Matthew L. Hancock

Matthew L. Hancock

Auto-generated profile, based on publicly available information

Matthew L. Hancock

NASA Kennedy Space Center

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Applied Surface Science
Verified
Journal Article
Closed access
MHMatthew L. Hancock
Matthew L. Hancock
RYRobert A. Yokel
Robert A. Yokel
MBMatthew J. Beck
Matthew J. Beck
JCJulie L. Calahan
Julie L. Calahan
TJTravis W. Jarrells
Travis W. Jarrells
EGEric A. Grulke
Eric A. Grulke

18 June 2020 in Nanotoxicology
Verified
Journal Article
Closed access
RYRobert A. Yokel
Robert A. Yokel
MTMichael T. Tseng
Michael T. Tseng
DBD. Allan Butterfield
D. Allan Butterfield
MHMatthew L. Hancock
Matthew L. Hancock
EGEric A. Grulke
Eric A. Grulke
UGUschi M. Graham
Uschi M. Graham
Prior studies showed nanoparticle clearance was different in C57BL/6 versus BALB/c mice, strains prone to Th1 and Th2 immune responses, respectively. Objective: Assess nanoceria (cerium oxide, CeO2 nanoparticle) uptake time course and organ distribution, cellular and oxidative stress, and bioprocessing as a function of mouse strain. Methods: C57BL/6 and BALB/c female mice were i.p. injected with 10 mg/kg nanoceria or vehicle and terminated 0.5 to 24 h later. Organs were collected for cerium analysis; light and electron microscopy with elemental mapping; and protein carbonyl, IL-1β, and caspase-1 determination. Results: Peripheral organ cerium significantly increased, generally more in C57BL/6 mice. Caspase-1 was significantly elevated in the liver at 6 h, to a greater extent in BALB/c mice, suggesting inflammasome pathway activation. Light microscopy revealed greater liver vacuolation in C57BL/6 mice and a nanoceria-induced decrease in BALB/c but not C57BL/6 mice vacuolation. Nanoceria increased spleen lymphoid white pulp cell density in BALB/c but not C57BL/6 mice. Electron microscopy showed intracellular nanoceria particles bioprocessed to form crystalline cerium phosphate nanoneedles. Ferritin accumulation was greatly increased proximal to the nanoceria, forming core-shell-like structures in C57BL/6 but even distribution in BALB/c mice. Conclusions: BALB/c mice were more responsive to nanoceria-induced effects, e.g. liver caspase-1 activation, reduced liver vacuolation, and increased spleen cell density. Nanoceria uptake, initiation of bioprocessing, and crystalline cerium phosphate nanoneedle formation were rapid. Ferritin greatly increased with a macrophage phenotype-dependent distribution. Further study will be needed to understand the mechanisms underlying the observed differences.

7 February 2019 in Nanotoxicology
Verified
Journal Article
Closed access
RYRobert A. Yokel
Robert A. Yokel
MHMatthew L. Hancock
Matthew L. Hancock
EGEric A. Grulke
Eric A. Grulke
JUJason M. Unrine
Jason M. Unrine
ADAlan K. Dozier
Alan K. Dozier
UGUschi M. Graham
Uschi M. Graham
Ligands that accelerate nanoceria dissolution may greatly affect its fate and effects. This project assessed the carboxylic acid contribution to nanoceria dissolution in aqueous, acidic environments. Nanoceria has commercial and potential therapeutic and energy storage applications. It biotransforms in vivo. Citric acid stabilizes nanoceria during synthesis and in aqueous dispersions. In this study, citrate-stabilized nanoceria dispersions (∼4 nm average primary particle size) were loaded into dialysis cassettes whose membranes passed cerium salts but not nanoceria particles. The cassettes were immersed in iso-osmotic baths containing carboxylic acids at pH 4.5 and 37 °C, or other select agents. Cerium atom material balances were conducted for the cassette and bath by sampling of each chamber and cerium quantitation by ICP-MS. Samples were collected from the cassette for high-resolution transmission electron microscopy observation of nanoceria size. In carboxylic acid solutions, nanoceria dissolution increased bath cerium concentration to >96% of the cerium introduced as nanoceria into the cassette and decreased nanoceria primary particle size in the cassette. In solutions of citric, malic, and lactic acids and the ammonium ion ∼15 nm, ceria agglomerates persisted. In solutions of other carboxylic acids, some select nanoceria agglomerates grew to ∼1 micron. In carboxylic acid solutions, dissolution half-lives were 800–4000 h; in water and horseradish peroxidase they were ≥55,000 h. Extending these findings to in vivo and environmental systems, one expects acidic environments containing carboxylic acids to degrade nanoceria by dissolution; two examples would be phagolysosomes and in the plant rhizosphere.

1 November 2019 in European Journal of Pharmaceutics and Biopharmaceutics
Verified
Journal Article
Closed access
RYRobert A. Yokel
Robert A. Yokel
MHMatthew L. Hancock
Matthew L. Hancock
BCBenjamin Cherian
Benjamin Cherian
ABAlexandra J. Brooks
Alexandra J. Brooks
MEMarsha L. Ensor
Marsha L. Ensor
EGEric A. Grulke
Eric A. Grulke

4 April 2019 in Environmental Science: Nano
Verified
Journal Article
Open access
PDF file
EGEric A. Grulke
Eric A. Grulke
MBMatthew J. Beck
Matthew J. Beck
RYRobert A. Yokel
Robert A. Yokel
JUJason Unrine
Jason Unrine
UGUschi M. Graham
Uschi M. Graham
MHMatthew L. Hancock
Matthew L. Hancock
Nanoparticle dissolution in local milieu can affect its ecotoxicity and therapeutic applications.

1 November 2025 in The Planetary Science Journal
Verified
Journal Article
Open access
PDF file
RARoberto Aguilar Ayala
Roberto Aguilar Ayala
JCJanine E. Captain
Janine E. Captain
JSJames T. Smith
James T. Smith
MHMatthew L. Hancock
Matthew L. Hancock
AJAlexander W. Jarnot
Alexander W. Jarnot
JQJaqueline W. Quinn
Jaqueline W. Quinn
The Volatiles Investigating Polar Exploration Rover (VIPER) is a lunar volatiles detection and measurement mission that will land on Mons Mouton near Nobile crater, close to the Moon’s south pole. One of the analytical instruments embedded within the rover is the Mass Spectrometer observing lunar operations (MSolo) instrument. VIPER’s data will ultimately be used to create lunar water resource maps that may enable a sustained presence on the lunar surface. As VIPER navigates several kilometers of terrain, its onboard analytical instrumentation will characterize the presence of volatiles along the traverse path and identify candidate locations for drilling. Upon selection of a drilling site, the rover will position itself and deploy an auguring, percussive drill down to 1 m depth. Upon extraction, regolith cuttings captured by the auger are deposited on the surface, an activity that will initiate the release of any volatile gases that are subsequently detected and quantified by MSolo. MSolo is designed to identify low-molecular-weight volatiles (between m / z 1 and 100) with unit mass resolution. Volatiles of interest include D / H and O18/O16-bearing species, including possible water contained within the lunar regolith. MSolo is a modified commercial off-the-shelf system, meaning the instrument is based on a commercially available unit that has been ruggedized for space applications.