9 March 2026 in IEEE Transactions on Applied Superconductivity
PAX (antiProtonic Atom X-ray spectroscopy) is an experiment that aims to test strong-field quantum elec trodynamics (QED) effects by performing high-precision X ray spectroscopy of antiprotonic atoms. PAX will use a low energy antiproton beam provided by the Extra Low Energy Antiproton (ELENA) ring at the European Organization for Nuclear Research (CERN) to create antiprotonic atoms. A superconducting transition-edge sensor (TES) spectrometer will be used to measure the energy of transitions between circular Rydberg states in these atoms. The energy range of interest for the experiment spans 50 keV to 250 keV, and the desired precision for measuring the centroids of the emission lines is 10−5. The spectrometer for PAX is intended to have four 96-pixel TES arrays and will be read out with a microwave superconducting quantum interference device (SQUID) multiplexer. As a step towards building the full instrument, we built a scaled-down version of the spectrometer that was installed at the TEst Line for Machine And Antimatter eXperiments (TELMAX) facility at ELENA in April 2025. The purpose of this deployment was to make an observation of X-ray emission by antiprotonic atoms and to better understand the effect of the pionic charged particle background due to antiproton annihilation on the per formance of the TES array. This pilot spectrometer had an array of 60 TES pixels in a compact adiabatic demagnetization refrigerator (ADR) cryostat. The sensors were read out with a microwave SQUID multiplexer. Each pixel consisted of a molybdenum/gold bilayer TES with a co-planar gold “landing pad” for a bulk tin absorber that was attached by an epoxy joint. We discuss the design of the TES pixels, the microwave SQUID readout, and the cryogenic platform. Finally, we present calibration data obtained at TELMAX using radioactive sources to assess the performance of the spectrometer in the antiproton beam-off condition.
17 February 2024 in arXiv
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.