Rinky Agarwal

Rinky Agarwal

Auto-generated profile, based on publicly available information

Rinky Agarwal

Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2021 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
RARinky Agarwal
Rinky Agarwal
NSNidhi Kalra Singh
Nidhi Kalra Singh
RSRajesh Sinha
Rajesh Sinha
NSNamrata Sharma
Namrata Sharma
Obstetrical forceps-induced Descemet membrane tears (FIDMT) are usually encountered during complicated forceps-assisted deliveries. The condition may lead to significant visual debilitation in young children and is frequently ignored due to its low incidence. Undue stretch on the Descemet’s membrane during the process of forceps-assisted delivery results in their vertical/oblique tear (s), which usually leads to corneal edema in early neonatal life. On its resolution, these residual tears result in visually disabling astigmatism that can lead to dense and recalcitrant amblyopia. Slit-lamp examination, anterior segment optical coherence tomography, specular microscopy, confocal microscopy, and corneal topography and tomography can be employed for its accurate diagnosis. While these can be prevented by improved perinatal care, once diagnosed, they mandate prompt refractive correction and amblyopia therapy to prevent disabling visual deterioration in affected children. In adulthood, medical and surgical management may be planned for symptomatic patients based on coexistent amblyopia as this is the major factor guiding visual prognosis. There is limited comprehensive literature in this regard, and the present review discusses the pathogenesis, clinical features, and recent developments in investigations, management, and outcomes of FIDMT during the last three decades.

29 January 2021 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
NSNamrata Md Sharma
Namrata Md Sharma
CDChandra Mbbs Devi
Chandra Mbbs Devi
RARinky Md Agarwal
Rinky Md Agarwal
RBRahul Kumar Bafna
Rahul Kumar Bafna
AAAmar Agarwal
Amar Agarwal
Four patients with pseudophakic corneal edema were subjected to pre-Descemet endothelial keratoplasty (PDEK) under the direct guidance of microscope-integrated optical coherence tomography (i-OCT). i-OCT facilitated successful type 1 big bubble formation during donor preparation, debridement of the hypertrophic epithelium, planning and placement of surgical wounds, descemetorrhexis with removal of remnant Descemet membrane tags, and identification of correct donor orientation and interface details. It was also possible to discern the stability of intraocular lens, flat iris configuration, adequate stromal hydration, and wound apposition on i-OCT. Preoperative visual acuity was counting fingers (50%), 0.78 logMAR (25%), and 1.48 logMAR (25%), whereas postoperative visual acuity was 0.6 logMAR (50%) and 0.3 logMAR (50%). At 6-months of follow-up, all grafts were clear and well attached, the mean central corneal thickness, graft size, graft thickness, and endothelial cell loss were 557.25 ± 13.45 μm, 7.75 ± 0.20 mm, 25.5 ± 2.64 μm, and 21.6 ± 0.02%, respectively. To conclude, i-OCT helped during various surgical steps of PDEK.

3 December 2019 in BMJ Case Reports
Verified
Journal Article
Closed access
PDF file
RARinky Agarwal
Rinky Agarwal
MGMeghal Gagrani
Meghal Gagrani
AMAsmita Mahajan
Asmita Mahajan
NSNamrata Sharma
Namrata Sharma
Sphingomonas paucimobilis is a low-virulence gram-negative bacillus known to cause various ocular infections such as endophthalmitis, panophthalmitis and keratitis that are usually associated with an underlying risk factor such as peri-partum or postpartum phase, cataract surgery, contact lens use, neurotrophic keratopathy or ocular trauma. We report a case of spontaneously occurring perforated corneal ulcer caused by the organism in a young man managed by penetrating keratoplasty. The course was followed by endophthalmitis with graft infection culminating in phthisis bulbi despite aggressive medical and surgical management. Along with reporting this case, we also present a review of literature on ocular infections caused by the same organism.

