24 September 2021 in Light: Science & Applications
In vivo fluorescence imaging in the second near-infrared window (NIR-II) has been considered as a promising technique for visualizing mammals. However, the definition of the NIR-II region and the mechanism accounting for the excellent performance still need to be perfected. Herein, we simulate the photon propagation in the NIR region (to 2340 nm), confirm the positive contribution of moderate light absorption by water in intravital imaging and perfect the NIR-II window as 900–1880 nm, where 1400–1500 and 1700–1880 nm are defined as NIR-IIx and NIR-IIc regions, respectively. Moreover, 2080–2340 nm is newly proposed as the third near-infrared (NIR-III) window, which is believed to provide the best imaging quality. The wide-field fluorescence microscopy in the brain is performed around the NIR-IIx region, with excellent optical sectioning strength and the largest imaging depth of intravital NIR-II fluorescence microscopy to date. We also propose 1400 nm long-pass detection in off-peak NIR-II imaging whose performance exceeds that of NIR-IIb imaging, using bright fluorophores with short emission wavelength.
18 August 2023 in Nature Communications
The limited signal of long-wavelength near-infrared-II (NIR-II, 900–1880 nm) fluorophores and the strong background caused by the diffused photons make high-contrast fluorescence imaging in vivo with deep tissue disturbed still challenging. Here, we develop NIR-II fluorescent small molecules with aggregation-induced emission properties, high brightness, and maximal emission beyond 1200 nm by enhancing electron-donating ability and reducing the donor-acceptor (D-A) distance, to complement the scarce bright long-wavelength emissive organic dyes. The convincing single-crystal evidence of D-A-D molecular structure reveals the strong inhibition of the π-π stacking with ultralong molecular packing distance exceeding 8 Å. The delicately-designed nanofluorophores with bright fluorescent signals extending to 1900 nm match the background-suppressed imaging window, enabling the signal-to-background ratio of the tissue image to reach over 100 with the tissue thickness of ~4–6 mm. In addition, the intraluminal lesions with strong negatively stained can be identified with almost zero background. This method can provide new avenues for future long-wavelength NIR-II molecular design and biomedical imaging of deep and highly scattering tissues.
10 January 2022 in bioRxiv
High-definition fluorescence imaging of deep-buried organs is still challenging. Here, we develop bright fluorophores emitting to 1700 nm by enhancing electron donating ability and reducing donor-acceptor distance. In parallel, the heavy water functions as the solvent of the delicately designed fluorophores, effectively reducing the fluorescent signal loss caused by the absorption by water. The near-infrared-II (NIR-II, 900-1880 nm) emission is eventually recovered and extended beyond 1400 nm. Compared with the spectral range beyond 1500 nm, the one beyond 1400 nm gives a more accurate fluorescence visualization of the hollow organs, owing to the absorption-induced scattering suppression. In addition, the intraluminal lesions containing much water are simultaneously negatively stained, leading to a stark contrast for precise diagnosis. Eventually, the intraluminally perfused fluorescent probes are excreted from mice and thus no obvious side effects emerge. This general method can provide new avenues for future biomedical imaging of deep and highly scattering tissues.
14 February 2021 in bioRxiv
Uterine diseases seriously threaten the physical and mental health of women. The main principle, when clinicians adopt examinations, is to achieve efficient diagnosis without negative effect on the physical function including fertility. Hysterography in near-infrared (NIR) IIb window (1500-1700 nm) presents perceptibly enhanced signal to background ratio (SBR) and higher penetration capability compared with those beyond 1000 nm and 1300 nm, but lays down high requirements for the biosafety of fluorophores at the same time. Assisted by the biologically excretable aggregation-induced emission (AIE) dots, non-invasive NIR-IIb fluorescence hysterography visualized typical Y-shaped uteruses, real-time uterine peristalsis or the uterine lesions (mimetic disease statuses in clinic) in mouse models. Significantly, after intrauterine perfusion, the reproductive capacity was unimpaired via fertility assessment and histological analysis. This work could inspire some new ideas for non-invasive clinical diagnosis of uterine diseases and effectively promote the clinical translation of AIE dots.