2 May 2018 in Scientific Reports
Animal models of allergic airways inflammation are useful tools in studying the pathogenesis of asthma and potential therapeutic interventions. The different allergic airways inflammation models available to date employ varying doses, frequency, duration and types of allergen, which lead to the development of different features of asthma; showing varying degrees of airways inflammation and hyper-responsiveness (AHR) and airways remodeling. Models that also exhibit airway remodeling, a key feature of asthma, in addition to AHR and airway inflammation typically require 5–12 weeks to develop. In this report, we describe a 4-week mouse model of house dust mite (HDM)-induced allergic airways inflammation, and compare the phenotypic features of two different doses of HDM exposures (10 µg and 25 µg) for 5 days/week with a well-characterized 8-week chronic HDM model. We found that 4 weeks of intranasal HDM (25 µg in 35 µl saline; 5 days/week) resulted in AHR, airway inflammation and airway remodeling that were comparable to the 8-week model. We conclude that this new 4-week HDM model is another useful tool in studies of human asthma that offers advantages of shorter duration for development and decreased costs when compared to other models that require longer durations of exposure (5–12 weeks) to develop.
5 October 2021 in European Respiratory Review
175 years have elapsed since John Hutchinson introduced the world to his version of an apparatus that had been in development for nearly two centuries, the spirometer. Though he was not the first to build a device that sought to measure breathing and quantify the impact of disease and occupation on lung function, Hutchison coined the termsspirometerandvital capacitythat are still in use today, securing his place in medical history. As Hutchinson envisioned, spirometry would become crucial to our growing knowledge of respiratory pathophysiology, from Tiffeneau and Pinelli's work on forced expiratory volumes, to Fry and Hyatt's description of the flow–volume curve. In the 20th century, standardization of spirometry further broadened its reach and prognostic potential. Today, spirometry is recognized as essential to respiratory disease diagnosis, management and research. However, controversy exists in some of its applications, uptake in primary care remains sub-optimal and there are concerns related to the way in which race is factored into interpretation. Moving forward, these failings must be addressed, and innovations like Internet-enabled portable spirometers may present novel opportunities. We must also consider the physiologic and practical limitations inherent to spirometry and further investigate complementary technologies such as respiratory oscillometry and other emerging technologies that assess lung function. Through an exploration of the storied history of spirometry, we can better contextualize its current landscape and appreciate the trends that have repeatedly arisen over time. This may help to improve our current use of spirometry and may allow us to anticipate the obstacles confronting emerging pulmonary function technologies.
15 June 2020 in American Journal of Respiratory and Critical Care Medicine
TPThe Toronto Lung Transplant Programme
The Toronto Lung Transplant Programme
+11
Rationale: Acute cellular rejection (ACR) is common during the initial 3 months after lung transplant. Patients are monitored with spirometry and routine surveillance transbronchial biopsies. However, many centers monitor patients with spirometry only because of the risks and insensitivity of transbronchial biopsy for detecting ACR. Airway oscillometry is a lung function test that detects peripheral airway inhomogeneity with greater sensitivity than spirometry. Little is known about the role of oscillometry in patient monitoring after a transplant. Objectives: To characterize oscillometry measurements in biopsy-proven clinically significant (grade ≥2 ACR) in the first 3 months after a transplant. Methods: We enrolled 156 of the 209 double lung transplant recipients between December 2017 and March 2019. Weekly outpatient oscillometry and spirometry and surveillance biopsies at Weeks 6 and 12 were conducted at our center. Measurements and Main Results: Of the 138 patients followed for 3 or more months, 15 patients had 16 episodes of grade 2 ACR (AR2) and 44 patients had 64 episodes of grade 0 ACR (AR0) rejection associated with stable and/or improving spirometry. In 15/16 episodes of AR2, spirometry was stable or improving in the weeks leading to transbronchial biopsy. However, oscillometry was markedly abnormal and significantly different from AR0 (P < 0.05), particularly in integrated area of reactance and the resistance between 5 and 19 Hz, the indices of peripheral airway obstruction. By 2 weeks after biopsy, after treatment for AR2, oscillometry in the AR2 group improved and was similar to the AR0 group. Conclusions: Oscillometry identified physiological changes associated with AR2 that were not discernible by spirometry and is useful for graft monitoring after a lung transplant.