12 November 2021 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Closed access
ASAyushi Sinha
Ayushi Sinha
RSRajesh M.D. Sinha
Rajesh M.D. Sinha
VGVinay B. Optom. Gupta
Vinay B. Optom. Gupta
RARinky Agarwal
Rinky Agarwal
PMPrafulla K. Maharana
Prafulla K. Maharana
JTJeewan Singh Titiyal
Jeewan Singh Titiyal
Purpose: To evaluate and compare the visual outcomes of two phakic intraocular lenses in high myopia. Methods: A prospective comparative study was undertaken on 50 eyes of 26 patients {age ≥21 years and divided into two groups (implantable collamer lens [ICL] V4c, n=25 eyes and refractive implantable lens [RIL], n=25 eyes)}. Patients were evaluated for uncorrected distance visual acuity (UCVA), best-corrected distance visual acuity, manifest refractive spherical equivalent (MRSE), contrast sensitivity, intraocular pressure, dilated fundus examination, trabecular-iris angle (TIA), anterior chamber depth, horizontal white-to-white diameter, wavefront aberrometry, and endothelial cell (EC) count. All patients were followed up until 6 months and additionally evaluated for anterior chamber inflammation, cataract, and lens vault. Results: The baseline parameters (UCVA, MRSE, and EC count) and postoperative improvement in UCVA, contrast sensitivity, MRSE, EC loss, safety index, and efficacy index were comparable between both the lenses. The improvement in aberrometric profile was significantly better in the ICL group. The mean postoperative vault was higher in RIL group (434.88±162.48 μm vs. 547.24±159.83 μm, P=0.0173); however, the vault was within normal range in both the groups. The decrease in mean TIA was significantly higher in RIL group (8.58 vs. 13.45 μm, P=0.0073). Conclusion: Acrylic phakic lens can be considered as a suitable alternative to collamer lens for refractive correction of high myopia. The collamer lenses showed slight superiority in some qualitative visual parameters; however, collamer lenses do not present with subjective complaints in the patients.

16 October 2020 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
RARinky Agarwal
Rinky Agarwal
SSSeema Sen
Seema Sen
SKSeema Kashyap
Seema Kashyap
TDTanuj Dada
Tanuj Dada
TNTapas Chandra Nag
Tapas Chandra Nag
RSRamanjit Sihota
Ramanjit Sihota
Purpose: To correlate histopathological changes of trabecular meshwork (TM) with clinical features in primary congenital glaucoma (PCG).Methods: This was a prospective interventional study including 66 eyes of 39 PCG children aged ≤12 months at diagnosis. Corneal clarity, corneal diameter (CD), intraocular pressure (IOP) and cup disc ratio (C:D ratio) were assessed at baseline and at 1-year follow-up. The trabecular meshwork (TM) specimens obtained during primary combined trabeculectomy and trabeculotomy augmented with Mitomycin-C were evaluated on light microscopy to look for eosinophilic membrane (EM), status of trabecular beams and trabecular endothelial cells (TEC), presence of intervening spaces, TM thickness and TEC count which were then correlated with clinical features.Results: At 1-year follow-up, IOP reduced from 27.96±10.2 to 11.88±5.63 mm Hg, p20 mm Hg at presentation (1.86±0.7 mm vs 1.3±0.47 mm, p=0.0356). Eyes with IOP ≤14 mm Hg at final follow-up had lower TEC count than eyes with IOP >14 mm Hg (0.92±0.45 cells/mm2 vs 1.00±0.74 cells/mm2, p=0.0028).Conclusion: A light microscopic analysis of surgical specimens may guide prognosis of PCG. However, larger studies are required to validate these results.

2 March 2022 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
RBRahul Kumar Bafna
Rahul Kumar Bafna
NKNidhi Kalra
Nidhi Kalra
ARAishwarya Rathod
Aishwarya Rathod
MAMohamed Ibrahime Asif
Mohamed Ibrahime Asif
SLSuman Lata
Suman Lata
NSNamrata Sharma
Namrata Sharma
Purpose: To describe a novel modification of tuck-in Tenon's patch graft (TPG) using temporary horizontal mattress sutures and fibrin glue to hitch the graft in the management of corneal perforations. Design: Ambispective interventional case series. Methods: Modified technique of autologous TPG was used to seal corneal perforations measuring 3–5 mm, using horizontal mattress sutures to hitch the graft in a lamellar pocket, followed by application of fibrin glue. The horizontal mattress sutures were removed after the reformation of the anterior chamber. The primary outcome measure was a well formed anterior chamber in the post-operative period and the secondary outcome was epithelization time. Results: The surgery was performed in 22 eyes. The mean age was 43.86 ± 16.02 (26–66) years, with 14 males and eight females. The etiologies of corneal perforation included dry eye (n = 10), neurotrophic keratitis (n = 6), trauma (n = 2), chemical injury (n = 2) and exposure (n = 2). The mean size of the perforation with the thinned-out area was 4.3 mm (range 3–5 mm). The mean duration of epithelialization was 14.31 ± 2.63 days (7–21 days). No intraoperative complications were observed. All eyes had a well-formed anterior chamber in the immediate postoperative period. Postoperatively, two eyes had graft pseudoectasia due to a thick graft and supra tenon haemorrhage each; one eye each had graft thinning with the formation of pseudopterygium and graft melting. Conclusion: Tenon's patch graft, along with the use of temporary horizontal mattress sutures and fibrin glue, is an effective modification of the technique for managing corneal perforations measuring 3–5 mm.