Representative Publications

View All Publications
20 July 2018 in Шпитальна хірургія. Журнал імені Л. Я. Ковальчука
Verified
Journal Article
Open access
PDF file
SPS. S. Podpriatov
S. S. Podpriatov
SPS. E. Podpryatov
S. E. Podpryatov
AMA. V. Makarov
A. V. Makarov
GMG. S. Marinsky
G. S. Marinsky
VTV. A. Tkachenko
V. A. Tkachenko
KLK. G. Lopatkina
K. G. Lopatkina
Мета роботи: розробити первинні вимоги для передклінічних досліджень зі створення електрозварного з’єднання в міжкишковому анастомозі. Матеріали і методи. На основі ознак якості та міцності, що були впроваджені для заварювання артерій, сформулювали первинні вимоги до параметрів експериментального випробувального стенда. Джерелом електрозварювальних імпульсів був адаптований клінічний апарат ЕК-300М1. Використовували електрозварювальний пінцет у варіантах пласких електродів та із зубоподібними елементами, затискачі без кремальєри – та з кремальєрою, з підвищеними можливостями стискання. В умовах гострого експерименту на ділянках кишки свині наклали 3 скобкові анастомози діаметром 29 мм, який містив 2 ряди скобок, та по 8 електрозварних кожним з інструментів. Всі анастомози відразу видаляли та досліджували міцність з’єднання та візуальні якості перетворень тканини. Результати досліджень та їх обговорення. Тиск витоку рідини для скобкового з’єднання склав (24,0±1,0) мм рт. ст. унаслідок прорізування скоб, а для затискача з можливістю стискання електродами тканини до 2 Н/мм2 склав (18,4±5,8) мм рт. ст., в діапазоні від 9,2 до 26,8 мм рт. ст., для решти інструментів – (10,6±7,2) мм рт. ст. Температура його електродів перебувала в діапазоні 53–86 оС. Задовільним визнали проходження електрозварного струму від 1 до 5 А у 65 % спроб.

25 September 2026 in GYNECOLOGY
Verified
Journal Article
Open access
PDF file
VTVictoria A. Tkachenko
Victoria A. Tkachenko
ТАТкаченко Виктория Александровна
Ткаченко Виктория Александровна
TPTatiana Yu. Pestrikova
Tatiana Yu. Pestrikova
ПЮПестрикова Татьяна Юрьевна
Пестрикова Татьяна Юрьевна
IBIrina A. Bloshchinskaya
Irina A. Bloshchinskaya
ЮВЮрасов Игорь Владимирович
Юрасов Игорь Владимирович
Spontaneous rupture of the kidney during pregnancy is an uncommon but potentially life-threatening condition that poses significant risks to both the mother and the child. The primary causes of kidney rupture during this period include the rupture of a kidney tumor (such as angiomyolipomas), gestational hydronephrosis, hypertensive disorders, thrombotic microangiopathies, trauma, and kidney infarction. One of the challenges in managing this condition is that the kidney is often not initially suspected as a source of bleeding, leading to a delay in the diagnosis of kidney rupture. This report analyzes a clinical case involving the successful intraoperative verification of renal angiomyolipoma during a cesarean section in a full-term pregnancy. A 32-year-old multiparous patient presented with acute pain in the right hypochondrium and lower back, along with hypotension and tachycardia, in the context of regular labor activity. This clinical presentation was initially misinterpreted as a sign of premature placental abruption. Due to a deterioration in fetal condition, an emergency cesarean section was performed, revealing a retroperitoneal hematoma of unknown origin. Following transfer to a specialized hospital, spiral computed tomography confirmed the diagnosis of a ruptured right kidney, which was verified during surgery. Nephrectomy was subsequently performed, and histological examination revealed the underlying cause to be renal angiomyolipoma. The postoperative recovery was uneventful, and the patient was discharged in satisfactory condition on Day 15 post-surgery. Pregnancy has the potential to prompt the growth of tumors such as angiomyolipoma, thereby increasing the risk of spontaneous rupture, particularly with the onset of labor. While this is a rare complication, it requires an interdisciplinary approach for effective diagnosis and treatment.

24 June 2024 in Russian Bulletin of Obstetrician-Gynecologist
Verified
Journal Article
Closed access
TPT.YU. Pestrikova
T.YU. Pestrikova
EYE.A. Yurasova
E.A. Yurasova
VTV.A. Tkachenko
V.A. Tkachenko
The review presents modern approaches to the definition of the concept of «meconial staining of amniotic fluid» in the context of its application in the International Classification of Diseases and Related Health Problems, Tenth Revision. A systematic review indicating a strong association between fetal hypoxia due to risk factors and meconial staining of amniotic fluid was conducted. The role of the infectious process is noted. The problems of complications for the mother (postpartum hemorrhage, purulent-septic diseases) and the newborn, including meconium aspiration syndrome, perinatal mortality are discussed. National and foreign tactics of delivery are presented.

30 June 2026 in Dalʹnevostočnyj medicinskij žurnal
Verified
Journal Article
Closed access
TPTatyana Yu. Pestrikova
Tatyana Yu. Pestrikova
VTVictoria A. Tkachenko
Victoria A. Tkachenko
IBIrina A. Bloshchinskaya
Irina A. Bloshchinskaya
TKTatyana P. Knyazeva
Tatyana P. Knyazeva