Rostislav Polasek

Rostislav Polasek

Auto-generated profile, based on publicly available information

Rostislav Polasek

Department of Cardiology, Regional Hospital Liberec, Husova, Liberec, Czech Republic

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2012 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
RPRostislav Polasek
Rostislav Polasek
PKPavel Kucera
Pavel Kucera
PNPavel Nedbal
Pavel Nedbal
TRTomas Roubicek
Tomas Roubicek
TBTomas Belza
Tomas Belza
JKJosef Kautzner
Josef Kautzner
Considerable proportion of patients does not respond to the cardiac resynchronization therapy (CRT). This study investigated clinical relevance of left ventricular electrode local electrogram delay from the beginning of QRS (QLV). We hypothesized that longer QLV indicating more optimal lead placement in the late activated regions is associated with the higher probability of positive CRT response.

12 May 2014 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
PDF file
RPRostislav Polasek
Rostislav Polasek
ISIvo Skalsky
Ivo Skalsky
DWDan Wichterle
Dan Wichterle
TMTomas Martinca
Tomas Martinca
JHJana Hanuliakova
Jana Hanuliakova
JKJosef Kautzner
Josef Kautzner
The left ventricular (LV) lead local electrogram (EGM) delay from the beginning of the QRS complex (QLV) is considered a strong predictor of response to cardiac resynchronization therapy. We have developed a method for fast epicardial QLV mapping during video-thoracoscopic surgery to guide LV lead placement. A three-port, video-thoracoscopic approach was used for LV free wall epicardial mapping and lead implantation. A decapolar electrophysiological catheter was introduced through one port and systematically attached to multiple accessible LV sites. The pacing lead was targeted to the site with maximum QLV. The LV free wall activation pattern was analyzed in 16 pre-specified anatomical segments. We implanted LV leads in 13 patients with LBBB or IVCD. The procedural and mapping times were 142 ± 39 minutes and 20 ± 9 minutes, respectively. A total of 15.0 ± 2.2 LV segments were mappable with variable spatial distribution of QLV-optimum. The QLV ratio (QLV/QRSd) at the optimum segment was significantly higher (by 0.17 ± 0.08, p < 0.00001) as compared to an empirical midventricular lateral segment. The LV lead was implanted at the optimum segment in 11 patients (at an adjacent segment in 2 patients) achieving a QLV ratio of 0.82 ± 0.09 (range 0.63–0.93) and 99.5 ± 0.6% match with intraprocedural mapping. Video-thoracoscopic LV lead implantation can be effectively and safely guided by epicardial QLV mapping. This strategy was highly successful in targeting the selected LV segment and resulted in significantly higher QLV ratios compared to an empirical midventricular lateral segment.

1 January 2010 in Cor et Vasa
Verified
Journal Article
Open access
PDF file
RPRostislav Polášek
Rostislav Polášek
PNPavel Nedbal
Pavel Nedbal
LJLukáš Jaworski
Lukáš Jaworski
PKPavel Kučera
Pavel Kučera
KSKlára Skoupá
Klára Skoupá
DHDavid Horák
David Horák
C?l: Porovnat po?et pacient? indikovan?ch k implantaci ICD v prim?rn? prevenci n?hl? srde?n? smrti podle star?ch (2005) a nov?ch (2009) doporu?en? ?esk? kardiologick? spole?nosti (?KS) u pacient? po prod?lan?m infarktu myokardu s elevacemi ?se...