Mojtaba Safari

Mojtaba Safari

Auto-generated profile, based on publicly available information

Mojtaba Safari

The University of Chicago

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2023 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
MSMojtaba Safari
Mojtaba Safari
AFAli Fatemi
Ali Fatemi
LALouis Archambault
Louis Archambault
Purpose: This study proposed an end-to-end unsupervised medical fusion generative adversarial network, MedFusionGAN, to fuse computed tomography (CT) and high-resolution isotropic 3D T1-Gd Magnetic resonance imaging (MRI) image sequences to generate an image with CT bone structure and MRI soft tissue contrast to improve target delineation and to reduce the radiotherapy planning time. Methods: We used a publicly available multicenter medical dataset (GLIS-RT, 230 patients) from the Cancer Imaging Archive. To improve the models generalization, we consider different imaging protocols and patients with various brain tumor types, including metastases. The proposed MedFusionGAN consisted of one generator network and one discriminator network trained in an adversarial scenario. Content, style, and L1 losses were used for training the generator to preserve the texture and structure information of the MRI and CT images. Results: The MedFusionGAN successfully generates fused images with MRI soft-tissue and CT bone contrast. The results of the MedFusionGAN were quantitatively and qualitatively compared with seven traditional and eight deep learning (DL) state-of-the-art methods. Qualitatively, our method fused the source images with the highest spatial resolution without adding the image artifacts. We reported nine quantitative metrics to quantify the preservation of structural similarity, contrast, distortion level, and image edges in fused images. Our method outperformed both traditional and DL methods on six out of nine metrics. And it got the second performance rank for three and two quantitative metrics when compared with traditional and DL methods, respectively. To compare soft-tissue contrast, intensity profile along tumor and tumor contours of the fusion methods were evaluated. MedFusionGAN provides a more consistent, better intensity profile, and a better segmentation performance. Conclusions: The proposed end-to-end unsupervised method successfully fused MRI and CT images. The fused image could improve targets and OARs delineation, which is an important aspect of radiotherapy treatment planning.

5 February 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
CCChih-Wei Chang
Chih-Wei Chang
JPJunbo Peng
Junbo Peng
MSMojtaba Safari
Mojtaba Safari
ESElahheh Salari
Elahheh Salari
SPShaoyan Pan
Shaoyan Pan
Xiaofeng YangXiaofeng Yang
Xiaofeng Yang
Objective . High-resolution magnetic resonance imaging (MRI) can enhance lesion diagnosis, prognosis, and delineation. However, gradient power and hardware limitations prohibit recording thin slices or sub-1 mm resolution. Furthermore, long scan time is not clinically acceptable. Conventional high-resolution images generated using statistical or analytical methods include the limitation of capturing complex, high-dimensional image data with intricate patterns and structures. This study aims to harness cutting-edge diffusion probabilistic deep learning techniques to create a framework for generating high-resolution MRI from low-resolution counterparts, improving the uncertainty of denoising diffusion probabilistic models (DDPM). Approach . DDPM includes two processes. The forward process employs a Markov chain to systematically introduce Gaussian noise to low-resolution MRI images. In the reverse process, a U-Net model is trained to denoise the forward process images and produce high-resolution images conditioned on the features of their low-resolution counterparts. The proposed framework was demonstrated using T2-weighted MRI images from institutional prostate patients and brain patients collected in the Brain Tumor Segmentation Challenge 2020 (BraTS2020). Main results . For the prostate dataset, the bicubic interpolation model (Bicubic), conditional generative-adversarial network (CGAN), and our proposed DDPM framework improved the noise quality measure from low-resolution images by 4.4%, 5.7%, and 12.8%, respectively. Our method enhanced the signal-to-noise ratios by 11.7%, surpassing Bicubic (9.8%) and CGAN (8.1%). In the BraTS2020 dataset, the proposed framework and Bicubic enhanced peak signal-to-noise ratio from resolution-degraded images by 9.1% and 5.8%. The multi-scale structural similarity indexes were 0.970 ± 0.019, 0.968 ± 0.022, and 0.967 ± 0.023 for the proposed method, CGAN, and Bicubic, respectively. Significance . This study explores a deep learning-based diffusion probabilistic framework for improving MR image resolution. Such a framework can be used to improve clinical workflow by obtaining high-resolution images without penalty of the long scan time. Future investigation will likely focus on prospectively testing the efficacy of this framework with different clinical indications.

