Minje Han

Minje Han

Auto-generated profile, based on publicly available information

Minje Han

Department of Laboratory Medicine, Kangdong Sacred Heart Hospital, Seoul, Korea

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2013 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Open access
PDF file
MHMinje Han
Minje Han
SJSun Hee Jun
Sun Hee Jun
JLJae Ho Lee
Jae Ho Lee
KPKyoung Un Park
Kyoung Un Park
JSJunghan Song
Junghan Song
Sanghoon SongSanghoon Song
Sanghoon Song
Therapeutic drug monitoring (TDM) of anti-tuberculosis (TB) drugs is beneficial for patients responding slowly to treatment and those with multidrug-resistant TB. We used ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) to develop a rapid method for simultaneously measuring the blood concentrations of nine second-line anti-TB drugs: streptomycin, kanamycin, clarithromycin, cycloserine, moxifloxacin, levofloxacin, para-aminosalicylic acid, prothionamide and linezolid. Serum samples were extracted with acidified methanol and neutralized with NaOH. A Waters Acquity HSS T3 column and gradients of ammonium formate and acetonitrile in 0.1% formic acid were used for UPLC separation. Drug concentrations were determined by multiple reaction monitoring in positive ion mode, and assay performance was evaluated. We applied this method to TDM, analysing random serum samples from 85 patients treated with second-line drugs. Sample preparation using acidified methanol extraction followed by neutralization yielded good recovery and ionization efficiency, with chromatographic separation achieved within 3 min per sample. Within-run and between-run precisions were 1.7%–7.5% and 1.7%–12.4%, respectively, at concentrations representing low and high levels for the nine drugs. Lower limits of detection and quantification were 0.025–0.5 and 0.25–5.0 μg/mL, respectively. Linearity was acceptable at five concentrations for each drug. No ion suppression was observed at the retention time for most compounds, except for streptomycin, kanamycin and cycloserine, which were eluted close to the void volume of the column. In a limited pilot study, all quantifiable human samples had values within the validated assay ranges. The performance of our MS/MS detection technique was generally acceptable. The method provided rapid, sensitive and reproducible quantification of nine second-line anti-TB drugs and should facilitate drug monitoring during treatment.

24 December 2012 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MHMinje Han
Minje Han
SSSue Shin
Sue Shin
HPHyewon Park
Hyewon Park
KPKyoung Un Park
Kyoung Un Park
MPMyoung Hee Park
Myoung Hee Park
ESEun Young Song
Eun Young Song
We compared the performances of 3 Multiple Allergen Simultaneous Test (MAST) assays: RIDA Allergy Screen (R-Biopharm, Darmstadt, Germany), MAST Optigen allergy system (Hitachi Chemical Diagnostics, Mountain View, CA), and Polycheck Allergy (Biocheck GmbH, Munster, Germany). Forty sera that tested positive with the RIDA Allergy Screen (20 for food and 20 for inhalant panel) were subjected to MAST Optigen and Polycheck Allergy. For 26 available sera with discrepant results, 62 ImmunoCAP allergen-specific IgE tests (Pharmacia Diagnostics, Uppsala, Sweden) were performed. Percent agreements (kappa value) were 87.6% (0.59) and 91.3% (0.60) between RIDA and MAST; 89.9% (0.55) and 88.3% (0.46) between RIDA and Polycheck; and 86.8% (0.51) and 90.6% (0.61) between MAST and Polycheck. Compared with ImmunoCAP, agreements (kappa value) of inhalant and food panels were 51.7% (0.04) and 33.3% (−0.38) for RIDA; 60.7% (0.27) and 81.8% (0.59) for MAST; and 65.5% (0.26) and 45.5% (0.07) for Polycheck. The agreements between RIDA, MAST, and Polycheck and ImmunoCAP-positivity were 45.7%, 88.2%, and 28.6%, respectively, and the agreements for ImmunoCAP-negativity were 37.0%, 51.9%, and 88.9%. MAST Optigen showed better agreement with ImmunoCAP than other assays in the food panel. Better sensitivity of MAST Optigen and better specificity of Polycheck Allergy were suspected.

22 March 2019 in Journal of Medical Virology
Verified
Journal Article
Closed access
PDF file
JJJae‐Hyun Jeon
Jae‐Hyun Jeon
MHMinje Han
Minje Han
HCHo‐Eun Chang
Ho‐Eun Chang
SPSung‐Soo Park
Sung‐Soo Park
JLJae‐Woong Lee
Jae‐Woong Lee
DHDuck‐Jin Hong
Duck‐Jin Hong

1 January 2014 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
SMSoo Young Moon
Soo Young Moon
MLMin Kyoo Lim
Min Kyoo Lim
SHSusie Hong
Susie Hong
YJYongbum Jeon
Yongbum Jeon
MHMinje Han
Minje Han
JSJunghan Song
Junghan Song
Moon SY, et al. Ann Lab Med. 2014 Jan;34(1):7-14. http://dx.doi.org/10.3343/alm.2014.34.1.7

1 September 2014 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
SSSang Hoon Song
Sang Hoon Song
MHMinje Han
Minje Han
YCYang Seon Choi
Yang Seon Choi
KDKi Soon Dan
Ki Soon Dan
MYMan Gil Yang
Man Gil Yang
JLJaeho Lee
Jaeho Lee
Sang Hoon Song, M.D., Minje Han, M.D., Yang Seon Choi, M.T., Ki Soon Dan, M.S., Man Gil Yang, Ph.D., Junghan Song, M.D., Sung Sup Park, M.D., and Jae Ho Lee, M.D.. Ann Lab Med 2014;34:345-53. https://doi.org/10.3343/alm.2014.34.5.345

22 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Harshad LadeHarshad Lade
Harshad Lade
JKJungmin Kim
Jungmin Kim
YCYousun Chung
Yousun Chung
MHMinje Han
Minje Han
EMEun-Kyung Mo
Eun-Kyung Mo
JKJae-Seok Kim
Jae-Seok Kim
Multiplex nucleic acid amplification assays that simultaneously detect multiple respiratory pathogens in a single nasopharyngeal swab (NPS) specimen are widely used for rapid clinical diagnostics. We evaluated Allplex Respiratory Panel (RP) 1, 2, 3, and the BioFire FilmArray RP assay for detecting respiratory pathogens from NPS specimens. In all, 181 NPS specimens obtained from patients suspected of having respiratory infections during the non-influenza season (August–December 2019) were included. The Allplex RP 1, 2, and 3 detected 154 samples positive for respiratory viruses, whereas the BioFire FilmArray detected viruses in 98 samples. Co-infection with two or more viruses was detected in 41 and 17 NPS specimens by Allplex RP and the BioFire FilmArray RP, respectively. For adenoviruses, Allplex RP 1 detected 31 specimens, compared to 34 by the BioFire FilmArray. In all, 64 NPS specimens were positive for human enterovirus (HEV) and human rhinovirus (HRV) on the Allplex RP, in contrast to 39 HEV/HRV on the BioFire FilmArray. The parainfluenza virus (PIV-1–4) detection rate differed between the two systems. Most discrepant results were observed for NPS specimens with high cycle threshold values obtained by Allplex RP. This study showed concordant performance of the Allplex RP 1, 2, 3, and the BioFire FilmArray RP for the simultaneous detection of multiple respiratory viruses.