To investigate the mechanical behaviors of steel fibre reinforced concrete (SFRC) segments which are firstly used in the test section of the Shanghai Rail Transit Project Line 6, and to propose some useful suggestions for design and construction, a numerical analysis and field test are conducted. The contents of this study involve: (1) the behaviors of the segments against the jacking force, (2) the occurrence and development of cracks, the distribution of stress and strain of segment body, and (3) the distribution of stress and strain in circumferential joints of lining. The results show that safety against the jacking force of shield and the distribution of tensile strain in segment body and joint meet the requirement of design and construction. No cracks have been found in segments under the construction load. This indicates that the steel fibre provides the concrete of the segment with an improved crack resistance. It should be noticed that, although there is no cracks, the maximum tensile strain of rabbets of circumferential joints is much larger than the critical strain of the concrete. It is suggested that the rabbets should be reinforced in design.
The soft soil within the pipe roof ahead of excavation face was generally reinforced for retaining the face stability, but the Beihong-Road tunnel in Shanghai constructed recently is the first case to adopt pipe roof method without reinforcing the saturated soft soil. It is made of 80 phi 970 steel pipes with interlocks forming a rectangular type of pipe curtain. Stability of the excavation face and the controlling of ground settlement during construction are obtained by box grid and steel pipe roof. The heave of ground surface is produced during the box grid extruding into the soil as culvert box jacking forward. To study the mechanism of pipe roof, such as ground heave magnitude, range, uplift force and steel pipe flexural rigidity, pipe roof is simplified as longitudinal grade beam. The pipes ahead of grid bear uplift force within the range of passive sliding zone, and other parts of them lay on elastic foundation. This model can calculate heave magnitude, range and uplift force, etc.
Thirty-three experiments were performed in a scale of 1:6th tunnel model. The purpose of the experiments was to investigate the behaviours of smoke propagation and temperature distribution and to propose an effective ventilation measure during fire fighting in a long sized road tunnel. As a fire source, an oil pool was used. The temperature, air velocity and pressure in the tunnel were recorded continuously. The results showed that the temperature, pressure and smoke flow in the tunnel varying significantly with the ventilation measures. Also, the proper ventilation measures could rapidly reduce the temperature for fire fighter and victims and improve air quality and visibility within the tunnel. In addition, the basic ventilation measure was experimentally established.