1 January 2020 in Journal of Applied Oral Science
The site of the sinus tract depends on the rate of resistance against abscess exudate drainage, bone morphology, and distance from the root apex to the outer cortical bone. To assess apical bone thickness in buccal and palatal/lingual aspects of maxillary and mandibular teeth, using a high-resolution cone-beam computed tomography (CBCT) system. In total, 422 CBCT examinations were included in the study, resulting in a sample of 1400 teeth. The scans were acquired by PreXion 3D, with a high-resolution protocol. The bone thickness was taken as the distance between the center of the apical foramen and the buccal and lingual/palatal cortical bone. The quantitative variables were expressed as mean values±standard deviation. The independent samples were analyzed using the t-test or the Mann-Whitney test (p<0.05). The lowest mean value of bone thickness was observed in the buccal cortical bone of the upper canines (1.49 mm±0.86) and in the upper central incisors (1.59 mm±0.67). In premolar teeth, the lowest values were found in the buccal cortical bone of upper first premolars (1.13 mm±0.68). In the posterior teeth, the lowest values were found in the buccal cortical bone of upper first molars (1.98 mm±1.33). In the lower second molar region, the buccal cortical bone (8.36 mm±1.84) was thicker than the lingual cortical bone (2.95 mm±1.16) (p<0.05). The lowest mean values of bone thickness are in the buccal cortical bone of the maxillary teeth. In the mandible, bone thickness is thinner in the buccal bone around the anterior and premolar teeth, and in the lingual aspect of mandibular molars. All these anatomic characteristics could make the occurrence of the sinus tract more susceptible in these specific regions of the maxillary and mandibular alveolar bone.
1 September 2021 in Brazilian Dental Journal
The aim of this review is to discuss the digital planning and the use of guided technology in Endodontics. The complexity of the root canals anatomy and the challenges in the microorganism’s control represent risk factors for failure after the infected root canal’s treatment. Scientific improvements associated with technological advances have enabled better predictability of therapeutic procedures results. The development of efficient and modern devices provided safer root canal treatments, with shorter clinical visits and greater patient comfort. Digital endodontics incorporated different tools and developed its own, advancing even further in resolving complex cases. The faithful copy of the internal anatomy provided by the advancement of CBCT devices and software’s, associated with the digital resources of 3D planning and printing, enabled the advent of guided endodontics. This technique is used at different stages of endodontic treatment, with specific indications and greater result predictability. Therefore, this study critically reviewed the potential clinical application of this guided access technique, and the operative steps for its safe performance in managing complex endodontic cases. The main indications are accessing calcified root canals, performing endodontic surgeries in difficult access areas, removing fiberglass posts, and accessing teeth with developmental anomalies. In summary, guided endodontics has been a precise strategy, effective, safe, and clinically applicable. This procedure represents incorporating technological resources and digital planning in the Endodontist clinical practice, increasing predictability to complex cases.
1 November 2020 in Brazilian Dental Journal
This study evaluated the dimensions of intraradicular posts using a new cone beam CT (CBCT) software, and verified the potential of blooming artifact reduction. Sixty-three single-rooted human teeth were shaped, obturated, prepared for intracanal post placement and distributed into three groups: G1: anatomically customized prefabricated glass fiber posts; G2: low-fusion alloy posts; G3: gold alloy posts. After post fabrication and luting with RelyX U200®, specimens were sectioned axially at 9 mm from the root apex, and markings were made on the root surfaces (X-, Y- and Z-axes). The dimensions of the original posts (control group) were measured using a digital micrometer. CBCT scans of the teeth were obtained using a PreXion 3D Elite® scanner. Posts were measured on CBCT scans using DICOM files and the e-Vol DX software. A specific filter, Blooming Artefact Reduction (BAR), was developed to analyze intracanal posts. Statistical data were evaluated using the Van de Waerden nonparametric analysis of variance and, after that, normalized data were analyzed using the Tukey test. The level of significance was set at α = 5%. The measures of the anatomical prefabricated, low-fusion alloy and gold alloy intracanal posts obtained using the e-Vol DX CBCT software and a micrometer were not significantly different (p>0.05). The use of the BAR filter of the e-Vol DX software application did not induce any dimensional differences on CBCT scans of intracanal posts when compared with measurements made with a micrometer on original posts. The use of the BAR filter eliminated blooming artifacts.
1 January 2019 in Journal of Applied Oral Science
AAAna Helena Gonçalves de Alencar
Ana Helena Gonçalves de Alencar
+2
Key words: Dental bleaching; Dental pulp; Clinical trial; Tooth bleaching
1 January 2024 in Brazilian Dental Journal
Teaching requires the incorporation of communication skills, and these potentials may affect the outcomes of the learning process. This study evaluated the quality of communication between professors and students during the process of learning Dentistry. A questionnaire was developed and applied to evaluate their perceptions about their communications in an undergraduate Dentistry course. The questionnaire had ten items to analyze professors’ self-perception and ten for students’ perceptions, using a Likert-like scale and a final open question. During its construction, it was sent to five specialists to analyze content validity. The open question gathered suggestions to improve and intensify communications effectively and to identify vulnerabilities. Total scores ranged from 10 to 50, with 10 as the worst perception, and 50, as the best. The scores were calculated by adding all answers and then dividing that sum by the total number of items. Cronbach’s alpha was calculated to evaluate the instrument’s internal consistency. The level of significance was set at 0.05%. The Student t-test was used to determine differences between groups. Professors’ self-perceptions and students' perceptions of the quality of communication of the university teaching staff during the student's learning process had statistically significant differences. Professors classified their ability to communicate when emitting and receiving information as satisfactory. Students, however, did not fully agree with them, particularly on the items about receiving information. The perceptions identified in this study may lead to a new direction in the communicative behavior of professors and students.
1 January 2020 in Brazilian Oral Research
This study evaluated the interference of enamel and coronal dentin thickness and ambient light in pulse oximetry interpretation, using SaO2the human finger as a reference. Forty-two intact human permanent mandibular molars were sectioned mesiodistally in the central portion. Buccal and lingual dentin surfaces were drilled, and 4 mm, 3 mm and 2 mm enamel/dentin thicknesses were interposed between finger and device, after which SaO2 levels were measured by finger pulse oximetry. A reference device was designed to align pulse oximeter light-emitting diode, buccal surface of tooth, little finger, lingual surface of tooth and photodiode. Variables were described as means and standard deviation, and the confidence interval was reported. Repeated measures analysis of variance (ANOVA) was used to compare the groups, followed by Bonferroni correction. Student t test for paired samples was used to determine presence of ambient light (α = 0.05). Mean SaO2 level was lower at 4.0 ± 0.2 mm thickness, regardless of presence or absence of ambient light (92.7% and 89.3%). The other thicknesses yielded values of 95.5% and 94.5% at 3.0 ± 0.2 mm, and 96.4% and 96.0% at 2.0 ± 0.2 mm (p < 0.001). There were significant differences between SaO2 values at 4.0 ± 0.2 mm, 3.0 ± 0.2 mm and 2.0 ± 0.2 mm thicknesses, in the presence of ambient light. Mean SaO2 level in positive control was 96.3%, and mean pulse rate was 69.5 bpm in presence of ambient light; in the absence of light, these values were 96% and 70.5 bpm. Enamel and dentin thickness interfere with SaO2, regardless of presence or absence of ambient light. The lowest SaO2 levels were found for the thickest tooth samples.