5 April 2019 in Journal of Astronomical Telescopes, Instruments, and Systems
Far-infrared astronomy, defined broadly as encompassing science at wavelengths of 30 to , is an invaluable tool in understanding all aspects of our cosmic origins. Tracing its roots to the late 1950s, with the advent of infrared detectors sensitive enough for astronomical applications, far-infrared astronomy has developed from a niche science, pursued by only a few teams of investigators, to a concerted worldwide effort pursued by hundreds of astronomers, targeting areas ranging from the origins of our Solar System to the ultimate origin of the Universe.
31 May 2019 in Journal of Astronomical Telescopes, Instruments, and Systems
Lynx is an observatory with an x-ray optic with the same focal length of 10 m as Chandra.1 It will have a similar angular resolution as Chandra of 0.5 arc sec but will have orders of magnitude more area and greater off-axis angular resolution, allowing for substantially deeper observations to study arc second astrophysical features in crowded regions of the sky.
1 October 2025 in Journal of Astronomical Telescopes, Instruments, and Systems
We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.
1 July 2025 in Journal of Astronomical Telescopes, Instruments, and Systems
In Pathways to Discovery in Astronomy and Astrophysics for the 2020s1 (hereinafter Astro2020), the Astronomical Decadal Survey recommended a new class of space observatories: astrophysics Probes. The scale of the Probes fills the gap between MIDEXs on the smaller side (e.g., SPHEREx for a recent example2) and Flagship Missions (e.g., JWST3 and HWO4). NASA responded with a call for concept proposals for X-ray and far-infrared (far-IR) Probes that were due in November 2023. With a $1.5 billion cost cap, Probes can accomplish more ambitious science than MIDEXs and launch more frequently than Flagship missions—perhaps one per decade. This higher cadence than Flagships (which have 2+ decade development and implementation phases) and intermediate scale enables NASA both to take advantage of maturing technologies and to have Explorer-like principal investigator (PI) science and community-driven general observer (GO) and guest investigator (GI) science programs. Indeed, the APEX Announcement of Opportunity mandated that at least 70% of observing time be reserved for GO science and that all PI science data be made available rapidly for GI science. The PI-managed cost cap for Probes is $1.0 billion, with $500 million reserved for the launch vehicle and services (∼$150 million) and administration (by NASA) of competed GO and GI science (∼$350 million).
14 August 2025 in Journal of Astronomical Telescopes, Instruments, and Systems
The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6×6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm2 at 1 keV and 424 cm2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.
29 December 2017 in Journal of Astronomical Telescopes, Instruments, and Systems
Hitomi, formerly known as ASTRO-H, was the sixth Japanese x-ray astronomy satellite and was developed under extensive international collaboration between Japan and the United States with European and Canadian participation.1 The soft x-ray spectrometer (SXS)2,3 was a cryogenic high-resolution x-ray spectrometer onboard Hitomi, utilizing an x-ray microcalorimeter array.4 Operated at 50 mK, it was designed to achieve a resolving power of 1000 or larger at 6 keV. The detector array was cooled to 50 mK using a three-stage adiabatic demagnetization refrigerator (ADR).5 The detector assembly (DA)6 and the ADR composed a modular unit called a calorimeter spectrometer insert (CSI). The cooling chain from room temperature to the ADR heat sink consisted of two-stage Stirling-cycle (2ST) cryocoolers,7 a Joule–Thomson (JT) cryocooler,7 and superfluid liquid helium (LHe). The lifetime requirement for nominal operation was 3 years (when launched with a minimum of 30 L of LHe), and at least for 9 months in the case of failure of a single cryocooler. It was also designed to operate even when the LHe was depleted.5,8 The CSI, the aperture assembly with optical/infrared blocking filters,9 and control electronics for the ADR and the filter heaters were developed by NASA and the University of Wisconsin, and JAXA was responsible for the cooling system from room temperature to the ADR heat sink and cryocooler drive electronics, which were manufactured by Sumitomo Heavy Industries, Ltd. (SHI), with contribution by ESA.