Suleman Rasheed

Suleman Rasheed

Auto-generated profile, based on publicly available information

Suleman Rasheed

Department of Biomedical Engineering, The University of Melbourne - Parkville Campus, University of Melbourne, Melbourne, Victoria, 3010, AUSTRALIA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
WMWajid Mumtaz
Wajid Mumtaz
SRSuleman Rasheed
Suleman Rasheed
AIAlina Irfan
Alina Irfan

1 October 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
SRSuleman Rasheed
Suleman Rasheed
JBJames Bennett
James Bennett
PYPeter E Yoo
Peter E Yoo
ABAnthony N Burkitt
Anthony N Burkitt
DGDavid B Grayden
David B Grayden
Objective. An oculomotor brain–computer interface (BCI) records neural activity from brain regions involved in planning eye movements and translates this activity into control commands. While previous successful studies have relied on invasive implants in non-human primates or electrooculography artefacts in human electroencephalogram (EEG) data, this study aimed to demonstrate the feasibility of an oculomotor BCI using a minimally invasive endovascular Stentrode TM device implanted near the supplementary motor area of a patient with amyotrophic lateral sclerosis (ALS). Approach. One participant performed self-paced visually-guided and free-viewing saccade tasks in four directions (left, right, up, down) while endovascular EEG and eye gaze recordings were collected. Visually-guided saccades were cued with visual stimuli, whereas free-viewing saccades were self-directed without explicit cues. Brain signals were pre-processed to remove cardiac artefacts, downsampled, and classified using a Random Forest algorithm. For saccade onset classification (fixation vs saccade), features in time and frequency domains were extracted after xDAWN denoising, while for saccade direction classification, the downsampled time series were classified directly without explicit feature extraction. Main results. The neural responses of visually-guided saccades overlapped with cue-evoked potentials, while free-viewing saccades exhibited saccade-related potentials that began shortly before eye movement, peaked approximately 50 ms after saccade onset, and persisted for around 200 ms. In the frequency domain, these responses appeared as a low-frequency synchronisation below 15 Hz. Saccade onset classification was robust, achieving mean area under the receiver operating characteristic curve (AUC) scores of 0.88 within sessions and 0.86 across sessions. Saccade direction decoding yielded within-session AUC scores of 0.67 for four-class decoding and up to 0.75 for the best performing binary comparisons (left vs up and left vs down). Significance. This proof-of-concept study demonstrates the feasibility of an endovascular oculomotor BCI in a patient with ALS, establishing a foundation for future oculomotor BCI studies in human subjects.