Aqil Azman

Aqil Azman

Auto-generated profile, based on publicly available information

Aqil Azman

Intel Microelectronics, Assembly & Test Technology Development , Kulim, Kedah 09000, Malaysia ; , Nibong Tebal, Penang 14300, Malaysia

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2020 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
AAAqil Azman
Aqil Azman
FNFei Chong Ng
Fei Chong Ng
MZMohd. Hafiz Zawawi
Mohd. Hafiz Zawawi
MAMohamad Aizat Mohamad Aizat Abas
Mohamad Aizat Mohamad Aizat Abas
MZMohd Remy Rozainy Mohd Arif Zainol
Mohd Remy Rozainy Mohd Arif Zainol
WTWei Loon Tam
Wei Loon Tam
Three-dimensional stepped spillway problems are simulated numerically using smoothed particle hydrodynamics (SPH) to visualize the flow of water along the steps and its flow dynamics. In particular, two distinct scaled-down stepped spillway models were studied with each having barrier heights of 10 mm and 25 mm, respectively. The impact of varying the height of the barrier in the design of the stepped spillway is studied in terms of it flow pattern, flow dynamics, aeration efficiency and oxygenation performances. State-of-the-art particle image velocimetry (PIV) experiment was carried out to affirm the validity of SPH findings and it turns out that both the water flow patterns attained in the SPH and PIV are quantitatively comparable. Further quantitative analysis revealed that the flow velocities in both methodologies are in great consensus. Conclusively, this has demonstrated that the capability and reliability of SPH to precisely approximate the water using finite set of particles to model the flow along the stepped spillway. Both stepped spillway configurations show nappe flow regime as the water descends down the steps. Nonetheless, vigorous hydraulic jump phenomena that is associates with the formation of turbulence and vortices is prominently observed in the configuration with larger barrier height. Decisive SPH data obtained concluded that as the barrier height increases from 10 mm to 25 mm, the water flows down the steps faster at lower pressure value and the overall aeration efficiency is improved from 1.1% to 1.2%. The usage of the higher barrier would promote the occurrence of substantial air entrainment during water swirling that will increase the power dissipation in flow. Subsequently, this while lower the power drawn to achieve the desired aeration effect. Ultimately, this study has justified the critical influence of barrier height dimension on the stepped spillway flow behavior and aeration performance.

17 October 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
AAA. Azman
A. Azman
MZM. H. Zawawi
M. H. Zawawi
NHN. H. Hassan
N. H. Hassan
MAMohamad Aizat Mohamad Aizat Abas
Mohamad Aizat Mohamad Aizat Abas
NRNorizham Abdul Razak
Norizham Abdul Razak
MRM.A.Z Mohd Remy Rozainy
M.A.Z Mohd Remy Rozainy
Aeration is an important parameter in water filtration system as it allows the transfer of oxygen to water through turbulence effect which subsequently increases air entrainment in the water. For water treatment application, aeration efficiency is measured to ensure continuous re-oxygenation of the unfiltered water. Aside from aeration, this paper also studies the flow patterns through the use of particle image velocimetry (PIV) setup. Through the use of real scale down physical model laboratory study is performed using PIV to obtain the velocity profile. These velocity profiles will then be used to calculate the aeration efficiency of the water in a cascade aerator system. Based on the findings, the aeration efficiency obtained from the PIV experiment has a maximum value at the lowest point of the cascade aerator system with a value of 0.0139 due to increase in mass flow rate as it moves through the steps with velocity of 0.418 m/s. Therefore, in the design of a cascade aerator system, it is advisable to increase the number of steps since it will increase the aeration efficiency of the system.

1 January 2019
Verified
Conference Paper
Closed access
MNMuhammad Naqib Nashurdin
Muhammad Naqib Nashurdin
AAAizat Abas
Aizat Abas
AAAqil Azman
Aqil Azman
FNF. C. Ng
F. C. Ng
MRM. R. M. Radzi
M. R. M. Radzi
AHA. Hassani
A. Hassani

1 January 2019
Verified
Conference Paper
Closed access
MRM. R. M. Radzi
M. R. M. Radzi
MNMuhammad Naqib Nashrudin
Muhammad Naqib Nashrudin
MZMohd Hafiz Zawawi
Mohd Hafiz Zawawi
AAAizat Abas
Aizat Abas
AAAqil Azman
Aqil Azman
AHA. Hassani
A. Hassani

21 November 2019
Verified
Book Chapter
Closed access
PDF file
NANurhanani A. Aziz
Nurhanani A. Aziz
MZM. H. Zawawi
M. H. Zawawi
NZN. M. Zahari
N. M. Zahari
AAAizat Abas
Aizat Abas
AAAqil Azman
Aqil Azman

1 January 2019
Verified
Conference Paper
Closed access
AAAqil Azman
Aqil Azman
AAAizat Abas
Aizat Abas
MZM. H. Zawawi
M. H. Zawawi
MZMohd. Remy Rozainy M. A. Z.
Mohd. Remy Rozainy M. A. Z.
IAIsmail Abustan
Ismail Abustan