Mei-Chen Kuo

Mei-Chen Kuo

Auto-generated profile, based on publicly available information

Mei-Chen Kuo

CBE, Colorado School of Mines, 1500 Illinois St., Golden, Colorado, 80401-1887, UNITED STATES

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2019 in Journal of Polymer Science Part B: Polymer Physics
Verified
Journal Article
Open access
PDF file
ADAshutosh G. Divekar
Ashutosh G. Divekar
MKMei‐Chen Kuo
Mei‐Chen Kuo
APAndrew M. Park
Andrew M. Park
AMAndrew R. Motz
Andrew R. Motz
ZPZachary S. Page‐Belknap
Zachary S. Page‐Belknap
AHAndrew M. Herring
Andrew M. Herring
Three different perfluorinated type polymers as anion exchange membranes for electrochemical applications were studied. They have a sulfonamide linkage to a spacer methylene chain attached to a tri‐methyl ammonium cation, specifically using a three carbon spacer chain (PFAEM_H_C3), and methylated imide polymers with three (PFAEM_CH3_C3) and six carbon spacer chain (PFAEM_CH3_C6). There are significant number of zwitterionic side chains in the PFAEM_H_C3 polymer and very few in the PFAEM_CH3_C3 or the PFAEM_CH3_C6 polymer. They have similar halide conductivity, but the PFAEM_CH3_C6 showed highest OH− conductivity, 122 mS cm−1 at 80 °C and 95% RH. The larger spacer chain polymer, PFAEM_CH3_C6 has a higher water uptake value (λ = 9) compared to PFAEM_CH3_C3(λ = 7) at 60 °C and 95% RH in the Cl− form. Therefore, it has a larger domain spacing of 4.9 nm versus 4.1 nm from small angle X‐ray scattering data. The polymer was characterized by FTIR and DFT was used to fully assign the spectra. © 2019 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2019, 57, 700–712

1 February 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
CKChulOong Kim
ChulOong Kim
IWIvy Wu
Ivy Wu
MKMei-Chen Kuo
Mei-Chen Kuo
DCDominic J. Carmosino
Dominic J. Carmosino
EBEthan W. Bloom
Ethan W. Bloom
AHAndrew M. Herring
Andrew M. Herring
Commercial proton exchange membrane heavy-duty fuel cell vehicles will require a five-fold increase in durability compared to current state-of-the art light-duty fuel cell vehicles. We describe a new composite membrane that incorporates silicotungstic heteroply acid (HPA), α-K8SiW11O40▪13H2O, a radical decomposition catalyst and when acid-exchanged can potentially conduct protons. The HPA was covalently bound to a terpolymer of tetrafluoroethylene, vinylidene fluoride, and sulfonyl fluoride containing monomer (1,1,2,2,3,3,4,4-octafluoro-4-((1,2,2-trifluorovinyl)oxy)butane-1-sulfonyl fluoride) by dehydrofluorination followed by addition of diethyl (4-hydroxyphenyl) phosphonate, giving a perfluorosulfonic acid-vinylidene fluoride-heteropoly acid (PFSA-VDF-HPA). A composite membrane was fabricated using a blend of the PFSA-VDF-HPA and the 800EW 3M perfluoro sulfonic acid polymer. The bottom liner-side of the membrane tended to have a higher proportion of HPA moieties compared to the air-side as gravity caused the higher mass density PFSA-VDF-HPA to settle. The composite membrane was shown to have less swelling, more hydrophobic properties, and higher crystallinity than the pure PFSA membrane. The proton conductivity of the membrane was 0.130 ± 0.03 S cm−1 at 80 °C and 95% RH. Impressively, when the membrane with HPA-rich side was facing the anode, the membrane survived more than 800 h under accelerated stress test conditions of open-circuit voltage, 90 °C and 30% RH.

23 February 2024 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
CKChulOong Kim
ChulOong Kim
MSMarco J. Salgado
Marco J. Salgado
JHJordan L. Hawks
Jordan L. Hawks
JCJack W. Creel
Jack W. Creel
KDKevin C. Dunn
Kevin C. Dunn
AHAndrew M. Herring
Andrew M. Herring
An anion exchange membrane water electrolyzer (AEMWE) was studied with three electrocatalysts (Co3O4, Mn2O3, MnO2) for the oxygen evolution reactions at 50 °C in 1 M K2CO3(aq). We employ an optimized robust high performance polymer based on a polyethylene mid-block copolymer, poly(vinylbenzyl-N‑methylpiperidinium carbonate)‑b‑polyethylene‑b‑poly(vinylbenzyl-N‑methylpiperidinium carbonate) as the AEM and the anode ionomer. The cathode utilized a high loading of Pt/C, 1 mg cm−2, to minimize contributions to the kinetics. We tested three catalyst loadings (0.5, 2.5, and 4.5 mg cm−2) with a fixed ionomer loading of 0.5 mg cm−2 to assess ionomer-catalyst interactions. The best-performing catalyst loadings were investigated in a 100 h durability test at 750 mA cm−2. The 2.5 mg cm−2 MnO2 catalyst displayed superior performance, with 2.40 ± 0.02 V at 1 A cm−2. In the 100 h durability test, the Mn2O3 catalyst showed a degradation rate of +269 ± 15 μV h−1, whereas Co3O4 and MnO2 showed −800 ± 157 μV h−1, −114 ± 15 μV h−1, respectively with no membrane thinning indicating a gradual improvement. The MnO2 electrode was further investigated in a 500 h test was conducted, revealing a voltage change rate of −21 μV h−1 for 24–375 h. Pre and post-test FTIR mapping revealed evolution of micrometer-sized morphology corresponding to templating by the Ni-foam electrode.

14 September 2015 in ECS Transactions
Verified
Journal Article
Closed access
PDF file
AMAndrew R Motz
Andrew R Motz
JHJames L Horan
James L Horan
MKMei-Chen Kuo
Mei-Chen Kuo
AHAndrew M Herring
Andrew M Herring
High temperature, low humidity fuel cell operation is one method of increasing the potential of commercialization of fuel cell vehicles. In order for performance to be suitable under these conditions, new polymer electrolyte membrane material needs to be synthesized and characterized. One particularly important property is water content. Water is an important aspect of polymer electrolytes, often having strong influence on ion transport and fuel cell performance. A novel material has been made, containing a heteropoly acid covalently bound to a fluoroelastomer. This material was analyzed with DVS to gain insight on water sorption. The data suggested that the water content is similar to Nafion® with respect to humidity, thus some other parameter is likely to cause improved performance under high temperature and low humidity operation.