Tommaso Cambiaghi

Tommaso Cambiaghi

Auto-generated profile, based on publicly available information

Tommaso Cambiaghi

Division of Vascular Surgery, "Vita-Salute" University, Scientific Institute H. San Raffaele, Milan, Italy

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
LBLuca Bertoglio
Luca Bertoglio
TCTommaso Cambiaghi
Tommaso Cambiaghi
CFCiro Ferrer
Ciro Ferrer
DBDomenico Baccellieri
Domenico Baccellieri
FVFabio Verzini
Fabio Verzini
Yamume TshombaYamume Tshomba
Yamume Tshomba

9 January 2018 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
LBLuca Bertoglio
Luca Bertoglio
DLDiletta Loschi
Diletta Loschi
TCTommaso Cambiaghi
Tommaso Cambiaghi
DMDaniele Mascia
Daniele Mascia
AKAndrea KAHLBERG
Andrea KAHLBERG
RCRoberto Chiesa
Roberto Chiesa
Purpose: To evaluate the 1-year outcomes of thoracoabdominal aortic aneurysm (TAAA) repair using fenestrated and branched stent-grafts and a novel balloon-expandable covered stent. Methods: Between March 2015 and January 2017, 18 patients (median age 74.7 years; 14 men) received 43 LifeStream balloon-expandable covered stents in conjunction with Zenith fenestrated/branched stent-grafts to bridge 11 celiac trunks, 8 superior mesenteric arteries, and 24 renal arteries (total 32 fenestrations and 11 branches). Results: Stent delivery and deployment was successful in all cases. At 30 days, 5 patients presented with perifenestration endoleaks (type IIIc) secondary to inadequate sealing of the LifeStream covered stent in 7 (22%) of 32 fenestrations. No type IIIc endoleaks were reported in the branched cases. Four patients had a secondary endovascular reintervention with proximal relining by means of a bare balloon-expandable stent at the perifenestration transition area, with complete resolution of the endoleak at 1-year follow-up. One patient refused reintervention. The last 4 fenestrated stent-grafts of this series had prophylactic perifenestration bare stent relining with no evidence of type IIIc endoleaks at imaging. At a median follow-up of 14.1 months (interquartile range 11, 22), the 12-month LifeStream patency rate was 100%. Conclusion: This single-center preliminary experience with the LifeStream balloon-expandable covered stent in fenestrated/branched stent-grafts for TAAA repairs demonstrated good patency; however, an unexpectedly high rate of type IIIc endoleaks was observed. These endoleaks were resolved with reintervention or during the index procedure by proximal relining with a bare balloon-expandable stent, achieving adequate perifenestration sealing.

1 July 2018 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
LBLuca Bertoglio
Luca Bertoglio
DMDaniele Mascia
Daniele Mascia
TCTommaso Cambiaghi
Tommaso Cambiaghi
AKAndrea KAHLBERG
Andrea KAHLBERG
GMGermano Melissano
Germano Melissano
RCRoberto Chiesa
Roberto Chiesa

1 May 2018 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
LBLuca Bertoglio
Luca Bertoglio
DMDaniele Mascia
Daniele Mascia
TCTommaso Cambiaghi
Tommaso Cambiaghi
AKAndrea KAHLBERG
Andrea KAHLBERG
Yamume TshombaYamume Tshomba
Yamume Tshomba
RCRoberto Chiesa
Roberto Chiesa

16 March 2017 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
TCTommaso Cambiaghi
Tommaso Cambiaghi
Andrea SpertinoAndrea Spertino
Andrea Spertino
LBLuca Bertoglio
Luca Bertoglio
RCRoberto Chiesa
Roberto Chiesa
Purpose: To present a Supera stent fracture following treatment of popliteal artery stenosis. Case Report: A 60-year-old man previously treated with angioplasty/stenting of a popliteal artery lesion with a Supera stent presented at 8 months with in-stent occlusion that proved to be secondary to stent fracture. Conclusion: Supera interwoven nitinol stents, despite having higher radial force and conformability than classic tube stents, are not free from fracture. Moreover, due to their peculiar structure, a break in these stents results in complete loss of integrity and consequent device collapse, thus jeopardizing endovascular recanalization and relining.

20 August 2016 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
AKAndrea KAHLBERG
Andrea KAHLBERG
MMMatteo Montorfano
Matteo Montorfano
TCTommaso Cambiaghi
Tommaso Cambiaghi
LBLuca Bertoglio
Luca Bertoglio
GMGermano Melissano
Germano Melissano
RCRoberto Chiesa
Roberto Chiesa
Purpose: To present stent-graft treatment of parietal thrombus in the ascending aorta. Case Report: A 64-year-old man with no history of vascular disease developed a right cerebral hemisphere transient ischemic attack and was diagnosed with mural thrombosis of the ascending aorta involving the greater curvature just proximal to the origin of the innominate artery. He was treated for 2 months with anticoagulants, but new imaging studies showed significant increase in the size of the thrombus and an irregular aspect. The thrombus was excluded from the aortic blood flow by deployment of a custom-made stent-graft in the ascending aorta, with embolic protection of the right internal carotid artery. At 6 months, the patient was well, and the thrombus in the ascending aorta appears to be completely excluded by the stent-graft. Conclusion: In highly selected cases, custom-made thoracic stent-grafts may be used for stabilization and exclusion of symptomatic ascending aorta parietal thrombosis to prevent progression and recurrent embolization.