Gene Kitamura

Gene Kitamura

Auto-generated profile, based on publicly available information

Gene Kitamura

Department of Radiology, School of Medicine, University of Pittsburgh

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2019 in Journal of Digital Imaging
Verified
Journal Article
Open access
PDF file
GKGene Kitamura
Gene Kitamura
CCChul Y. Chung
Chul Y. Chung
BMBarry E. Moore
Barry E. Moore
To determine whether we could train convolutional neural network (CNN) models de novo with a small dataset, a total of 596 normal and abnormal ankle cases were collected and processed. Single- and multiview models were created to determine the effect of multiple views. Data augmentation was performed during training. The Inception V3, Resnet, and Xception convolutional neural networks were constructed utilizing the Python programming language with Tensorflow as the framework. Training was performed using single radiographic views. Measured output metrics were accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity, and specificity. Model outputs were evaluated using both one and three radiographic views. Ensembles were created from a combination of CNNs after training. A voting method was implemented to consolidate the output from the three views and model ensemble. For single radiographic views, the ensemble of all 5 models produced the best accuracy at 76%. When all three views for a single case were utilized, the ensemble of all models resulted in the best output metrics with an accuracy of 81%. Despite our small dataset size, by utilizing an ensemble of models and 3 views for each case, we achieved an accuracy of 81%, which was in line with the accuracy of other models using a much higher number of cases with pre-trained models and models which implemented manual feature extraction.

21 June 2020 in European Journal of Radiology
Verified
Journal Article
Closed access
GKGene Kitamura
Gene Kitamura


1 October 2011 in Pediatric Neurology
Verified
Journal Article
Closed access
GKGene Kitamura
Gene Kitamura
DKDaniel Kido
Daniel Kido
NWNathaniel Wycliffe
Nathaniel Wycliffe
JJJ. Paul Jacobson
J. Paul Jacobson
UOUdochukwu Oyoyo
Udochukwu Oyoyo
SAStephen Ashwal
Stephen Ashwal

15 February 2021 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
GKGene Kitamura
Gene Kitamura

26 September 2019 in Arthroscopy, Sports Medicine, and Rehabilitation
Verified
Journal Article
Open access
GKGene Kitamura
Gene Kitamura
MAMarcio Bottene Villa Albers
Marcio Bottene Villa Albers
BLBryson P. Lesniak
Bryson P. Lesniak
SRStephen Joseph Rabuck
Stephen Joseph Rabuck
VMVolker Musahl
Volker Musahl
FFFreddie Fu
Freddie Fu
Purpose: To determine whether using 3‐dimensional (3D)‐printed models in addition to computed tomography (CT) scans to evaluate the primary femoral and tibial tunnels before revision anterior cruciate ligament (ACL) reconstruction leads to better agreement with the surgical approach than CT alone. Methods: Fifteen patients who underwent revision ACL reconstruction were retrospectively identified. The mean age was 24.3 years, and 73% were female. Using only CT images, 3 board‐certified orthopaedists and 5 sports medicine orthopaedic fellows evaluated whether the existing tibial and femoral tunnels were acceptable for the revision surgery. Subsequently, 3D‐printed models were made available in addition to the CT scan, and the same questions were asked. Results: For the attending orthopaedic physicians, adding the 3D‐printed models did not have a significant impact on the tibial or femoral tunnel agreement compared with the surgical approach. With the fellow physicians, however, using the 3D‐printed models with tibial tunnel evaluation led to a higher agreement rate (76%) compared with CT images alone (63%) ( P = .050). Furthermore, with the fellow physicians, there was a higher overall agreement when evaluating both the tibial and femoral tunnels with the addition of 3D‐printed models (74%) compared with CT alone (65%) ( P = .049). Conclusion: Our hypothesis that using 3D‐printed models leads to better agreement with the surgical approach was unsupported based on the response of the board‐certified orthopaedists. Based on the fellow response, it stands to reason that 3D‐printed models may be a useful tool in understanding spatial orientation when planning for revision ACL surgery. Level of Evidence: IV, retrospective case series.