Dipit Sahu

Dipit Sahu

Auto-generated profile, based on publicly available information

Dipit Sahu

Sir H.N. Reliance Foundation Hospital and Research Centre, Mumbai, India

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
SHS. Ashfaq Hasan
S. Ashfaq Hasan
CCCari L. Cordell
Cari L. Cordell
RRRussell B. Rauls
Russell B. Rauls
MBMark S. Bailey
Mark S. Bailey
DSDipit Sahu
Dipit Sahu
LSLarry John Suva
Larry John Suva

1 May 2020 in Journal of Clinical Orthopaedics and Trauma
Verified
Journal Article
Closed access
DSDipit Sahu
Dipit Sahu
TATushar Agrawal
Tushar Agrawal
VRVaibhavi Rathod
Vaibhavi Rathod
VBVaibhav Bagaria
Vaibhav Bagaria

27 October 2009 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
JOJong-Keon Oh
Jong-Keon Oh
DSDipit Sahu
Dipit Sahu
YAYoon-Ho Ahn
Yoon-Ho Ahn
SLSung-Jae Lee
Sung-Jae Lee
STSadami Tsutsumi
Sadami Tsutsumi
Chang-Wug OhChang-Wug Oh
Chang-Wug Oh
In compression plating, anatomical reduction and compression across the fracture site are the basic principles necessary to achieve primary bone healing. However, varying amounts of gap at the fracture site frequently occur due to technical pitfalls, such as overbending of the plate and inaccurate reduction, and due to the fracture configuration itself. Little is known as to how fracture gap affects stability of the bone–plate construct. We analyzed the effects of fracture gap size (1 and 4 mm) and bone defect (25%, 50%, 75%, 100%) on the biomechanical stability of the compression plate–bone construct through validated finite element analysis. The stiffnesses of eight different models were compared with the stiffness of an ideally compressed model (0 mm/0%). Stress concentration in form of peak von Mises stress (PVMS) was also evaluated. The decrease in stiffness depended mainly on the depth of bone defect. The decrease in stiffness was similar in models with the same defect and different gap size. Considerably more stress was concentrated around the central hole of the plate in gap models with the depth of bone defects of 75% and 100% than with smaller defects. We concluded that even a thin fracture gap (1 mm) with no contact between the fracture after plating decreases stiffness exponentially; contact at the fracture surfaces of ≥50% was necessary to avoid undue stress concentration in the plate. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:462–467, 2010

1 April 2014 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
DSDipit Sahu
Dipit Sahu
DHDavid M. Holmes
David M. Holmes
JFJames S. Fitzsimmons
James S. Fitzsimmons
ATAndrew R. Thoreson
Andrew R. Thoreson
LBLawrence J. Berglund
Lawrence J. Berglund
SOShawn W. O’dRiscoll
Shawn W. O’dRiscoll

1 January 2011 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
PDF file
JOJong-Keon Oh
Jong-Keon Oh
JHJin-Ho Hwang
Jin-Ho Hwang
DSDipit Sahu
Dipit Sahu
SJSeung-Hyub Jun
Seung-Hyub Jun
A second staged operation using temporary bridging external fixation (TBEF) has been widely used in patients with periarticular complex fracture, yet few papers have been published on the related complications. The purpose of this study was to report the complication rate and pitfalls directly related to TBEF through a retrospective study and to suggest some solutions. Fifty-nine cases that were treated by using TBEF were studied among 195 periarticular complex fractures. We retrospectively collected the clinical and radiological data and then the study data was evaluated for 1) cases with unsatisfactory restoration of length, 2) cases with deep infection caused by half pins invading the zone of definitive fixation, and 3) neurovascular injuries related to half pins. Complications were observed in 7/59 cases (11%). Problems related to the achievement of length were observed in one case of distal tibia fracture and 2 cases of distal femur fracture. Half pin related infection was observed in 2 cases of distal femur fracture. Neurovascular injury (medial calcaneal nerve injury in a distal tibia fracture) was observed in 2 cases. Among 7 complications, four were related to using TBEF in distal femur fracture. This is because the abundant leg muscles have strong deforming force and infection might be increased due to frequent irritation by the half pins. TBEF is a simple procedure with several advantages. However, complications might be observed if certain principles are not followed. It is thought that many complications due to TBEF can be reduced if the half pins are not inserted in the zone of injury, restoration of length is fully achieved and the neurovascular characteristics are carefully considered. In particular, much more caution is needed in the distal femur, which has abundant muscles surrounding it.

31 August 2014 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
DSDipit Sahu
Dipit Sahu
RFRobert Fullick
Robert Fullick
AGAntonios Giannakos
Antonios Giannakos
LLLaurent Lafosse
Laurent Lafosse