Gleica Dal’ Ongaro Savegnago

Gleica Dal’ Ongaro Savegnago

Auto-generated profile, based on publicly available information

Gleica Dal’ Ongaro Savegnago

Dental Sciences Post-Graduation Program, Federal University of Santa Maria, Santa Maria, Brazil

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2024 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
PDF file
LMLucas Machado Maracci
Lucas Machado Maracci
GSGleica Dal Ongaro Savegnago
Gleica Dal Ongaro Savegnago
RARaquel Pippi Antoniazzi
Raquel Pippi Antoniazzi
MMMariana Marquezan
Mariana Marquezan
TSTatiana Bernardon Silva
Tatiana Bernardon Silva
GLGabriela Salatino Liedke
Gabriela Salatino Liedke
Objectives: This study aimed to verify the accuracy of clinical protocols for the diagnosis of disc displacement (DD) compared with MRI, considering examiners’ calibration. Methods: PubMed, Cochrane (Central), Scopus, Web of Science, LILACS, Embase, Science Direct, Google Scholar, and DANS EASY Archive databases were searched. Two reviewers independently screened and selected the studies. A meta-analysis was conducted using the R Statistical software. Results are shown using sensitivity and specificity, and 95% confidence intervals. Results: Of the 20 studies included in the systematic review, only three were classified as low risk of bias. Seventeen studies were included in the meta-analysis. Compared to MRI, clinical protocols showed overall sensitivity and specificity of 0.75 (0.63-0.83) and 0.73 (0.59-0.84) for DD diagnosis, respectively. For DD with reduction, sensitivity was 0.64 (0.48-0.77) and specificity was 0.72 (0.48-0.87). For DD without reduction, sensitivity was 0.58 (0.39-0.74) and specificity 0.93 (0.83-0.97). Only 8 studies reported examiner calibration when performing clinical and/or MRI evaluation; nevertheless, calibration showed a tendency to improve the diagnosis of DD. Conclusion: The sensitivity and specificity of clinical protocols in the diagnosis of DD are slightly below the recommended values, as well as the studies lack calibration of clinical and MRI examiners. Examiner calibration seems to improve the diagnosis of DD.

1 January 2023 in Imaging Science in Dentistry
Verified
Journal Article
Open access
PDF file
GCGabriela Brum Cardoso
Gabriela Brum Cardoso
GSGleica Dal’ Ongaro Savegnago
Gleica Dal’ Ongaro Savegnago
WHWâneza Dias Borges Hirsch
Wâneza Dias Borges Hirsch
MVMariana Boessio Vizzotto
Mariana Boessio Vizzotto
GLGabriela Salatino Liedke
Gabriela Salatino Liedke
Cardoso GB, et al. Imaging Sci Dent. 2023 Sep;53:e28. https://doi.org/10.5624/isd.20230036

15 May 2025 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
ACAna Carvalho de Christo
Ana Carvalho de Christo
WMWislem Miranda de Mello
Wislem Miranda de Mello
VDVinicius Dutra
Vinicius Dutra
LMLucas Machado Maracci
Lucas Machado Maracci
GSGleica Dal’ Ongaro Savegnago
Gleica Dal’ Ongaro Savegnago
GLGabriela Salatino Liedke
Gabriela Salatino Liedke
Objective: The aim of this study was to evaluate the impact of a 3D-printed model with simulated oral changes on the teaching of radiographic evaluation. Method: A model of an adult patient with several simulated alterations was designed, including impacted teeth, dentigerous cyst, mesiodens, coronal fractures, periodontal resorptions, periapical lesions, and exostoses. The radiographic images obtained were evaluated by postgraduate students using a questionnaire. The data obtained were analysed with descriptive and inferential statistics. Results: The 3D model produced satisfactory images for the simulation of the proposed alterations. The general perception of the participants was positive, but there were significant differences between master's and doctoral students regarding the clinical-radiographic relationship of the simulated changes in general (P = .037) and the radiographic image of impacted canine (P = .032). Conclusions: The 3D model was positively evaluated in most of the simulated alterations, demonstrating its potential as a pedagogical tool. These results reinforce the feasibility of 3D printing for producing models for radiographic assessment, offering image quality and versatility for the development of complex training. Advances in knowledge: This is the first study to develop and evaluate a 3D-printed model with complex anatomical and pathological alterations for preclinical training in Oral and Maxillofacial Radiology.

