1 May 2017 in Arabian Journal of Chemistry
In the present study, Response surface methodology (RSM) was employed for the removal of fluoride on Brushite and the process parameters were optimized. Four important process parameters including initial fluoride concentration (40–50mg/L), pH (4–11), temperature (10–40°C) and B dose (0.05–0.15g) were optimized to obtain the best response of fluoride removal using the statistical Box–Behnken design. The experimental data obtained were analyzed by analysis of variance (ANOVA) and fitted to a second-order polynomial equation using multiple regression analysis. Numerical optimization applying desirability function was used to identify the optimum conditions for maximum removal of fluoride. The optimum conditions were found to be initial concentration=49.06mg/L, initial solution pH=5.36, adsorbent dose=0.15g and temperature=31.96°C. A confirmatory experiment was performed to evaluate the accuracy of the optimization procedure and maximum fluoride removal of 88.78% was achieved under the optimized conditions. Several error analysis equations were used to measure the goodness-of-fit. Kinetic studies showed that the adsorption followed a pseudo-second order reaction. The equilibrium data were analyzed using Langmuir, Freundlich, and Sips isotherm models at different temperatures. The Langmuir model was found to be describing the data. The adsorption capacity from the Langmuir isotherm (QL) was found to be 29.212, 35.952 and 36.260mg/g at 298, 303, and 313K respectively
1 March 2012 in Applied Surface Science
1 November 2015 in Journal of Saudi Chemical Society
A study on the adsorption of fluoride onto hydroxyapatite was conducted and the process parameters were optimized using Response Surface Methodology (RSM). Hydroxyapatite has been characterized by using different physicochemical methods. In order to determine the effects of process parameters namely temperature (20–40°C), initial solution pH (4–11), adsorbent dose (0.1–0.3g) and initial fluoride concentration (10–20mgL−1) on fluoride uptake from aqueous solution, a three-level, four-factor, Box–Behnken design has been employed. The second order mathematical model was developed by regression analysis of the experimental data obtained from 29 batch runs. The optimum pH, temperature, adsorbent dose and initial concentration were found by desirability function to be 4.16, 39.02°C, 0.28g and 20mgL−1, respectively. Fluoride removal was 86.34% at the optimum combination of process parameters. Dynamic adsorption data were applied to pseudo-first-order and pseudo-second-order rate equations. The time data fitted well to pseudo second order kinetic model. According to the correlation coefficients, the adsorption of fluoride on the hydroxyapatite was correlated well with the Langmuir and Freundlich models
1 July 2011 in Desalination
1 September 2011 in Desalination
1 October 2012 in Applied Surface Science