Radar-based ultra-wideband (UWB) microwave imaging (MI) system has recently attracted considerable attention for detection of breast cancer at early stage. A key component of the system is the sensor (antenna) that is used to radiate and receive the UWB pulses. In this study, a compact-size, UWB, directive, and microstrip-fed planar circular disc monopole antenna (PCDMA) with modified L-shaped ground plane for the radar-based UWB MI system is developed. Analysis and the performance optimization of the proposed antenna are performed by HFSS software. In the development process of the antenna design, some modifications such as adjusting feed point, adding parasitic element, slot, notches are made on the conventional PCDMA to improve the bandwidth, directivity and half-power beamwidth (HPBW) of the antenna. After obtaining the optimum parameters, the proposed antenna is fabricated and then tested by using Vector Network Analyser. Impedance bandwidth of the designed antenna covers the broad frequency range of 3–10 GHz (108%) for Return Loss < –10 dB. The good stability of the directional radiation patterns is obtained in the 3–10 GHz. The direction of the maximum radiation moves from 32° to 54° and HPBW decreases from 56° to 30° through the frequency band. The directivity changes between 6.2 and 9.4 dB in the 3–10 GHz. Results confirm that the proposed antenna is suitable for using in radar-based UWB MI of the breast cancer.
2 November 2016 in Journal of Exposure Science & Environmental Epidemiology
In this study, it is aimed to demonstrate the effects of the feed line position on the operating frequency, return loss and bandwidth of the rectangular patch microstrip antenna. For this purpose, a compact-sized antenna that can operate at 2.4-2.45 GHz frequencies is designed in High Frequency Structure Simulator (HFSS) program. Then, the position of the feedline is changed horizontally and vertically, and its effects are observed. The results obtained after the modificaions are given and discussed. It is stated that the feed line position is a very important parameter that affects the basic characteristics of the antenna.
Detection of the breast cancer tumors at an early stage is very crucial to be successful in the treatment. Microwave measurement systems have gained much attention for this aim over last decades. The main principle of these systems is based on the significant difference in the dielectric properties of the malignant tumor and normal breast tissue in the microwave frequencies. In this paper, firstly several breast cancer detection techniques are mentioned. Then the advantages of the using microwaves in the detection systems are given. After that, some simulation and experimental studies of the radar-based ultra-wideband microwave measurement system are presented to detect tumor. The main purposes of these measurements are comparing the performance of a previously designed planar monopole antenna (PMA) with a dual-ridge horn (DRH) antenna and demonstrating a simple microwave breast cancer detection system. In the system, a planar breast phantom which is consisted of low dielectric constant material to represent the healthy tissue and high dielectric constant material to represent the tumor is used. Firstly, the measurements are made without tumor in the phantom. Then, the tumor-mimicking object is located to the phantom. In the measurements, both the PMA and DRH antennas are used respectively. These antennas are ultra-wideband and directional. They have narrow beamwidth and stable directional pattern at the interval of 3-10 GHz. According to the return loss results, the reflected energy increases when the antenna gets close to the tumor. Therefore, it can be said that the scattering parameters give important information about the tumor. According to the obtained results in this study, it can be said that the performance of the compact-sized PMA is better than the DRH antenna having larger size.