Jonathan Derek Wiles

Jonathan Derek Wiles

Auto-generated profile, based on publicly available information

Jonathan Derek Wiles

School of Human and Life Sciences, Canterbury Christ Church University, Canterbury, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2009 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
JWJonathan Derek Wiles
Jonathan Derek Wiles
DCDamian A. Coleman
Damian A. Coleman
ISIan L. Swaine
Ian L. Swaine

16 November 2016 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
JWJonathan D. Wiles
Jonathan D. Wiles
NGNatalie Goldring
Natalie Goldring
DCDamian Coleman
Damian Coleman

8 August 2022 in Journal Of Hypertension
Verified
Journal Article
Closed access
JEJamie J. Edwards
Jamie J. Edwards
JWJonathan Wiles
Jonathan Wiles
JOJamie O’dRiscoll
Jamie O’dRiscoll
Objective: Isometric exercise training (IET) is established as an effective antihypertensive intervention. Despite this, the physiological mechanisms driving blood pressure (BP) reductions following IET are not well understood. Therefore, we aimed to perform the first meta-analysis of the mechanistic changes measured following IET. Methods: PubMed, Cochrane library and SPORTDiscus were systematically searched for randomized controlled trials published between January 2000 and December 2021 reporting the effects of IET on resting BP and at least one secondary mechanistic parameter following a short-term intervention (2–12 weeks). Results: Eighteen studies with a pooled sample size of 628 participants were included in the final analysis. IET produced significant reductions in resting systolic and diastolic BP of 9.35 mmHg (95% confidence interval [CI] = −7.80 to −10.89, P < 0.001) and 4.30 mmHg (CI = −3.01 to −5.60, P < 0.001), respectively. Mechanistically, IET produced a statistically significant reduction in resting heart rate (mean difference [MD]: −1.55 bpm, CI = −0.14 to −2.96, P = 0.031) and a significant increase in stroke volume (MD: 6.35 ml, CI = 0.35 to 12.60, P = 0.038), with no significant change in cardiac output. Conversely, total peripheral resistance (TPR) significantly decreased following IET (MD: −100.38 dyne s−1 cm5, CI = −14.16 to −186.61, P = 0.023), with significant improvements in the low frequency to high frequency heart rate variability ratio (MD: −0.41, CI = −0.09 to −0.73, P = 0.013) and baroreceptor reflex sensitivity (MD: 7.43 ms/mmHg, P < 0.001). Conclusion: This work demonstrates that a reduction in TPR, potentially mediated through enhanced autonomic vasomotor control, is primarily responsible for BP reductions following IET. Furthermore, this novel analysis suggests wall squat interventions to be the most effective IET mode, with clinically relevant differences in BP reductions compared to handgrip and leg extension IET; although future direct comparative research is required.

1 March 2018 in Medicine
Verified
Journal Article
Open access
JWJonathan D. Wiles
Jonathan D. Wiles
KTKatrina Taylor
Katrina Taylor
DCDamian Coleman
Damian Coleman
RSRajan Sharma
Rajan Sharma
JOJamie M. O’dRiscoll
Jamie M. O’dRiscoll
Few studies have investigated the relative safety of prescribing isometric exercise (IE) to reduce resting blood pressure (BP). This study aimed to ascertain the safety of the hemodynamic response during an IE wall squat protocol.Twenty-six hypertensive (BP of 120-139 mm Hg systolic and/or 80-90 mm Hg diastolic) males (45 ± 8 years; 1.78 ± 0.07 m; 89.7 ± 12.3 kg; mean ± SD), visited the laboratory on 2 separate occasions. Heart rate (HR) and BP were measured at rest and continuously throughout exercise. In visit 1, participants completed a continuous incremental isometric wall squat exercise test, starting at 135° of knee flexion, decreasing by 10° every 2 minutes until 95° (final stage). Exercise was terminated upon completion of the test or volitional fatigue. The relationship between knee joint angle and mean HR was used to calculate the participant-specific knee joint angle required to elicit a target HR of 95% HRpeak. This angle was used to determine exercise intensity for a wall squat training session consisting of 4 × 2 minute bouts (visit 2).Systolic BPs during the exercise test and training were 173 ± 21 mm Hg and 171 ± 19 mm Hg, respectively, (P > .05) and were positively related (r = 0.73, P < .05) with ratio limits of agreement (LoA) of 0.995 ×/÷ 1.077. Diastolic BPs were 116 ± 14 mm Hg and 113 ± 11 mm Hg, respectively, (P > .05) and were positively related (r = 0.42, P < .05) with ratio LoA of 0.99 ×/÷ 1.107. No participant recorded a systolic BP > 250 mm Hg. Diastolic BP values > 115 mm Hg were recorded in 12 participants during the incremental test and 6 participants during the training session. Peak rate pressure product was 20681 ± 3911 mm Hg bpm during the IE test and was lower (18074 ± 3209 mm Hg bpm) during the IE session (P = .002). No adverse effects were reported.Based on the current ACSM guidelines for aerobic exercise termination, systolic BP does not reach the upper limit during IE in this population. Diastolic BP exceeds 115 mm Hg in some during the IE protocol, which may suggest the need to individualise IE training prescription in some with suboptimal BP control. Future research is required to ascertain if IE requires modified BP termination guidelines.

5 March 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JLJohn W. D. Lea
John W. D. Lea
JOJamie M. O’dRiscoll
Jamie M. O’dRiscoll
DCDamian A. Coleman
Damian A. Coleman
JWJonathan D. Wiles
Jonathan D. Wiles
Isometric exercise (IE) interventions are an effective non-medical method of reducing arterial blood pressure (BP). Current methods of prescribing and controlling isometric exercise intensity often require the use of expensive equipment and specialist knowledge. However, ratings of perceived exertion (RPE) may provide a more accessible means of monitoring exercise intensity. Therefore, the aim of this study was to assess the validity of a specific Isometric Exercise Scale (IES) during a continuous incremental IE test. Twenty-nine male participants completed four incremental isometric wall squat tests. Each test consisted of five 2-min stages of progressively increasing workload. Workload was determined by knee joint angle from 135° to 95°. The tests were continuous with no rest periods between the stages. Throughout the exercise protocol, RPE (IES and Borg’s CR-10), heart rate and blood pressure were recorded. A strong positive linear relationship was found between the IES and the CR-10 (r = 0.967). Likewise, strong positive relationships between the IES and wall squat duration (r = 0.849), HR (r = 0.819) and BP (r = 0.841) were seen. Intra-class correlation coefficients and coefficients of variations for the IES ranged from r = 0.81 to 0.91 and 4.5–54%, respectively, with greater reliability seen at the higher workloads. The IES provides valid and reliable measurements of RPE, exercise intensity, and the changes in physiological measures of exertion during continuous incremental IE; as such, the IES can be used as an accessible measure of exercise intensity during IE interventions.

28 January 2022 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
HSHarry T. Swift
Harry T. Swift
JOJamie M. O’dRiscoll
Jamie M. O’dRiscoll
DCDamian D. Coleman
Damian D. Coleman
ACAnthony De Caux
Anthony De Caux
JWJonathan D. Wiles
Jonathan D. Wiles