15 September 2025 in Brazilian Journal of Oral Sciences
Verified
Journal Article
Open access
PDF file
LMLucas Machado Maracci
Lucas Machado Maracci
GBGabriel Fernandes Barbosa
Gabriel Fernandes Barbosa
GSGleica Dal Ongaro Savegnago
Gleica Dal Ongaro Savegnago
WMWislem Miranda de Mello
Wislem Miranda de Mello
MMMariana Marquezan
Mariana Marquezan
GLGabriela Salatino Liedke
Gabriela Salatino Liedke
Aim: This ex vivo study aimed to assess the influence of stainless-steel orthodontic brackets (SSOB) and the acquisition protocol on linear measurements of bone height and width for the planning of dental implants in inter-bracket regions. Methods: Twenty extracted premolar teeth were adapted in artificial sockets on 10 bovine ribs, then adapted into a 3D printed jaw, coated with wax. Cone beam computed tomography (CBCT) scans with and without SSOB were performed using four acquisition protocols, varying the voxel size (280, 200, 125, and 80 μm). Three trained examiners evaluated all 80 CBCT scans, measuring height and width in the center of the simulated edentulous region between the teeth, in the cross-sectional plane. Intra- and inter-examiner reproducibility were assessed using the Intraclass Correlation Coefficient test. Linear measurements were compared using the Bland-Altman method and ANOVA for repeated measures. A significance level of 5% was used. Results: Intra- and inter-examiner reproducibility presented excellent reliability for height measurements, while inter-examiner presented moderate and intra-examiner presented moderate to good reliability. The measurements showed a statistically significant difference between the examiners (p<0.001), regardless of the voxel size or the presence of SSOB. The Bland-Altman showed discrepancies between -0.18 mm and 1.15 mm in the width measurements. Conclusion: The presence of SSOB and the CBCT voxel size do not affect the planning of dental implants in the inter-bracket region.

31 August 2025 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
GSGleica Dal’ Ongaro Savegnago
Gleica Dal’ Ongaro Savegnago
GAGabriela Marzullo de Abreu
Gabriela Marzullo de Abreu
CSCarolina Baumgratz Spiger
Carolina Baumgratz Spiger
LMLucas Machado Maracci
Lucas Machado Maracci
WMWislem Miranda de Mello
Wislem Miranda de Mello
GLGabriela Salatino Liedke
Gabriela Salatino Liedke
Objectives: This study aimed to evaluate the influence of cone-beam computed tomography (CBCT) acquisition protocol, the presence of intraradicular metal post, and examiner experience on the detection of complete root fractures in multi-rooted teeth.Methods: Twenty human molar teeth filled with gutta-percha were placed into artificial alveoli created in bovine ribs. The sample was divided into two groups based on the presence or absence of intraradicular posts in the distal roots. CBCT scans were obtained using four acquisition protocols with varying voxel sizes (0.28, 0.2, 0.125, and 0.80 mm). Following the creation of controlled fractures using a chisel and hammer, CBCT imaging was repeated, resulting in 160 images. Five examiners assessed the images using OnDemand software (KaVo Dental GmbH). Sensitivity, specificity, and accuracy were calculated for each examiner, CBCT protocol, and post-condition. Statistical comparisons were performed using Cochran’s Q test and McNemar test, and a significance level of 5%.Results: In teeth without metallic posts, sensitivity, specificity, and accuracy values exceeded 0.70, 0.70, and 0.80, respectively. However, the presence of metallic posts significantly reduced diagnostic performance, particularly in low-resolution protocols evaluated by less-experienced examiners.Conclusions: CBCT acquisition protocols should be selected based on the presence of metallic posts to optimize root fracture detection in multi-rooted teeth. Examiner experience also plays a critical role in diagnostic accuracy.