Fátima Barceló-Rico

Fátima Barceló-Rico

Auto-generated profile, based on publicly available information

Fátima Barceló-Rico

University Institute of Control and Industrial Informatics, Polytechnical University of Valencia, Valencia, Spain

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
FBFátima Barceló-Rico
Fátima Barceló-Rico
JBJorge Bondia
Jorge Bondia
JDJose-Luis Diez
Jose-Luis Diez
PRPaolo Rossetti
Paolo Rossetti
Background: Continuous glucose monitoring (CGM) devices estimate plasma glucose (PG) from measurements in compartments alternative to blood. The accuracy of currently available CGM is yet unsatisfactory and may depend on the implemented calibration algorithms, which do not compensate adequately for the differences of glucose dynamics between the compartments. Here we propose and validate an innovative calibration algorithm for the improvement of CGM performance. Methods: CGM data from GlucoDay ® (A. Menarini, Florence, Italy) and paired reference PG have been obtained from eight subjects without diabetes during eu-, hypo-, and hyperglycemic hyperinsulinemic clamps. A calibration algorithm based on a dynamic global model (GM) of the relationship between PG and CGM in the interstitial space has been obtained. The GM is composed by independent local models (LMs) weighted and added. LMs are defined by a combination of inputs from the CGM and by a validity function, so that each LM represents to a variable extent a different metabolic condition and/or sensor–subject interaction. The inputs best suited for glucose estimation were the sensor current I and glucose estimations Ĝ , at different time instants [ I k , I k -1 , Ĝ k -1 ] ( IIG ). In addition to IIG , other inputs have been used to obtain the GM, achieving different configurations of the calibration algorithm. Results: Even in its simplest configuration considering only IIG , the new calibration algorithm improved the accuracy of the estimations compared with the manufacturer's estimate: mean absolute relative difference (MARD)=10.8±1.5% versus 14.7±5.4%, respectively ( P =0.012, by analysis of variance). When additional exogenous signals were considered, the MARD improved further (7.8±2.6%, P <0.05). Conclusions: The LM technique allows for the identification of intercompartmental glucose dynamics. Inclusion of these dynamics into the calibration algorithm improves the accuracy of PG estimations.

6 December 2011 in Journal of Intelligent Information Systems
Verified
Journal Article
Closed access
PDF file
FBFatima Barcelo-Rico
Fatima Barcelo-Rico
JDJose-Luis Diez
Jose-Luis Diez

27 May 2011 in Knowledge and Information Systems
Verified
Journal Article
Closed access
PDF file
FBFátima Barceló-Rico
Fátima Barceló-Rico
JDJose-Luis Diez
Jose-Luis Diez
JBJorge Bondia
Jorge Bondia