Yu Wang

Yu Wang

Auto-generated profile, based on publicly available information

Yu Wang

School of Mechanical Engineering 1 , Wuhan University of Science and Technology, Wuhan 430081

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2025 in Physics of Fluids
Verified
Journal Article
Closed access
ZWZhibing Wang
Zhibing Wang
FZFeng ZHANG
Feng ZHANG
THTiancai Huang
Tiancai Huang
YWYu Wang
Yu Wang
ZWZhaohui Wang
Zhaohui Wang
LHLiang Hu
Liang Hu
An implantable collamer lens (ICL) is a biocompatible artificial lens specifically designed to correct refractive errors in myopic patients with high precision and stability, but postoperative complications are observed after ICL implantation surgery. A novel ICL with drain channels is designed to improve the beneficial aqueous humor (AH) flow postoperatively and reduce the risk of visual impairment. This study analyzes the effects of conventional ICL, ICL with a central hole (Hole-ICL), and ICL with a drain channel (scICL) on AH flow. The impact of the geometric parameters of the drain channel in scICL on AH velocity and pupil flow rate is investigated. Additionally, a double-channel ICL (dcICL) is designed to analyze the impact of drain channel symmetry on AH flow. The results indicate the maximum velocities on the posterior chamber (PC) circle line are 2.24×10−6, 2.46×10−6, and 1.23×10−5 m/s for conventional ICL, Hole-ICL, and scICL in an up-facing eye, respectively. In both up-facing and horizontally facing eyes, the pupil flow rate in the scICL increase by 21% and 5.5%, respectively. The AH flow velocity reaches its maximum when the drain channel width is approximately 38% of the total scICL width and a concomitant proximity to the scICL thickness. When the width ratio and depth ratio of the dcICL are equal to zero (analogous to the scICL), the AH flow velocity and pupil flow rate reach their maximum. The scICL presented in this study improves the AH flow, reducing postoperative complications associated with ICL implantation and providing guidance for the clinical myopia treatment.

1 August 2025 in Physics of Fluids
Verified
Journal Article
Closed access
SPSitian Peng
Sitian Peng
FZFeng ZHANG
Feng ZHANG
LHLiang Hu
Liang Hu
PDPeng Dong
Peng Dong
THTiancai Huang
Tiancai Huang
AGAnle Ge
Anle Ge
Accurately predicting the temporal and spatial distribution of intraocular drugs to enhance anti-glaucoma treatment efficacy remains a significant challenge in clinical ophthalmology. Developing more precise numerical models of intraocular drug transport holds substantial clinical value. This study establishes a model of intraocular drug transport, which includes the trabecular meshwork (TM), collector channels (CC), and uveoscleral outflow pathway, and analyzes the parameters affecting aqueous humor (AH) outflow and the impact of the uveoscleral pathway on drug transport. Results indicate that the uveoscleral pathway influences AH outflow, with its porous media significantly impeding drug clearance, leading to drug accumulation in the anterior chamber and higher concentrations in the TM. A reduction in TM porosity or the number of CC hinders drug transport to varying extents, increasing peak drug concentration at TM targets by 11.27% and 12.8%, respectively. Furthermore, neglecting the uveoscleral pathway may result in an 10.93% underestimation of TM drug concentration. This study provides insight into the pathways involved in anti-glaucoma drug transport, contributing to the optimization of drug design for improved therapeutic outcomes.

1 July 2026 in Physics of Fluids
Verified
Journal Article
Closed access
YWYu Wang
Yu Wang
FZFeng ZHANG
Feng ZHANG
HLHaiyang Liu
Haiyang Liu
NZNan Zhou
Nan Zhou
TFTing Fu
Ting Fu
AGAnle Ge
Anle Ge
Pupillary block in PACG impedes aqueous humor (AH) flow through the iris–lens channel (ILC), while existing models that simplify the ILC geometry fail to accurately capture this flow and its role in PACG pathophysiology. A computational model is developed to investigate AH flow in the anterior segment of the human eye, in which the ILC is represented as a porous medium with variable porosity to account for different ILC conditions. The ILC is modeled as an equivalent porous medium to represent effective flow resistance rather than a physiological porous structure. The governing flow and solid mechanics equations are solved to systematically examine the effects of pupillary block severity on AH flow, pressure distribution, iris deformation, and energy dissipation. The results demonstrate that ILC porosity plays a critical role in determining the severity of pupillary block and the extent of anterior chamber angle (ACA) closure. When the porosity decreases below 0.35, the posterior–anterior pressure difference increases sharply to 419.14 Pa, driving anterior iris displacement and subsequent contact with the trabecular meshwork, thereby inducing ACA closure and increasing flow resistance and energy dissipation. In contrast, for porosities above 0.35, iris deformation is reduced by up to 67%, the ACA remains open, and AH flows smoothly, indicating a significantly alleviated pupillary block condition. This study provides new insight into the role of the ILC in pupillary block and suggests a novel therapeutic strategy based on modulation of ILC porosity to improve AH dynamics in PACG.