15 January 2019 in Optics Express
Current optical coherence tomography (OCT) technology, which is used for imaging the eye’s anterior segment, has been established as a clinical gold standard for the diagnosis of corneal diseases. However, the cellular resolution level information that is critical for many clinical applications is still not available. The major technical challenges toward cellular resolution OCT imaging are the limited ranging depth and depth of focus (DOF). In this work, we present a novel ultrahigh resolution OCT system that achieves an isotropic spatial resolution of <2 µm in tissue. The proposed system could approximately double the ranging depth and extend the DOF using the dual-spectrometer design and the forward-model based digital refocusing method, respectively. We demonstrate that the novel system is capable of visualizing the full thickness of the pig cornea over the ranging depth of 3.5 mm and the border of the corneal endothelial cells 8 times Rayleigh range away from the focal plane. This technology has the potential to realize cellular resolution corneal imaging in vivo.
9 January 2018 in Optics Express
An inherent compromise must be made between transverse resolution and depth of focus (DOF) in spectral domain optical coherence tomography (SD-OCT). Thus far, OCT has not been capable of providing a sufficient DOF to stably acquire cellular-resolution images. We previously reported a novel technique named multiple aperture synthesis (MAS) to extend the DOF in high-resolution OCT [Optica 4, 701 (2017)]. In this technique, the illumination beam is scanned across the objective lens pupil plane by being steered at the pinhole using a custom-made microcylindrical lens. Images captured via multiple distinctive apertures were digitally refocused, which is similar to synthetic aperture radar. In this study, we applied this technique for the first time to image both a homemade microparticle sample and biological tissue. The results demonstrated the feasibility and efficacy of high-resolution biological tissue imaging with a dramatic DOF extension.
17 July 2018 in Applied Optics
We report a dual-focus fiber-optic probe designed to extend depth of focus (DOF) in high-resolution endoscopic optical coherence tomography. We exploited the broad spectral bandwidth of a supercontinuum source and, in the fiber probe, the foci of the 750–1000 nm and 1100–1450 nm inputs were axially chromatically shifted. The interference signals from the two spectral bands were measured with a Si camera-based spectrometer and an InGaAs camera-based spectrometer, respectively. We verified the feasibility of the design using a phantom composed of microparticles and swine small intestine tissue ex vivo. The results showed that a transverse resolution below 5 μm over 300 μm could be maintained, and that the extended DOF was 2 times larger than that of the single focus probe via the use of dual spectral band inputs and a chromatic focal shift.
1 June 2013 in Optical Engineering
A fiber-optic sinusoidal phase-modulating (SPM) interferometer for fringe projection is presented. The system is based on the SPM technique and makes use of the Mach–Zehnder interferometer structure and Young’s double pinhole interference principle to achieve interference fringe projection. A Michelson interferometer, which contains the detection of Fresnel reflection on its fiber end face and interference at one input port of a 3 dB coupler, is utilized to achieve feedback precise control of the fringe phase, which is sensitive to phase drifting produced by the nature of the fiber. The phase diversity for the closed-loop SPM system can be real-time measured with a precision of 3 mrad. External disturbances mainly caused by temperature fluctuations can be reduced to 57 mrad for the fringe map. The experimental results have shown the usefulness of the system.
1 January 2016 in Procedia Engineering
Spectral domain optical coherence tomography (SD-OCT) with dual-balanced detection (DBD) for signal-to-noise ratio (SNR) enhancement is developed. The dual-balanced detection in the SD-OCT system inherently achieves two-fold increase of the interested signal amplitude, minimizes the common background noise and suppresses artifacts by combining two phase-opposed interferometric spectra obtained simultaneously in comparison to unbalanced detection configuration, resulting in a significant SNR increase and dc elimination performance. Two interferometric spectrum were captured using a dual-line CCD through the same spectrometer optics. This new design is of lower cost compared with the dual CCD design. The feasibility and validity of this SD-OCT system with dual-balanced detection are demonstrated by experimental measurement of a 95% reflector.
1 February 2015 in Optics Communications