Coffee is one of the most widely consumed beverages in the world. It contains many bioactive compounds, including chlorogenic acid which possesses various biological properties. In this study, in order to determine concentration of chlorogenic acid in green coffee, a reverse-phase rapid resolution liquid chromatography (RP-RRLC) method with diode-array detection (DAD) was developed. Successful separation was achieved on a Poroshell 120 EC-C18 (50 mm × 3 mm; 2.7 μm) column using acetonitrile–water with 1% phosphoric acid (10:90, v/v) as a mobile phase, at a flow rate of 1 mL/min, and with UV detection at 325 nm. The identification was made with comparison of the retention time of pure analytical standard with the retention time of chlorogenic acid in the analyzed samples. The developed method was validated using the following parameters: linearity, sensitivity, selectivity, precision, and accuracy. Excellent linearity over the range 12.33–143.50 μg/mL was achieved with R2 values greater than 0.99. The intra-day precision was validated with the %RSD values, which confirmed that the method for determination of chlorogenic acid was repeatable. The mean recovery rate of the method ranged between 97.87% and 106.67% with %RSD values lower than 1%. The limit of detection and limit of quantification values under the used chromatographic conditions were 0.29 and 0.96 pg, respectively. This method was successfully employed for quantitative determination of chlorogenic acid in green coffee samples.
Reverse-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous determination of sodium benzoate and potassium sorbate in beverages was developed using high speed column. The simple and rapid reverse-phase method for quantitative determination of both preservatives was established on LiChroCART® Purospher STAR RP-18e (30 mm × 4 mm; 3 μm) column, mobile phase consisted of acetonitrile-phosphate buffer (pH = 3.5) in volume ratio of 8:92 (v/v), flow rate of 1 mL min−1, ultraviolet (UV) detection at 195 nm for sodium benzoate and 260 nm for potassium sorbate, and constant column temperature at 25 °C. Linearity, precision, accuracy, limit of quantification (LOQ), and limit of detection (LOD) were tested for method validation. Linearity range for sodium benzoate was 6.04–200.27 mg L−1 (R2 = 0.999) while, for potassium benzoate (R2 = 0.999), 12.19–406.36 mg L−1. The RSD values ≤1.03% demonstrate excellent intra-day precision. LOD for sodium benzoate and potassium sorbate was 0.004 and 0.003 mg L−1, while LOQ was 0.012 and 0.009 mg L−1, respectively. This method was applied for quantitative determination of investigated preservatives in beverages which were taken from Macedonian markets.
A new rapid and simple method for simultaneous determination of azoxystrobin, acetamiprid and metalaxyl in tomatoes has been developed and validated. The separation and quantification of...
This paper presents a new, simple, precise, and accurate rapid resolution liquid chromatography (RRLC) method for determination of an active ingredient malathion in the pesticide formulation. The analysis was performed on a Poroshell EC 120-C18 (50 mm × 3 mm, 2.7 μm) analytical column using isocratic elution with a mobile phase consisted of acetonitrile–water (50:50, v/v), a flow rate of 1 mL/min, a constant column temperature at 25 °C, and ultraviolet-diode array detection (UV-DAD) at 220 nm. The specificity, selectivity, linearity, precision, and accuracy were tested for the method validation according to the Collaborative International Pesticides Analytical Council (CIPAC) and Directorate General Health and Consumer Protection (SANCO) guidelines and all tested parameters were found within acceptance criteria. The obtained results indicated that the proposed method can be used for routine analysis of the active ingredient malathion in the pesticide formulation “Etiol tecni” following the CIPAC and SANCO rules. The run time of analysis under the stipulated chromatographic conditions was about 2.5 min, meaning that the proposed method requires a small volume (< 1.5 mL) of the organic solvent (acetonitrile) making it cost-effective.
Summary: The modern apple production involves the use of large amounts of pesticides that can be found in processed products such as apple juice. Harmful effects of pesticide residues on humans, especially children, are well known, hence the content of pesticide residues in fruit, vegetables and their juices should be controlled. This study presents an application of a new, relatively simple and reliable analytical method for qualitative and quantitative determination of three organophosphorus and one organonitrogen pesticide residues in apple juices. The analysis utilizes reversed-phase high-performance liquid chromatography (RP-HPLC) followed by UV diode array detection. Prior to HPLC analysis, a solid-phase extraction (SPE) was used for analytes concentration and sample clean-up. Specificity, selectivity, linearity, precision, accuracy and limit of quantification (LOQ) were examined to assess the validity of the developed method. The method had satisfactory values of multiple correlation coefficients for calibration curves (R 2 ≥ 0.95 ). The precision was evaluated for the retention times and peak areas, and the estimated values for relative standard deviations (RSD) were 0.05 % - 0.18 % and 0.09 % - 0.62 %, respectively, which indicated an excellent precision of the proposed method. Under the established conditions, the recovery of analytes was 93.80 % - 119.41 %, with relative standard deviations below 0.56 %. This method was successfully applied for determination of some organophosphorus and organonitrogen pesticide residues in apple juices which were taken from Macedonian markets. The achieved values for LOQs were low enough compared to the MRLs of the investigated pesticides in apple according to the Regulation (EC) No 396/2005. Detectable residues of the examined pesticides were not found in the analyzed samples.
This study presents the development and validation of a new reversed-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous determination of captan, folpet, and metalaxyl residues in table grape samples with ultraviolet–diode array detection (UV–DAD). Successful separation and quantitative determination of analytes was carried out on LiChrospher 60 RP-select B (250 × 4 mm, 5 μm) analytical column. Mixture of acetonitrile–0.1% formic acid in water (65:35, v/v) was used as a mobile phase, with flow rate of 1 mL/min, constant column temperature at 25 °C, and UV detection at 220 nm. The target residues were extracted with acetone by ultrasonication, followed by a cleanup using liquid–liquid extraction (LLE) and solid-phase extraction (SPE). The obtained values for multiple correlation coefficients (R2 > 0.90), relative standard deviation (RSD) of retention times, peak areas and heights (RSD ≤ 2.25%), and recoveries ranging from 90.55% to 105.40%, with RSD of 0.02% to 5.37%, revealed that the developed method has a good linearity, precision, and accuracy for all analytes. Hence, it is suitable for routine determination of investigated fungicides in table grape samples.