A small signal model of a multi-infeed high-voltage direct current (HVdc) transmission system containing a line commutated converter (LCC) and a voltage source converter (VSC) is developed. This model represents the LCC and VSC converters as operational impedances as seen from the converter ac busbar. This permits the converters to be included in the effective short-circuit ratio (ESCR) calculations. The resulting ESCR is referred to in this paper as the “Impedance based Effective Short Circuit Ratio” (IESCR). It is shown that the maximum power transfer limit (referred to as the maximum available power or MAP) of the converters is better predicted by this index compared to the conventional ESCR which ignores the operational impedances of the converters. The question also arises as to how close to this theoretical maximum power transfer limit can the HVdc system operate. Using the small-signal model, it is shown that with commonly used control strategies, the predicted MAP can only be achieved by reducing the controller gains. The results are validated using detailed electromagnetic transients simulation of the multi-infeed VSC-LCC system.
An enhanced line commutated converter (E‐LCC) with embedded fully controlled sub‐modules (SMs) to mitigate commutation failures (CFs) in high voltage direct current (HVDC) system is proposed in this study. The main feature of E‐LCC is that each arm is composed of thyristor valves and series connected fully controlled SMs. The operation modes and voltage–current stresses of embedded SMs in E‐LCC are studied. Then the control strategy, including the pre‐charging scheme of SMs and the coordination control method between the thyristor valves and the SMs, is presented. On the basis of the derived equivalent commutation circuit of E‐LCC‐based HVDC (E‐LCC‐HVDC), the dynamic characteristics of the commutation process are investigated. Then, the impact of E‐LCC‐HVDC on CFs mitigation is theoretically analysed. To validate the proposed E‐LCC‐HVDC, the simulation study is conducted in the electromagnetic transient simulation program PSCAD/EMTDC. The results show that with the embedded SMs, the proposed E‐LCC‐HVDC has the ability to mitigate the CFs and alleviate the power interruption during the AC faults effectively. Furthermore, the theoretical analysis and the presented control method for E‐LCC‐HVDC are also validated.
27 June 2022 in IEEE Transactions on Power Electronics
This article introduces the measurement and analysis of the transient electric field (E-field) derived from the switching operation of the modular multilevel converter (MMC) and the high voltage direct current (HVdc) circuit breaker (CB) in a 200 kV converter station constructed in the Zhoushan Islands, China. It is revealed that the switching transient E-field in the converter station is a quasi-static field. Although the switching E-field pulse is a kind of electromagnetic interference to the secondary electronic circuit of the converter station, it can be used to accurately monitor the action moment of the MMC and the CB. The action moment of the MMC and the CB can be measured with an error of less than 0.005 ms based on the steep pulse front of the switching E-field pulse. This result, which is far more accurate compared to the measurement using the voltage recording system that comes with the converter station. This is of significance to the relay protection of the HVdc transmission system whose fault rapidly develops. Additionally, this method has the advantage of being noninvasive, flexible, and low cost. It has potential application value in the condition monitoring of the MMC and the HVdc CB.
26 April 2023 in IEEE Letters on Electromagnetic Compatibility Practice and Applications
In this letter, a nanosecond-level transient electric field (E-field) sensor based on a monopole electrically small rod antenna is proposed. The working principle and design process of the sensor are analyzed in detail while a finite-element simulation is carried out to verify the response characteristics of the sensor both in time and frequency domains, whose upper cut-off frequency can reach 680 MHz. For the purpose of assessing the actual detection capability of the sensor in HVDC converter stations, the sensor designed in this letter was used to detect the transient radiation E-field in the valve hall during the artificial short-circuit test in the Zhoushan ±200-kV five-terminal flexible dc transmission project. The measurement results of the transient E-field indicates that the sensor is able to respond instantaneously to the radiated E-field generated by the operation of the key power electronic equipment in the valve hall. It demonstrates that the designed sensor can be effectively applied in the scenario of the measurement of transient electromagnetic environment and noninvasive situational awareness technology for high-voltage devices in HVDC systems.
23 May 2023 in IEEE Transactions on Power Delivery
The conventional current or voltage signal-based condition monitoring systems for DC high-voltage equipment have the disadvantages of huge volume, inconvenient operation, and low measurement bandwidth and sampling rate. To overcome these drawbacks, a simplified calculational model of the radiative near-field of the electric field in the circuit breaker valve hall is proposed. This model is based on the analytical model of the finite-length current-carrying linear ideal conductor and reveals the physical mechanism of non-invasive situational awareness based on the transient electric field of electrical devices. Predicated on this model, a reconstruction method for calculating the port transient voltage of the hybrid DC breaker is then established and verified by an artificial short-circuit test in an actual ±200 kV MMC-HVDC system. To the best of the author's knowledge, this is the first pilot short-circuit test in a full-scale MMC-HVDC system involving the hybrid DC breaker. Based on the testing data, the reconstructed and measured voltage show a relatively high degree of consistency both in time and frequency domain. The reconstructed voltage signals based on the radiation near-field not only expose the action time sequence of various electrical equipment with the response time of micro-second order, but also disclose the operation of the key devices and fault types for situational awareness in power system.