Dongsheng Zhao

Dongsheng Zhao

Auto-generated profile, based on publicly available information

Dongsheng Zhao

VSL, Dutch Metrology Institute, Thijsseweg 11, 2629 JA Delft, The Netherlands

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2014 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DHdavid humphreys
david humphreys
PHPeter Harris
Peter Harris
MRManuel Rodriguez-Higuero
Manuel Rodriguez-Higuero
FMFaisal Ali Mubarak
Faisal Ali Mubarak
DZDongsheng Zhao
Dongsheng Zhao
KOKari Ojasalo
Kari Ojasalo
We investigate a principal component analysis approach for compressing the covariance matrices derived from real-time and sampling oscilloscope measurements. The objective of reducing the data storage requirements to scale proportional to the trace length n rather than n 2 is achieved, making the approach practical for representing results and uncertainties in either the time or frequency domain. Simulation results indicate that the covariance matrices can be represented in a compact form with negligible error. Mathematical manipulation of the compressed matrix can be achieved without the need to reconstruct the full covariance matrix. We have demonstrated compression of data sets containing up to 10000 complex frequency components.

21 November 2016 in Metrologia
Verified
Journal Article
Closed access
PDF file
DZD Zhao
D Zhao
GRGerrit Rietveld
Gerrit Rietveld
JBJ-P Braun
J-P Braun
FOF Overney
F Overney
TLT Lippert
T Lippert
ACA Christensen
A Christensen
In order to perform traceable measurements of the electrical parameters of solid-state lighting (SSL) products, it is necessary to technically adequately define the measurement procedures and to identify the relevant uncertainty sources. The present published written standard for SSL products specifies test conditions, but it lacks an explanation of how adequate these test conditions are. More specifically, both an identification of uncertainty sources and a quantitative uncertainty analysis are absent. This paper fills the related gap in the present written standard. New uncertainty sources with respect to conventional lighting sources are determined and their effects are quantified. It shows that for power measurements, the main uncertainty sources are temperature deviation, power supply voltage distortion, and instability of the SSL product. For current RMS measurements, the influence of bandwidth, shunt resistor, power supply source impedance and ac frequency flatness are significant as well. The measurement uncertainty depends not only on the test equipment but is also a function of the characteristics of the device under test (DUT), for example, current harmonics spectrum and input impedance. Therefore, an online calculation tool is provided to help non-electrical experts. Following our procedures, unrealistic uncertainty estimations, unnecessary procedures and expensive equipment can be prevented.