3 July 2023 in Journal of Lightwave Technology
We propose a hybrid integrated self-injection locked (SIL) narrow linewidth laser with adjustable feedback intensity. An adjustable Sagnac loop reflector (ASLR) coupled to a high- Q micro-ring resonator is introduced to adjust and optimize the optical feedback intensity of the SIL laser. The experimental results show that the linewidth and tuning performance of the SIL laser are closely related to the optical feedback intensity. After optimizing the reflectivity of ASLR, more excellent frequency noise suppression capability and larger locking range can be obtained compared with the conventional SIL lasers with fixed feedback intensity. The intrinsic linewidth is reduced to 60 Hz, and the locking range without phase compensation is extended to 6.3 GHz. This work has important application value in the field of coherent detection and precision metrology.
7 January 2009 in Applied Optics
A dissolved oxygen sensor made of plastic optical fiber as the substrate and dichlorotris (1, 10-phenanthroline) ruthenium as a fluorescence indicator is studied. Oxygen quenching characteristics of both intensity and phase were measured; the obtained characteristics showed deviation from the linear relation described by the Stern–Volmer equation. A two-layer model is proposed to explain the deviation, and main parameters can be deduced with the model.
22 April 2022 in Applied Optics
The delayed self-heterodyne and self-homodyne (DSH) method is widely used for measuring the line shapes of high coherent lasers. This method results in an autocorrelation of a laser line under the condition of a delay that is much larger than its coherent time. In practice, the delay is often not so long, especially for very narrow linewidth lasers, resulting in errors in rebuilding the laser’s line shape from the DSH line. Many papers were devoted to the topic, but most of them are based on the formula for white noise. Analytical formulas of phase variance for noises are presented in this paper; the DSH line shapes for different noise types and different delay lengths are simulated based on the formulas. Some experimental data of the DSH line, combined with the power spectral density of frequency noise, are processed, showing good agreement with the theoretical analysis. It is indicated that the DSH line shape shows complicated behaviors varied with the delay, with noise types, and with the measurement duration. Such effects are to be compensated for in retrieving the laser’s linewidth from the DSH data.
18 January 2013 in Applied Optics
A coupled-mode equation (CME) of twisted birefringent fiber is presented in this paper, which uses the degenerate polarization modes of single-mode fibers as eigenmodes in a unified coordinate. The inconsistency between the coordinate and the rotating principal axis, existing in the previous CME, is solved by conversion to the lab coordinate. The CME gives self-consistent results for fibers with high birefringence or low birefringence and for single-mode fibers as well. Analyses and simulations show the CME gives characteristics of twisted birefringent fiber coincident with the property of polarization-maintaining fibers.
15 October 2018 in IEEE Sensors Journal
Performances of centroid analysis (CA) used for extracting Brillouin frequency shift (BFS) from noisy signals are studied in this paper. The variance of extracted BFS, i.e. the minimum detectable BFS, is deduced as a function of signal-to-noise ratio (SNR), frequency step, Brillouin linewidth and the data window used in the analysis. It is found theoretically that both of the averaged BFS and its variance are susceptible to the deviation of data window center from real Brillouin central frequency, termed data window deviation (DWD). The theoretically analyzed results are verified by experiments and simulation, showing good agreement with each other. Since DWD occurs often for noisy signals, an iterative centroid analysis (ICA) is proposed and demonstrated to reduce this impact and improve the accuracy of centroid analysis. Compared with curve fitting methods (CFM) the centroid analysis has attractive features, such as extremely shorter time of processing. The centroid analysis is especially suitable for extracting BFS from complicated spectra observed often in sensors paved in fields, for which the usual CFM may yield wrong results.