Purpose: To employ optimal control for the numerical design of Chemical Exchange Saturation Transfer (CEST) saturation pulses to maximize contrast and stability against inhomogeneities.Theory and Methods: We applied an optimal control framework for the design pulse shapes for CEST saturation pulse trains. The cost functional minimized both the pulse energy and the discrepancy between the corresponding CEST spectrum and the target spectrum based on a continuous radiofrequency (RF) pulse. The optimization is subject to hardware limitations. In measurements on a 7 T preclinical scanner, the optimal control pulses were compared to continuous‐wave and Gaussian saturation methods. We conducted a comparison of the optimal control pulses with Gaussian, block pulse trains, and adiabatic spin‐lock pulses.Results: The optimal control pulse train demonstrated saturation levels comparable to continuous‐wave saturation and surpassed Gaussian saturation by up to 50 % in phantom measurements. In phantom measurements at 3 T the optimized pulses not only showcased the highest CEST contrast, but also the highest stability against field inhomogeneities. In contrast, block pulse saturation resulted in severe artifacts. Dynamic Bloch‐McConnell simulations were employed to identify the source of these artifacts, and underscore the robustness of the optimized pulses.Conclusion: In this work, it was shown that a substantial improvement in pulsed saturation CEST imaging can be achieved by using Optimal Control design principles. It is possible to overcome the sensitivity of saturation to B0 inhomogeneities while achieving CEST contrast close to continuous wave saturation.
Purpose: Optimal control (OC) chemical exchange saturation transfer (CEST) pulse design for singular pulses that can be used flexibly and robustly with high saturation at different duty cycles, saturation durations, and magnetic field strengths. Theory and Methods: An OC framework was developed to design a single‐pulse shape that can be flexibly applied for arbitrary pulse train parameters and outperform typically used CEST saturation pulse shapes. The pulse design was developed primarily with a continuous‐wave (CW) spectrum as the optimization target, but can be easily adapted to specific scenarios. The generalized OC pulse was evaluated through simulations, a phantom, and in vivo measurements on a 3 T clinical scanner. Performance was assessed in terms of contrast, robustness to field inhomogeneities, and resilience against artifacts such as Rabi oscillations and sidebands, compared to established saturation techniques. Results: Investigations showed that the generalized OC pulse achieved a contrast matching CW saturation and also functioned well under field inhomogeneities. Low‐pass filtering of the optimized pulse shape effectively suppressed artifacts outside the initial optimization frequency range, enabling generalization across different field strengths. Phantom experiments consistently showed higher contrast than Gaussian, Fermi, and adiabatic spin‐lock (aSL) pulses for various CEST agents covering most clinically relevant regimes. In vivo imaging demonstrated substantially enhanced CEST contrast for both creatine/phosphocreatine in muscle and amide proton transfer (APT) in the brain compared to Gaussian saturation. Conclusion: The generalized OC pulse provides a robust and flexible alternative to conventional CEST saturation strategies. Its integration into the open‐source Pulseq‐CEST framework supports simple reproducibility and a vendor‐independent implementation.
Purpose: Optimal Control (OC) CEST pulse design for singular pulses that can be used flexibly and robustly with high saturation at different duty cycles, saturation durations and magnetic field strengths. Theory and Methods: An OC framework was developed to design a single pulse shape that can be flexibly applied for arbitrary pulse train parameters and outperform typically used CEST saturation pulses shapes. The pulse design was developed primarily with a continuous wave spectrum (CW) as the optimization target, but can be easily adapted to specific scenarios. The generalized OC pulse was evaluated through simulations, phantom, and in vivo measurements on a 3 T clinical scanner. Performance was assessed in terms of contrast, robustness to field inhomogeneities, and resilience against artifacts such as Rabi oscillations and sidebands, compared to established saturation techniques. Results: Investigations showed that the generalized OC pulse achieved a contrast matching CW saturation and also functioned well under field inhomogeneities. Low-pass filtering of the optimized pulse shape effectively suppressed artifacts outside the initial optimization frequency range, enabling generalization across different field strengths. Phantom experiments consistently showed higher contrast than Gaussian, Fermi, and adiabatic spin-lock pulses for various CEST agents covering most clinically relevant regimes. In vivo imaging demonstrated substantially enhanced CEST contrast for both creatine/phosphocreatine in muscle and Amide Proton Transfer (APT) in brain compared to Gaussian saturation. Conclusion: The generalized OC pulse provides a robust and flexible alternative to conventional CEST saturation strategies. Its integration into the open-source Pulseq-CEST framework supports simple reproducibility and a vendor-independent implementation.
25 November 2025 in Magnetic Resonance in Medicine
Purpose: This work proposes a method for the simultaneous estimation of the exchange‐dependent relaxation rate and the longitudinal relaxation time from a single acquisition. Methods: A novel acquisition scheme was developed that combines CEST saturation with an inversion pulse and a Look‐Locker readout to capture the magnetization evolution starting from the inverse transient Z‐spectrum. The corresponding signal model, derived from the Bloch‐McConnell equations, describes both the transient Z‐spectrum and the Look‐Locker dynamics. A model‐based reconstruction approach is employed to jointly estimate and . The proposed method was validated using a numerical phantom and benchmarked against conventional CEST and Look‐Locker mapping in a phantom and in vivo on a clinical 3T scanner. Results: The joint estimation approach demonstrated strong agreement with ground truth and conventional methods across a wide range of and CEST parameters. The acquisition time was reduced by 20%–30% compared to standard CEST protocols, while providing a higher signal‐to‐noise ratio (SNR) in parameter maps. Conclusion: The proposed technique enables robust and efficient simultaneous quantification of CEST and in a single acquisition. It improves parameter map quality and reduces scan time, making it suitable for both phantom and in vivo imaging across a wide range of physiological conditions.
Purpose: To evaluate the repeatability of an extended multiparametric 7 T MRI protocol for voxel‐wise tissue characterization combining morphological, CEST, QSM, QTI, and Sodium contrasts. Methods: A repeatability study was performed in 12 volunteers without diagnosed neurological disease on a 7 T MRI system, using a comprehensive acquisition protocol with a combined acquisition time of 45:24 min, from which 45 contrast maps were derived. Quantitative repeatability was assessed using region‐based and voxel‐wise analyses. Precision and reliability were evaluated using the coefficient of variation (CV), repeatability coefficient (%RC), and intraclass correlation coefficient (ICC). Voxel‐wise agreement between scan–rescan images was assessed using Pearson correlation coefficients. Results: Across contrasts spanning morphological, CEST, QSM, QTI, and 23 Na imaging, %RC was below 20% for 20 contrasts, with mean CV below 5% for most. Repeatability was highest for MP2RAGE T 1 maps and QTI MD (CV ≈ 1%–2%; ICC up to 0.86) and lowest for 23 Na imaging (ICC < 0.6). CEST contrasts were highly repeatable at low saturation power but more variable at higher power (CV up to ≈8%). QSM contrasts showed moderate ICC (0.46–0.82). Voxel‐wise correlations exceeded r = 0.8 for most contrasts, confirming preserved spatial patterns across repeated scans. Conclusion: Multiparametric 7 T MRI enables reproducible voxel‐wise characterization of brain tissue across a wide range of contrasts. Despite variability in specific contrasts, the overall high repeatability and strong voxel‐wise agreement support the feasibility of voxel‐wise imaging approaches for quantitative brain imaging and provide a foundation for future applications in clinical research and neuroscience.