1 February 1996 in Journal of Biomechanical Engineering
The effects of hypertension on the stress and strain distributions through the wall thickness were studied in the rat thoracic aorta. Goldblatt hypertension was induced by constricting the left renal artery for 8 weeks. Static pressure-diameter-axial force relations were determined on excised tubular segments. The segments were then sliced into thin ring specimens. Circumferential strain distributions were determined from the cross-sectional shape of the ring specimens observed before and after releasing residual stresses by radial cutting. Stress distributions were calculated using a logarithmic type of strain energy density function. The wall thickness at the systolic blood pressure, Psys, significantly correlated with Psys. The mean stress and strain developed by Psys in the circumferential direction were not significantly different between the hypertensive and control aortas, while those in the axial direction were significantly smaller in the hypertensive aorta than in the control. The opening angles of the stress-free ring specimens correlated well with Psys. The stress concentration factor in the circumferential direction was almost constant and independent of Psys, although the stress distributions were not uniform through the wall thickness. Histological observation showed that the wall thickening caused by hypertension is mainly due to the hypertrophy of the lamellar units of the media, especially in the subintimal layer where the stress increase developed by hypertension is larger than in the other layers. These results indicate that: (a) the aortic wall adapts itself to the mechanical field by changing not only the wall dimensions but also the residual stresses, (b) this adaptation is primarily related to the circumferential stress but not to the axial stress, and (c) the aortic smooth muscle cells seem to change their morphology in response to the mechanical stress.
1 August 1994 in Journal of Biomechanical Engineering
To investigate mechanisms of the mechanical adaptation of soft biological tissues to load, effects of hypertension on the mechanical properties and wall dimensions of thoracic aortas were studied in rats. Goldblatt hypertension was induced in male Wistar rats aged 8 to 9 weeks by constricting their left renal arteries. Two, 4, 8, or 16 weeks after the operation, thoracic aortas were excised and used to determine static pressure-diameter relations and wall dimensions. Wall thickness correlated significantly with the systolic blood pressure before sacrifice, Psys, at each period. The aortic hoop stress became almost constant at all Psys 2 weeks after the operation. On the other hand, the stress calculated for 100 and 200 mmHg correlated negatively with Psys. The incremental elastic modulus of the wall at Psys had a significant correlation with Psys having a positive slope at each period, although the correlation disappeared at 16 weeks after the operation. These results imply that: 1) thickness of the aortic wall increases very rapidly in response to hypertension; 2) wall stress developed by the in-situ blood pressure is kept constant at a normal level irrespective of hypertension; 3) elastic modulus of the wall of the hypertensive rats at the in-situ blood pressure becomes equal to the normal value after relatively long period of time; 4) in response to the alteration of the applied force, dimensional change appears much earlier than the change in the elastic properties.
1 May 1997 in Annals of Biomedical Engineering
1 July 2004 in Journal of Neurosurgery: Spine
Object. The pia mater has received little attention regarding its function in the deformation of the spinal cord under compression. In this study the mechanical properties and function of the spinal pia mater were investigated using three methods. Methods. Spinal cord segments were excised from rabbits. The elastic modulus of the pia mater was measured by performing a tensile test using specimens with the pia mater intact and ones with the pia mater stripped off. The stiffness of the spinal cord was examined by performing a compression test with specimens containing an intact pia mater and ones with a pia mater that was incised at both sides. The cross-sectional area and circumference of the spinal cord were measured on axial views of magnetic resonance images in patients with cervical disc herniations before and after surgery. The pia mater had an elastic modulus of 2300 kPa, which was 460 times higher than that of spinal cord parenchyma. By covering the parenchyma, it tripled the overall elastic modulus of the spinal cord. The pia mater increased the stiffness of the spinal cord and enhanced its shape recovery after removal of the compression. The cross-sectional area of the spinal cord increased after surgery, whereas the circumference of the spinal cord changed little. Conclusions. The pia mater firmly covers the spinal cord and has a high elastic modulus; it therefore provides a constraint on the spinal cord surface. It prevents elongation of the circumference and produces a large strain energy that is responsible for shape restoration following decompression.
10 June 2013 in Nature Communications
Heartbeat is required for normal development of the heart, and perturbation of intracardiac flow leads to morphological defects resembling congenital heart diseases. These observations implicate intracardiac haemodynamics in cardiogenesis, but the signalling cascades connecting physical forces, gene expression and morphogenesis are largely unknown. Here we use a zebrafish model to show that the microRNA, miR-21, is crucial for regulation of heart valve formation. Expression of miR-21 is rapidly switched on and off by blood flow. Vasoconstriction and increasing shear stress induce ectopic expression of miR-21 in the head vasculature and heart. Flow-dependent expression of mir-21 governs valvulogenesis by regulating the expression of the same targets as mouse/human miR-21 (sprouty, pdcd4, ptenb) and induces cell proliferation in the valve-forming endocardium at constrictions in the heart tube where shear stress is highest. We conclude that miR-21 is a central component of a flow-controlled mechanotransduction system in a physicogenetic regulatory loop.
1 September 2002 in Journal of Investigative Dermatology