Hui Hui

Hui Hui

Auto-generated profile, based on publicly available information

Hui Hui

Institute of Automation, Chinese Academy of Sciences

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2023 in Nature Reviews Bioengineering
Verified
Journal Article
Closed access
PDF file
KWKun Wang
Kun Wang
YDYang Du
Yang Du
ZZZeyu Zhang
Zeyu Zhang
KHKunshan He
Kunshan He
ZCZhongquan Cheng
Zhongquan Cheng
JTJie Tian
Jie Tian

1 January 2021 in Theranostics
Verified
Journal Article
Open access
WTWei Tong
Wei Tong
HHHui Hui
Hui Hui
WSWenting Shang
Wenting Shang
YZYingqian Zhang
Yingqian Zhang
FTFeng Tian
Feng Tian
YCYundai Chen
Yundai Chen
Inflammation is a pivotal driver of atherosclerotic plaque progression and rupture and is a target for identifying vulnerable plaques. However, challenges arise with the current in vivo imaging modalities for differentiating vulnerable atherosclerotic plaques from stable plaques due to their low specificity and sensitivity. Herein, we aimed to develop a novel multimodal imaging platform that specifically targets and identifies high-risk plaques in vivo by detecting active myeloperoxidase (MPO), a potential inflammatory marker of vulnerable atherosclerotic plaque.

20 July 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
GSGen Shi
Gen Shi
LYLin Yin
Lin Yin
YAYu An
Yu An
GLGuanghui Li
Guanghui Li
LZLiwen Zhang
Liwen Zhang
JTJie Tian
Jie Tian
Magnetic particle imaging (MPI) is an emerging technique for determining magnetic nanoparticle distributions in biological tissues. Although system-matrix (SM)-based image reconstruction offers higher image quality than the X-space-based approach, the SM calibration measurement is time-consuming. Additionally, the SM should be recalibrated if the tracer’s characteristics or the magnetic field environment change, and repeated SM measurement further increase the required labor and time. Therefore, fast SM calibration is essential for MPI. Existing calibration methods commonly treat each row of the SM as independent of the others, but the rows are inherently related through the coil channel and frequency index. As these two elements can be regarded as additional multimodal information, we leverage the transformer architecture with a self-attention mechanism to encode them. Although the transformer has shown superiority in multimodal fusion learning across several fields, its high complexity may lead to overfitting when labeled data are scarce. Compared with labeled SM (i.e., full size), low-resolution SM data can be easily obtained, and fully using such data may alleviate overfitting. Accordingly, we propose a pseudo-label-based progressive pretraining strategy to leverage unlabeled data. Our method outperforms existing calibration methods on a public real-world OpenMPI dataset and simulation dataset. Moreover, our method improves the resolution of two in-house MPI scanners without requiring full-size SM measurements. Ablation studies confirm the contributions of modeling SM inter-row relations and the proposed pretraining strategy.

10 June 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
SYShang Yaxin
Shang Yaxin
JLJie Liu
Jie Liu
LZLiwen Zhang
Liwen Zhang
XWXiangjun Wu
Xiangjun Wu
PZPeng Zhang
Peng Zhang
JTJie Tian
Jie Tian
Objective. Magnetic particle imaging (MPI) is a new medical, non-destructive, imaging method for visualizing the spatial distribution of superparamagnetic iron oxide nanoparticles. In MPI, spatial resolution is an important indicator of efficiency; traditional techniques for improving the spatial resolution may result in higher costs, lower sensitivity, or reduced contrast. Approach. Therefore, we propose a deep-learning approach to improve the spatial resolution of MPI by fusing a dual-sampling convolutional neural network (FDS-MPI). An end-to-end model is established to generate high-spatial-resolution images from low-spatial-resolution images, avoiding the aforementioned shortcomings. Main results. We evaluate the performance of the proposed FDS-MPI model through simulation and phantom experiments. The results demonstrate that the FDS-MPI model can improve the spatial resolution by a factor of two. Significance. This significant improvement in MPI could facilitate the preclinical application of medical imaging modalities in the future.

1 October 2022 in Visual Computing for Industry, Biomedicine, and Art
Verified
Journal Article
Open access
PDF file
LYLin Yin
Lin Yin
WLWei Li
Wei Li
YDYang Du
Yang Du
KWKun Wang
Kun Wang
ZLZhenyu Liu
Zhenyu Liu
JTJie Tian
Jie Tian
Magnetic particle imaging (MPI) is an emerging molecular imaging technique with high sensitivity and temporal-spatial resolution. Image reconstruction is an important research topic in MPI, which converts an induced voltage signal into the image of superparamagnetic iron oxide particles concentration distribution. MPI reconstruction primarily involves system matrix- and x-space-based methods. In this review, we provide a detailed overview of the research status and future research trends of these two methods. In addition, we review the application of deep learning methods in MPI reconstruction and the current open sources of MPI. Finally, research opinions on MPI reconstruction are presented. We hope this review promotes the use of MPI in clinical applications.

26 January 2021 in Photonics Research
Verified
Journal Article
Closed access
HLHuanhao Li
Huanhao Li
CWChi Man Woo
Chi Man Woo
TZTianting Zhong
Tianting Zhong
ZYZhipeng Yu
Zhipeng Yu
YLYunqi Luo
Yunqi Luo
Puxiang LaiPuxiang Lai
Puxiang Lai
Optical imaging through or inside scattering media, such as multimode fiber and biological tissues, has a significant impact in biomedicine yet is considered challenging due to the strong scattering nature of light. In the past decade, promising progress has been made in the field, largely benefiting from the invention of iterative optical wavefront shaping, with which deep-tissue high-resolution optical focusing and hence imaging becomes possible. Most of the reported iterative algorithms can overcome small perturbations on the noise level but fail to effectively adapt beyond the noise level, e.g., sudden strong perturbations. Reoptimizations are usually needed for significant decorrelation to the medium since these algorithms heavily rely on the optimization performance in the previous iterations. Such ineffectiveness is probably due to the absence of a metric that can gauge the deviation of the instant wavefront from the optimum compensation based on the concurrently measured optical focusing. In this study, a square rule of binary-amplitude modulation, directly relating the measured focusing performance with the error in the optimized wavefront, is theoretically proved and experimentally validated. With this simple rule, it is feasible to quantify how many pixels on the spatial light modulator incorrectly modulate the wavefront for the instant status of the medium or the whole system. As an example of application, we propose a novel algorithm, the dynamic mutation algorithm, which has high adaptability against perturbations by probing how far the optimization has gone toward the theoretically optimal performance. The diminished focus of scattered light can be effectively recovered when perturbations to the medium cause a significant drop in the focusing performance, which no existing algorithms can achieve due to their inherent strong dependence on previous optimizations. With further improvement, the square rule and the new algorithm may boost or inspire many applications, such as high-resolution optical imaging and stimulation, in instable or dynamic scattering environments.