Jennifer J. Peters

Jennifer J. Peters

Auto-generated profile, based on publicly available information

Jennifer J. Peters

Department of Biomedical Engineering, Duke University, Durham, NC, USA

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2023 in Proceedings of SPIE
Verified
Conference Paper
Open access
QGQitong Gao
Qitong Gao
SSStephen Schmidt
Stephen Schmidt
ACAfsana Chowdhury
Afsana Chowdhury
GFGuangyu Feng
Guangyu Feng
JPJennifer J. Peters
Jennifer J. Peters
MPMiroslav Pajic
Miroslav Pajic
Deep brain stimulation (DBS) has shown great promise toward treating motor symptoms caused by Parkinson's disease (PD), by delivering electrical pulses to the Basal Ganglia (BG) region of the brain. However, DBS devices approved by the U.S. Food and Drug Administration (FDA) can only deliver continuous DBS (cDBS) at a fixed amplitude; this energy inefficient operation reduces battery lifetime of the device, cannot adapt treatment dynamically for activity, and may cause significant side-effects (e.g., gait impairment). In this work, we introduce an offline reinforcement learning (RL) framework, allowing the use of past clinical data to train an RL policy to adjust the stimulation amplitude in real time, with the goal of reducing energy use while maintaining the same level of treatment (i.e., control) efficacy as cDBS. Moreover, clinical protocols require the safety and performance of such RL controllers to be demonstrated ahead of deployments in patients. Thus, we also introduce an offline policy evaluation (OPE) method to estimate the performance of RL policies using historical data, before deploying them on patients. We evaluated our framework on four PD patients equipped with the RC+S DBS system, employing the RL controllers during monthly clinical visits, with the overall control efficacy evaluated by severity of symptoms (i.e., bradykinesia and tremor), changes in PD biomakers (i.e., local field potentials), and patient ratings. The results from clinical experiments show that our RL-based controller maintains the same level of control efficacy as cDBS, but with significantly reduced stimulation energy. Further, the OPE method is shown effective in accurately estimating and ranking the expected returns of RL controllers.

19 October 2023 in Brain Stimulation
Verified
Journal Article
Open access
KPKay Palopoli-Trojani
Kay Palopoli-Trojani
SSStephen Schmidt
Stephen Schmidt
KBKarley D. Baringer
Karley D. Baringer
TSTheodore A. Slotkin
Theodore A. Slotkin
JPJennifer J. Peters
Jennifer J. Peters
WGWarren M. Grill
Warren M. Grill
Traditional deep brain stimulation (DBS) at fixed regular frequencies (>100 Hz) is effective in treating motor symptoms of Parkinson's disease (PD). Temporally non-regular patterns of DBS are a new parameter space that may help increase efficacy and efficiency. To compare the effects of temporally non-regular patterns of DBS to traditional regularly-spaced pulses. We simultaneously recorded local field potentials (LFP) and monitored motor symptoms (tremor and bradykinesia) in persons with PD during DBS in subthalamic nucleus (STN). We quantified both oscillatory activity and DBS local evoked potentials (DLEPs) from the LFP. Temporally non-regular patterns were as effective as traditional pulse patterns in modulating motor symptoms, oscillatory activity, and DLEPs. Moreover, one of our novel patterns enabled recording of longer duration DLEPs during clinically effective stimulation. Stimulation gaps of 50 ms can be used to increase efficiency and to enable regular assessment of long-duration DLEPs while maintaining effective symptom management. This may be a promising paradigm for closed-loop DBS with biomarker assessment during the gaps.

1 January 1998 in Environmental Toxicology and Chemistry
Verified
Journal Article
Closed access
PDF file
TPThomas W. Purcell
Thomas W. Purcell
JPJennifer J. Peters
Jennifer J. Peters

10 December 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TDTyler K. Drake
Tyler K. Drake
TSTejen Shah
Tejen Shah
JPJennifer J. Peters
Jennifer J. Peters
AWAdam Wax
Adam Wax
DKDavid F. Katz
David F. Katz
We present a novel approach for measuring topical microbicide gel dilution using optical imaging. The approach compares gel thickness measurements from fluorimetry and multiplexed low coherence interferometry in order to calculate dilution of a gel. As a microbicide gel becomes diluted at fixed thickness, its mLCI thickness measurement remains constant, while the fluorimetry signal decreases in intensity. The difference between the two measurements is related to the extent of gel dilution. These two optical modalities are implemented in a single endoscopic instrument that enables simultaneous data collection. A preliminary validation study was performed with in vitro placebo gel measurements taken in a controlled test socket. It was found that change in slope of the regression line between fluorimetry and mLCI based measurements indicates dilution. A dilution calibration curve was then generated by repeating the test socket measurements with serial dilutions of placebo gel with vaginal fluid simulant. This methodology can provide valuable dilution information on candidate microbicide products, which could substantially enhance our understanding of their in vivo functioning.

11 August 2025 in Brain Stimulation
Verified
Journal Article
Open access
KKKarthik Kumaravelu
Karthik Kumaravelu
SSStephen Schmidt
Stephen Schmidt
YZYi Zhao
Yi Zhao
AVAllison Vittert
Allison Vittert
BSBrandon D. Swan
Brandon D. Swan
WGWarren M. Grill
Warren M. Grill
Deep brain stimulation (DBS) of the ventral intermediate nucleus (VIM) of the thalamus (TH) is an effective therapy for suppressing tremor. One of the critical challenges to optimizing VIM-DBS therapy is the lack of robust neural biomarkers that correlate well with tremor. To quantify biomarkers for tremor using intraoperative TH local field potential (LFP) recorded from DBS electrodes. Further, we used computational modeling to understand the biophysical basis of the recorded LFP signal. We simultaneously recorded intraoperative TH LFP and tremor from the hand dorsum (32 participants) and during DBS at different frequencies (16 participants). Then, we simulated the effects of DBS and spatial distribution of tremor cells on calculated LFPs in a TH model. There was a moderate correlation between tremor and LFP spectral power in the theta and alpha bands (r = 0.445 and 0.389, respectively). There was a strong correlation between tremor and peak coherence between LFP and tremor signal (r = 0.559). Postural tremor was decoded from the LFP signal with an area under the curve of ∼0.7. High frequency DBS reduced spectral power in the theta and alpha bands and tremor could be decoded from the LFP spectral power in the presence of DBS (0.429 goodness of fit R2). The theta power in the simulated LFP signal varied substantially with the specific location of the bipolar contact pair of the DBS electrode used for the LFP recordings as well as the spatial distribution of tremor cells. Theta power alone was not sufficient for prediction of tremor control. Simulations indicated that the number and distribution of tremor cells surrounding the DBS lead may explain the lack of a strong correlation between tremor and theta power.

23 April 2026 in Neuromodulation: Technology at the Neural Interface
Verified
Journal Article
Closed access
KTKathryn M. Turk
Kathryn M. Turk
KMKevin J. Mohsenian
Kevin J. Mohsenian
JPJennifer J. Peters
Jennifer J. Peters
DSDerek G. Southwell
Derek G. Southwell
WGWarren M. Grill
Warren M. Grill
NPNicole A. Pelot
Nicole A. Pelot