requirements, equivalent network characteristics, and the maximum current rating of the power electronic interface with the grid. The proposed control strategy is validated through real-time digital simulation case studies for low-voltage, high-voltage, and multiple-fault scenarios. The scalability of the proposed approach is illustrated using the CIGRE distribution test network.