3 August 2022 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
1 January 2020 in Quantitative Imaging in Medicine and Surgery
Background: This work proposed a joint L1 and total variation (TV) regularized reconstruction method for X-ray fluorescence tomography (XFT), and investigated the performance of this method in quantitative imaging of gold nanoparticles (GNPs). Methods: We developed a dual-modality XFT/CT imaging system which consisted of a benchtop X-ray source, a translation/rotation stage, a silicon drift detector for X-ray fluorescence (XRF) detection, and a flat panel detector for transmission X-ray detection. A pencil-beam collimator was 3D printed with steel and employed in sample excitation. The sensitivity of the XFT imaging system was determined by imaging water phantoms with multiple inserts containing GNP solutions of various concentrations (0.02–0.16 wt.%). A joint L1 and total variation (TV) regularized algorithm was developed for XFT reconstruction, where the L1 regularization was used to reduce image artifacts and the TV regularization was used to preserve the shape of targets. Nonlinear conjugate gradient (NCG) descent algorithm with backtracking line search was adopted to solve the reconstruction problem. We compared the L1 + TV regularization method with filtered back projection (FBP), maximum likelihood expectation maximization (ML-EM), L1 regularization, and TV regularization methods. Contrast-to-noise ratio (CNR), Dice similarity coefficient (DSC) and localization error (LE) metrics were used to compare the performance of different methods. The CT and XFT imaging doses were also measured using EBT2 radiochromic films. Results: The 3D printed pencil-beam collimator shaped an excitation beam with a 2 mm full width at half maximum at the imaging isocenter. Based on the phantom imaging experiments, the joint L1 and TV regularization method performed better than FBP, ML-EM, L1 regularization and TV regularization methods, with higher localization accuracy (offset 0.99) between the reconstructed and true GNP concentration. The estimated XFT imaging dose is about 41.22 cGy under current setting. Conclusions: The joint L1 + TV regularized reconstruction algorithm performed better in noise suppression and shape preservation. Using the L1 + TV regularized reconstruction, the XFT system is able to localize GNP targets with submillimeter accuracy and quantify GNP distribution at a concentration of 0.02 wt.% or lower.
16 April 2016 in Journal of Radiation Oncology
Objective Radionuclides are commonly used as internal radiation sources for diagnostic imaging or external radiation sources for treatment purposes. As most radionuclides have a higher energy level than imaging X-ray tubes, radionuclides are rarely used as a transmission-based external imaging source. In this study, we designed and simulated an imaging model by using 192Ir as an external imaging source to investigate the feasibility of this new imaging method. The goal of this study is to build a portable and flexible dual-function platform that can conduct both imaging and radiation treatment by using a single radiation source. Methods This study uses the Monte Carlo (MC) method to simulate breast fan beam computed tomography (FBCT) and cone beam computed tomography (CBCT) by using 192Ir as an external source. The whole breast phantom is built from a real patient’s chest CT data. We designed an imaging model and embedded it into the Electron Gamma Shower (EGS) simulation environment. CBCT and FBCT data were obtained through EGS simulations. Different image processing techniques were applied to the data. Results A total of 47 images were reconstructed. Among these images, 16 images have high-density areas (lesions). Comparing with the original CT slices, the lesion volume from both FBCT and CBCT data sets can be identified. CBCT-reconstructed images contain more blurring and noise than FBCT images because of the scattering effects. Conclusion The 192Ir radionuclide can be used as a possible external radiation source for breast imaging. Considering 192Ir’s therapeutic application and outcomes from its imaging simulation by this study, a new imaging/therapy platform can be potentially created.