Peter Baumgärtel

Peter Baumgärtel

Auto-generated profile, based on publicly available information

Peter Baumgärtel

Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Strasse 15, 12489 Berlin, Germany

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
GSG. Schönhense
G. Schönhense
KMK. Medjanik
K. Medjanik
OFO. Fedchenko
O. Fedchenko
AZA. Zymaková
A. Zymaková
SCS. Chernov
S. Chernov
AOA. Oelsner
A. Oelsner
The small time gaps of synchrotron radiation in conventional multi-bunch mode (100–500 MHz) or laser-based sources with high pulse rate (∼80 MHz) are prohibitive for time-of-flight (ToF) based photoelectron spectroscopy. Detectors with time resolution in the 100 ps range yield only 20–100 resolved time slices within the small time gap. Here we present two techniques of implementing efficient ToF recording at sources with high repetition rate. A fast electron-optical beam blanking unit with GHz bandwidth, integrated in a photoelectron momentum microscope, allows electron-optical `pulse-picking' with any desired repetition period. Aberration-free momentum distributions have been recorded at reduced pulse periods of 5 MHz (at MAX II) and 1.25 MHz (at BESSY II). The approach is compared with two alternative solutions: a bandpass pre-filter (here a hemispherical analyzer) or a parasitic four-bunch island-orbit pulse train, coexisting with the multi-bunch pattern on the main orbit. Chopping in the time domain or bandpass pre-selection in the energy domain can both enable efficient ToF spectroscopy and photoelectron momentum microscopy at 100–500 MHz synchrotrons, highly repetitive lasers or cavity-enhanced high-harmonic sources. The high photon flux of a UV-laser (80 MHz, <1 meV bandwidth) facilitates momentum microscopy with an energy resolution of 4.2 meV and an analyzed region-of-interest (ROI) down to <800 nm. In this novel approach to `sub-µm-ARPES' the ROI is defined by a small field aperture in an intermediate Gaussian image, regardless of the size of the photon spot.

15 July 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
SBSergey Borisenko
Sergey Borisenko
AFAlexander Fedorov
Alexander Fedorov
AKAndrii Kuibarov
Andrii Kuibarov
MBMarco Bianchi
Marco Bianchi
VBVolodymyr Bezguba
Volodymyr Bezguba
BBBernd Büchner
Bernd Büchner
Fermi surfaces are essential for predicting, characterizing and controlling the properties of crystalline metals and semiconductors. Angle-resolved photoemission spectroscopy (ARPES) is the only technique directly probing the Fermi surface by measuring the Fermi momenta (kF) from energy- and angular distribution of photoelectrons dislodged by monochromatic light. Existing apparatus is able to determine a number of kF -vectors simultaneously, but direct high-resolution 3D Fermi surface mapping remains problematic. As a result, no such datasets exist, strongly limiting our knowledge about the Fermi surfaces. Here we show that using a simpler instrumentation it is possible to perform 3D-mapping within a very short time interval and with very high resolution. We present the first detailed experimental 3D Fermi surface as well as other experimental results featuring advantages of our technique. In combination with various light sources our methodology and instrumentation offer new opportunities for high-resolution ARPES in the physical and life sciences.

1 October 2000 in Surface Science
Verified
Journal Article
Closed access
MPM Pascal
M Pascal
CLC.L.A Lamont
C.L.A Lamont
PBP Baumgärtel
P Baumgärtel
RTR Terborg
R Terborg
JHJ.T Hoeft
J.T Hoeft
DWD.P Woodruff
D.P Woodruff

1 January 2016 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PBP. Baumgärtel
P. Baumgärtel
MWM. Witt
M. Witt
JBJ. Baensch
J. Baensch
MFM. Fabarius
M. Fabarius
AEA. Erko
A. Erko
HSH. Schirmacher
H. Schirmacher
The RAY-UI project started as a proof-of-concept for an interactive and graphical user interface (UI) for the well-known ray tracing software RAY [1]. In the meantime, it has evolved into a powerful enhanced version of RAY that will serve as the platform for future development and improvement of associated tools. The software as of today supports nearly all sophisticated simulation features of RAY. Furthermore, it delivers very significant usability and work efficiency improvements. Beamline elements can be quickly added or removed in the interactive sequence view. Parameters of any selected element can be accessed directly and in arbitrary order. With a single click, parameter changes can be tested and new simulation results can be obtained. All analysis results can be explored interactively right after ray tracing by means of powerful integrated image viewing and graphing tools. Unlimited image planes can be positioned anywhere in the beamline, and bundles of image planes can be created for moving the plane along the beam to identify the focus position with live updates of the simulated results. In addition to showing the features and workflow of RAY-UI, we will give an overview of the underlying software architecture as well as examples for use and an outlook for future developments.

16 January 2019 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
PBP. Baumgärtel
P. Baumgärtel
PGP. Grundmann
P. Grundmann
TZT. Zeschke
T. Zeschke
AEA. Erko
A. Erko
JVJ. Viefhaus
J. Viefhaus
HSH. Schirmacher
H. Schirmacher
The RAY-UI project started as a proof-of-concept for an interactive and graphical user interface (UI) for the well-known ray tracing software RAY [1]. In the meantime, it has developed into a powerful enhanced version of RAY that also serves as platform for new development, code optimization, and improvement of associated tools [2]. Compared to RAY several extensions and features were implemented: We introduced mono-capillaries and hyperbolic mirrors as new optical elements, and added a “Simple Undulator” as a new light source. Furthermore, we have extended the modelling of Reflection Zone Plates, and added support for SPECTRA [3] files for “Undulator File” light sources. Besides this RAY-UI is now also supporting “smart” parameters which apply to the whole optical system. As an example we show the setup of a plane-grating monochromator beamline in SX-700 mount, where the position of the premirror is calculated automatically according to the c-factor and the grating parameters. As an outlook, we show first results of automatically generated schematic beamline views.

1 January 1999 in Faraday Discussions
Verified
Journal Article
Closed access
PDF file
MPM. Polcik
M. Polcik
Rob LindsayRob Lindsay
Rob Lindsay
PBP. Baumgärtel
P. Baumgärtel
RTR. Terborg
R. Terborg
OSO. Schaff
O. Schaff
DWD. P. Woodruff
D. P. Woodruff
Using N 1s scanned-energy mode photoelectron diffraction (PhD) combined with full multiple scattering simulations the local adsorption site of NO on NiO(100) has been determined. The molecule bonds through the N atom atop a surface layer N atom, while the N–O axis is tilted away from the surface normal by 59(+31/-17)°. The special problems presented by adsorbates on compound surfaces, for the direct inversion of PhD data to provide a first-order site determination, are discussed and some alternative schemes tested.