23 December 2021 in European Respiratory Journal
Background: Chronic lung allograft dysfunction (CLAD) is the principal cause of graft failure in lung transplant recipients and prognosis depends on CLAD phenotype. We used a machine learning computed tomography (CT) lung texture analysis tool at CLAD diagnosis for phenotyping and prognostication compared with radiologist scoring.Methods: This retrospective study included all adult first double lung transplant patients (January 2010–December 2015) with CLAD (censored December 2019) and inspiratory CT near CLAD diagnosis. The machine learning tool quantified ground-glass opacity, reticulation, hyperlucent lung and pulmonary vessel volume (PVV). Two radiologists scored for ground-glass opacity, reticulation, consolidation, pleural effusion, air trapping and bronchiectasis. Receiver operating characteristic curve analysis was used to evaluate the diagnostic performance of machine learning and radiologist for CLAD phenotype. Multivariable Cox proportional hazards regression analysis for allograft survival controlled for age, sex, native lung disease, cytomegalovirus serostatus and CLAD phenotype.Results: 88 patients were included (57 bronchiolitis obliterans syndrome (BOS), 20 restrictive allograft syndrome (RAS)/mixed and 11 unclassified/undefined) with CT a median 9.5 days from CLAD onset. Radiologist and machine learning parameters phenotyped RAS/mixed with PVV as the strongest indicator (area under the curve (AUC) 0.85). Machine learning hyperlucent lung phenotyped BOS using only inspiratory CT (AUC 0.76). Radiologist and machine learning parameters predicted graft failure in the multivariable analysis, best with PVV (hazard ratio 1.23, 95% CI 1.05–1.44; p=0.01).Conclusions: Machine learning discriminated between CLAD phenotypes on CT. Both radiologist and machine learning scoring were associated with graft failure, independent of CLAD phenotype. PVV, unique to machine learning, was the strongest in phenotyping and prognostication.
8 April 2022 in BMJ Open Respiratory Research
Background: Markers of idiopathic pulmonary fibrosis (IPF) severity are based on measurements of forced vital capacity (FVC), diffusing capacity (DLCO) and CT. The pulmonary vessel volume (PVV) is a novel quantitative and independent prognostic structural indicator derived from automated CT analysis. The current prospective cross-sectional study investigated whether respiratory oscillometry provides complementary data to pulmonary function tests (PFTs) and is correlated with PVV. Methods: From September 2019 to March 2020, we enrolled 89 patients with IPF diagnosed according to international guidelines. We performed standard spectral (5–37 Hz) and novel intrabreath tracking (10 Hz) oscillometry followed by PFTs. Patients were characterised with the gender-age-physiology (GAP) score. CT images within 6 months of oscillometry were analysed in a subgroup (26 patients) using automated lung texture analysis. Correlations between PFTs, oscillometry and imaging variables were investigated using different regression models. Findings: The cohort (29F/60M; age=71.7±7.8 years) had mild IPF (%FVC=70±17, %DLCO=62±17). Spectral oscillometry revealed normal respiratory resistance, low reactance, especially during inspiration at 5 Hz (X5in), elevated reactance area and resonance frequency. Intrabreath oscillometry identified markedly low reactance at end-inspiration (XeI). XeI and X5in strongly correlated with FVC (r2=0.499 and 0.435) while XeI was highly (p=0.004) and uniquely correlated with the GAP score. XeI and PVV exhibited the strongest structural-functional relationship (r2=0.690), which remained significant after adjusting for %FVC, %DLCO and GAP score. Interpretation: XeI is an independent marker of IPF severity that offers additional information to standard PFTs. The data provide a cogent rationale for adding oscillometry in IPF assessment.
6 October 2022 in Frontiers in Physiology
Background: Chronic lung allograft dysfunction (CLAD) is the major cause of death beyond 2 years after lung transplantation and develops in 50% of all patients by 5 years post-transplant. CLAD is diagnosed on the basis of a sustained drop of 20% for at least 3 months in the forced expiratory volume (FEV1), compared to the best baseline value achieved post-transplant. CLAD presents as two main phenotypes: bronchiolitis obliterans syndrome (BOS) is more common and has better prognosis than restrictive allograft syndrome (RAS). Respiratory oscillometry is a different modality of lung function testing that is highly sensitive to lung mechanics. The current study investigated whether spectral and intrabreath oscillometry can differentiate between CLAD-free, BOS- and RAS-CLAD at CLAD onset, i.e., at the time of the initial 20% drop in the FEV1.Methods: A retrospective, cross-sectional analysis of 263 double lung transplant recipients who underwent paired testing with oscillometry and spirometry at the Toronto General Pulmonary Function Laboratory from 2017 to 2022 was conducted. All pulmonary function testing and CLAD diagnostics were performed following international guidelines. Statistical analysis was conducted using multiple comparisons.Findings: The RAS (n = 6) spectral oscillometry pattern differs from CLAD-free (n = 225) by right-ward shift of reactance curve similar to idiopathic pulmonary fibrosis whereas BOS (n = 32) has a pattern similar to obstructive lung disease. Significant differences were found in most spectral and intrabreath parameters between BOS, RAS, and time-matched CLAD-free patients. Post-hoc analysis revealed these differences were primarily driven by BOS instead of RAS. While no differences were found between CLAD-free and RAS patients with regards to spectral oscillometry, the intrabreath metric of reactance at end-inspiration (XeI) was significantly different (p < 0.05). BOS and RAS were differentiated by spectral oscillometry measure R5, and intrabreath resistance at end expiration, ReE (p < 0.05 for both).Conclusion: Both spectral and intrabreath oscillometry can differentiate BOS-CLAD from CLAD-free states while intrabreath oscillometry, specifically XeI, can uniquely distinguish RAS-CLAD from CLAD-free. Spectral and intrabreath oscillometry offer complementary information regarding lung mechanics in CLAD patients to help distinguish the two phenotypes and could prove useful in prognostication.