Álvaro Tormos

Álvaro Tormos

Auto-generated profile, based on publicly available information

Álvaro Tormos

ITACA Institute, Universitat Politcnica de Valncia, Valencia, Spain

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2023 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
LPLucía Pancorbo
Lucía Pancorbo
SRSamuel Ruipérez-Campillo
Samuel Ruipérez-Campillo
ÁTÁlvaro Tormos
Álvaro Tormos
AGAntonio Guill
Antonio Guill
RARaquel Cervigon Abad
Raquel Cervigon Abad
FCFrancisco Castells
Francisco Castells
High-density multielectrode catheters are becoming increasingly popular in cardiac electrophysiology for advanced characterisation of the cardiac tissue, due to their potential to identify impaired sites. These are often characterised by abnormal electrical conduction, which may cause locally disorganised propagation wavefronts. To quantify it, a novel heterogeneity parameter based on vector field analysis is proposed, utilising finite differences to measure direction changes between adjacent cliques. The proposed Vector Field Heterogeneity metric has been evaluated on a set of simulations with controlled levels of organisation in vector maps, and a variety of grid sizes. Furthermore, it has been tested on animal experimental models of isolated Langendorff-perfused rabbit hearts. The proposed parameter exhibited superior capturing ability of heterogeneous propagation wavefronts compared to the classical Spatial Inhomogeneity Index, and simulations proved that the metric effectively captures gradual increments in disorganisation in propagation patterns. Notably, it yielded robust and consistent outcomes for $\mathbf {4\times 4}$ grid sizes, underscoring its suitability for the latest generation of orientation-independent cardiac catheters.

4 August 2014 in Revista Espanola de Cardiologia
Verified
Journal Article
Closed access
AGAntonio Guill
Antonio Guill
ÁTÁlvaro Tormos
Álvaro Tormos
JMJosé Millet
José Millet
EREduardo J. Roses
Eduardo J. Roses
ACAntonio Cebrián
Antonio Cebrián
FCFrancisco J Chorro
Francisco J Chorro

1 January 2009
Verified
Book Chapter
Closed access
PDF file
AIAntonio Guill Ibáñez
Antonio Guill Ibáñez
ERE. Roses
E. Roses
XIX. Ibáñez-Català
X. Ibáñez-Català
ATA. Tormos
A. Tormos
MGM. S. Guillem
M. S. Guillem
JMJosé Millet
José Millet

1 October 2021 in European Heart Journal
Verified
Journal Article
Closed access
PDF file
CCC J Calvo
C J Calvo
MZManuel Zarzoso
Manuel Zarzoso
AGA Guill
A Guill
ATA Tormos
A Tormos
LSLuis Such
Luis Such
FCF J Chorro-Gasco
F J Chorro-Gasco
Introduction: Optical mapping (OM) is the primary method for imaging electrophysiologically relevant parameters from the outer surface of Langendorff-perfused hearts. However, current panoramic OM systems are financially challenging, require multiple sensors to map wide areas of the surface with overlapping regions and missing areas of interest due to the intrinsic shape of the heart. We proposed different panoramic configurations to dynamically characterize atrial and ventricular function during arrhythmia and, in presence of a coronary occlusion. Methods: We devised both a multi-sensor and a single sensor system integrated with the perfusion circuit comprising sensor elements, a control system for led illumination, electrical stimulation and sensing of physiological variables. Two configurations were tested: A multi-sensor panoramic approach including different camera views and, a precision near-ellipsoidal curved mirror (highly concentrated reflectance in the range 380nm-800nm), with exponential profile and diameter to harbor small to large hearts was used. Twelve-rabbits and two pig hearts were included in the study. OM was performed using di-4 ANDBQPQ near-infrared dye and 5–10uM blebbistatine. Initial camera calibration was done using a fishnet-like pattern and nylon landmarks. We characterized signal-tonoise ratios (SNR) of reconstructed action potentials (AP) and obtained parametric maps of the activation process. A custom-built computational pipeline for accurate motion compensation and AP reconstructions was used. Hearts were stimulated until ventricular fibrillation (VF) was induced with and without presence of a coronary occlusion in the LADartery (LADCO). Results: High SNRs spatial maps were obtained after AP reconstruction (42.24±4.23dB,stimulated; 23.31±5.24dB,VF) in the most restrictive set-up, the single-sensor near-ellipsoidal configuration. Quantified activation and repolarization dynamic restitution properties were assigned to anatomically labelled scale-invariant areas in the atrium and ventricles during the induction process. Atrial and ventricular restitution dynamics could be reconstructed and analyzed simultaneously. Slower conduction (CT) and higher dispersion in repolarization (DoR) was observed after LADCO in LV (CT: 13.4±5.31ms-vs-22.42±6.82ms,DoR:23.24±4.23ms-vs-38.03±9.17ms,p<0.05). During VF, more heterogeneous activation patterns, enhanced left-to-right VV spectral gradient profiles, and spatially constraint shorter-lived filaments, partially explained the disturbances observed during LADCO. Results obtained with a direct multiple sensor configuration allowed for complete tracking of dominant sources, yet presenting overlapped information. Conclusion: Hereby results comparing two low-cost configurations for panoramic imaging are presented and validated for the study of cardiac propagation throughout the whole epicardial surface for the study of arrhythmia, drug interventions and cardiovascular disease. Funding Acknowledgement: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): CIBERcv