Marcos Norberto Giordano

Marcos Norberto Giordano

Auto-generated profile, based on publicly available information

Marcos Norberto Giordano

Department of Orthopedic Surgery, Galeão Air Force Hospital (Hospital de Força Aérea do Galeão), Rio de Janeiro, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
FGFelipe F. Gonzalez
Felipe F. Gonzalez
RFRaphael Fonseca
Raphael Fonseca
GLGustavo Leporace
Gustavo Leporace
RPRafael Pitta
Rafael Pitta
MGMarcos N. Giordano
Marcos N. Giordano
LMLeonardo Metsavaht
Leonardo Metsavaht
The movement of the arm relative to the trunk results from 3-dimensional (3D) coordinated movements of the glenohumeral (GH) and scapulothoracic (ST) joints and dictates the scapulohumeral rhythm (SHR). Alterations in SHR increase joint overload and may lead to low functional scores, pain, and failures in patients undergoing reverse total shoulder arthroplasty (RSA). The goal of this systematic review and meta-analysis was to examine 3D SHR kinematics after RSA and compare it to that of asymptomatic shoulders. A systematic review and meta-analysis of articles in English were performed using PubMed, Embase, Cochrane Library, and SciELO. Additional studies were identified by searching bibliographies. Search terms included “Reverse shoulder arthroplasty”, “3D”, and “scapula”. It was selected cross-sectional studies that reported SHR with 3D motion analysis systems in patients who underwent RSA and asymptomatic controls. Two authors independently performed the extraction of articles using predefined data fields, including study quality indicators. Data from four studies were included in quantitative analysis, totaling 48 shoulders with RSA and 63 asymptomatic shoulders. Pooled analyses were based on random-effects model (DerSimonian-Laird). A statistically smaller SHR ratio was observed in the RSA group than that in the control group (P < .00001), meaning a greater contribution of ST joint in relation to GH joint for arm elevation. The standardized mean difference was −1.16 (95% confidence interval: −1.64, −0.67). A sensitivity analysis with three more studies that had imputed data on control group did not change the direction of the effect. The standardized mean difference on sensitivity analysis was −0.60 (P = .03; 95% confidence interval: −1.13, −0.06). It was detected as “not important heterogeneity” within the comparison (I2: 22%). Chi-square was not statistically significant (Chi2: 3.85), and I2 was 22%. Tau2 was not zero (Tau2: 0.05). Sensitivity analysis showed an I2 of 74%, which might represent substantial heterogeneity, Chi-square was not statistically significant (Chi2: 23.01), and Tau2 was not zero (Tau2: 0.37). This study found that RSA shoulders have an increased contribution of ST joint during arm elevation, compared with asymptomatic shoulders. More movement in ST joint in proportion to GH joint increases GH joint contact forces, which could lead to component loosening or other complications. Further studies should address the clinical implications of this kinematic finding.

31 March 2021 in Revista Brasileira de Ortopedia
Verified
Journal Article
Open access
PDF file
AFANDERSON FREITAS
ANDERSON FREITAS
LSLandwehrle de Lucena da Silva
Landwehrle de Lucena da Silva
RCRenilton Rodrigues Costa
Renilton Rodrigues Costa
LRLucas Sacramento Ramos
Lucas Sacramento Ramos
MGMarcos Norberto Giordano
Marcos Norberto Giordano
HGHenrique Mansur Gonçalves
Henrique Mansur Gonçalves
Resumo: Objetivo Identificar a energia necessária para ocorrência de fratura do fêmur proximal em osso sintético após retirada de três modelos de implantes: parafusos canulados, parafuso dinâmico do quadril (dynamic hip screw-DHS) e haste femoral proximal (proximal femoral nail-PFN). Métodos Foram utilizados 25 modelos de ossos sintéticos da extremidade proximal do fêmur: 10 unidades de grupo controle (GC), 5 unidades após colocação e retirada de 3 parafusos canulados colocados em configuração de triângulo invertido (GPC), 5 unidades após colocação e retirada do parafuso de compressão dinâmico (GDHS), e 5 unidades após colocação e retirada da haste de fêmur proximal (GPFN). Uma análise biomecânica foi realizada em todas as amostras simulando uma queda sobre o grande trocânter utilizando uma máquina servo-hidráulica com o objetivo de verificar a energia (em Joules [J]) necessária até a ocorrência de fratura nos diferentes grupos. Resultados Todos os grupos apresentaram fratura basocervical. Os grupos GC, GPC, GDHS e GPFN apresentaram, respectivamente, valores de 7.1J, 6.6J, 6J e 6.7J de energia até ocorrência da fratura. Não houve diferença estatisticamente significativa (intervalo de confiança de 95%) na energia entre os grupos de estudo (p = 0,34). Conclusão Não houve diferença estatisticamente significativa nos valores de energia necessária para ocorrência de fratura da extremidade proximal do fêmur após a retirada de três tipos de implantes utilizando modelos sintéticos simulando queda sobre o grande trocânter.