Yihan Guo

Yihan Guo

Auto-generated profile, based on publicly available information

Yihan Guo

Beijing Institute of Ophthalmology , Beijing Tongren Eye Center , Beijing Tongren Hospital , Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory , Beijing , 100730 , China , trhos.com

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2026 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
SLShang Li
Shang Li
YGYihan Guo
Yihan Guo
LTLei Tian
Lei Tian
QWQianru Wu
Qianru Wu
ALAo Li
Ao Li
JYJie Ying
Jie Ying
Purpose: To evaluate long‐term visual quality outcomes, refractive changes, and safety during orthokeratology lens wear in children with myopia over a 3‐year period. Methods: We conducted a retrospective analysis of 130 myopic children aged 8–18 years who wore corneal refractive therapy (CRT) lenses from February 2021 to November 2024. Participants underwent comprehensive ocular examinations, including assessments of visual acuity, refractive error, axial length, corneal thickness, and visual quality parameters at baseline, 1.5 years, and 3 years. Data were analyzed with repeated measures ANOVA, and post hoc comparisons were conducted using the Bonferroni test. Results: Over the three‐year period, there was a slight increase in myopic refractive error and axial length (spherical equivalent: from −1.36 ± 1.17D to −1.69 ± 1.24D; cylindrical power: from −0.70 ± 0.83D to −1.18 ± 0.99D; axial length: from 24.62 ± 0.83 to 25.08 ± 0.85 mm). Overall ocular visual quality improved significantly, with increases in Strehl ratio and modulation transfer function ( p < 0.001), while root mean square (RMS) of total ocular aberrations decreased ( p < 0.001). After 1.5 years of wear, the corneal high‐order aberration (HOA) RMS, corneal spherical aberration (SA) RMS, corneal coma RMS, and corneal tilt RMS all significantly increased ( p < 0.0167), while corneal HOAs in the 5‐mm optical zone were generally greater than those in the 3‐mm optical zone ( p < 0.05). Total intraocular aberration RMS decreased significantly in both zones ( p < 0.001). No significant changes were observed in corneal endothelial cell density, and no cases of microbial keratitis or other vision‐threatening complications occurred. Conclusion: Long‐term CRT lens wear was associated with improved overall and intraocular visual quality, despite increased corneal HOA, with better optical performance in the 3‐mm zone. The observed axial elongation and refractive changes over 3 years were broadly consistent with previously reported orthokeratology outcomes. CRT lenses also demonstrated a favorable safety profile in this cohort.