Natan Augusto Vieira Bulgarelli

Natan Augusto Vieira Bulgarelli

Auto-generated profile, based on publicly available information

Natan Augusto Vieira Bulgarelli

Center for Energy and Petroleum Studies, Universidade Estadual de Campinas, Campinas, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2024 in Geoenergy Science and Engineering
Verified
Journal Article
Closed access
WVWilliam Monte Verde
William Monte Verde
EKEllen Kindermann
Ellen Kindermann
NBNatan Augusto Vieira Bulgarelli
Natan Augusto Vieira Bulgarelli
LPLuiz Fernando Pastre
Luiz Fernando Pastre
BFBernardo Foresti
Bernardo Foresti
ABAntonio Carlos Bannwart
Antonio Carlos Bannwart

16 January 2025 in Physica A: Statistical Mechanics and its Applications
Verified
Journal Article
Closed access
LCLuiz Eduardo Czelusniak
Luiz Eduardo Czelusniak
IMIvan Talão Martins
Ivan Talão Martins
LCLuben Cabezas-Gómez
Luben Cabezas-Gómez
NBNatan Augusto Vieira Bulgarelli
Natan Augusto Vieira Bulgarelli
WVWilliam Monte Verde
William Monte Verde
MCMarcelo Souza de Castro
Marcelo Souza de Castro

20 February 2020 in Journal of Offshore Mechanics and Arctic Engineering
Verified
Journal Article
Closed access
PDF file
NBNatan Augusto Vieira Bulgarelli
Natan Augusto Vieira Bulgarelli
JBJorge Luiz Biazussi
Jorge Luiz Biazussi
WVWilliam Monte Verde
William Monte Verde
MCMarcelo Souza de Castro
Marcelo Souza de Castro
ABAntonio Carlos Bannwart
Antonio Carlos Bannwart
Despite the common presence of water in oil production, just recently, the scientific community has devoted efforts to studying the influence of emulsion phenomena effects related to oil production using pumps. In the context of this study of phase inversion phenomena, the influence of viscosities and rotational speeds in electrical submersible pumps (ESPs) are evaluated as part of this effort. This study is aimed at investigating the influence of viscosity in phase inversion phenomena. An eight-stage ESP was tested with three different rotational speeds and two different oil viscosities for the best efficiency point (BEP) flow rates. Initially, the total flow rate was obtained in relation to BEP using ESP performance curves for pure oil at 52 cP and 298 cP and rotational speeds of 800 rpm, 1200 rpm, and 2400 rpm. The total flow rate was kept constant and the water cut was increased from 0 to 100%. The inversion phase phenomenon was detected by performance improvement when the water cut increased. The factors analyzed were the head and efficiency of the ESP as a function of the water cut. The phase inversion experimental data obtained in this study were compared with literature models for horizontal pipes. The results of this comparison presented satisfactory agreement. The phase inversion phenomena occur in all eight stages at the same time. Hysteresis was observed in ESPs for oil viscosity of 52 cP and rotating speed of 800 rpm and 1200 rpm.

22 November 2024 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
NBNatan Augusto Vieira Bulgarelli
Natan Augusto Vieira Bulgarelli
LBLetícia Bizarre
Letícia Bizarre
WVWilliam Monte Verde
William Monte Verde
APAndrey Felipe Casas Pulido
Andrey Felipe Casas Pulido
MCMarcelo Souza de Castro
Marcelo Souza de Castro

1 May 2026 in Journal of Pipeline Science and Engineering
Verified
Journal Article
Open access
JSJaqueline Diniz da Silva
Jaqueline Diniz da Silva
Rodolfo PerissinottoRodolfo Perissinotto
Rodolfo Perissinotto
NBNatan A.V. Bulgarelli
Natan A.V. Bulgarelli
WVWilliam Monte Verde
William Monte Verde
MCMarcelo S. Castro
Marcelo S. Castro

15 December 2025 in SPE Journal
Verified
Journal Article
Closed access
MGM. H. C. Garros
M. H. C. Garros
NBN. A. V. Bulgarelli
N. A. V. Bulgarelli
JJJ. C. F. Johner
J. C. F. Johner
WVWilliam Monte Verde
William Monte Verde
MCMarcelo Souza de Castro
Marcelo Souza de Castro
Summary: Polymer solutions are essential in enhanced oil recovery (EOR) for flooding applications but are susceptible to mechanical degradation, which severely impacts its rheological behavior. In this study, we examine the degradation of sulfonated polyacrylamide (SPAM) in a flow loop simulating an oil production system with an electrical submersible pump (ESP). The effects of the non-Newtonian fluid on ESP performance were analyzed under different operational conditions of flow rate and rotational speed. The results identified that the ESP was not the primary contributor in the tested conditions, with the globe valve differential pressure as the most relevant contributor. The ESP exhibited a significant head reduction due to the solution’s effective viscosity. However, the required shaft power remained unchanged, as strong shear rates on the impeller’s external surface reduced viscosity due to the shear-thinning behavior of the solution. A model based on the first Newtonian plateau viscosity successfully estimated ESP performance and provided the shear rates within the pump. The head losses were attributed to low shear rates in the ESP diffuser and impeller channels, which can be associated with the increment of viscosity and friction losses.