16 June 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MSMojtaba Safari
Mojtaba Safari
SWShansong Wang
Shansong Wang
ZEZach Eidex
Zach Eidex
QLQiang Li
Qiang Li
LQLei Qiu
Lei Qiu
Xiaofeng YangXiaofeng Yang
Xiaofeng Yang
Objective. Magnetic resonance imaging (MRI) is essential in clinical and research contexts, providing exceptional soft-tissue contrast. However, prolonged acquisition times often lead to patient discomfort and motion artifacts. Diffusion-based deep learning super-resolution (SR) techniques reconstruct high-resolution (HR) images from low-resolution (LR) pairs, but they involve extensive sampling steps, limiting real-time application. To overcome these issues, this study introduces a residual error-shifting mechanism markedly reducing sampling steps while maintaining vital anatomical details, thereby accelerating MRI reconstruction. Approach. We developed Res-SRDiff, a novel diffusion-based SR framework incorporating residual error shifting into the forward diffusion process. This integration aligns the degraded HR and LR distributions, enabling efficient HR image reconstruction. We evaluated Res-SRDiff using ultra-high-field brain T1 MP2RAGE maps and T2-weighted prostate images, benchmarking it against Bicubic, Pix2pix, CycleGAN, SPSR, I2SB, and TM-DDPM methods. Quantitative assessments employed peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), gradient magnitude similarity deviation (GMSD), and learned perceptual image patch similarity. Additionally, we qualitatively and quantitatively assessed the proposed framework’s individual components through an ablation study and conducted a Likert-based image quality evaluation. Main results. Res-SRDiff significantly surpassed most comparison methods regarding PSNR, SSIM, and GMSD for both datasets, with statistically significant improvements ( p -values ≪ 0.05 ). The model achieved high-fidelity image reconstruction using only four sampling steps, drastically reducing computation time to under one second per slice. In contrast, traditional methods like TM-DDPM and I2SB required approximately 20 and 38 s per slice, respectively. Qualitative analysis showed Res-SRDiff effectively preserved fine anatomical details and lesion morphologies. The Likert study indicated that our method received the highest scores, 4.14 ± 0.77 (brain) and 4.80 ± 0.40 (prostate). Significance. Res-SRDiff demonstrates efficiency and accuracy, markedly improving computational speed and image quality. Incorporating residual error shifting into diffusion-based SR facilitates rapid, robust HR image reconstruction, enhancing clinical MRI workflow and advancing medical imaging research. Code available at https://github.com/mosaf/Res-SRDiff

30 May 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MSMojtaba Safari
Mojtaba Safari
Xiaofeng YangXiaofeng Yang
Xiaofeng Yang
CCChih-Wei Chang
Chih-Wei Chang
RQRichard L J Qiu
Richard L J Qiu
AFAli Fatemi
Ali Fatemi
LALouis Archambault
Louis Archambault
Objective. This study developed an unsupervised motion artifact reduction method for magnetic resonance imaging (MRI) images of patients with brain tumors. The proposed novel design uses multi-parametric multicenter contrast-enhanced T1W (ceT1W) and T2-FLAIR MRI images. Approach. The proposed framework included two generators, two discriminators, and two feature extractor networks. A 3-fold cross-validation was used to train and fine-tune the hyperparameters of the proposed model using 230 brain MRI images with tumors, which were then tested on 148 patients’ in-vivo datasets. An ablation was performed to evaluate the model’s compartments. Our model was compared with Pix2pix and CycleGAN. Six evaluation metrics were reported, including normalized mean squared error (NMSE), structural similarity index (SSIM), multi-scale-SSIM (MS-SSIM), peak signal-to-noise ratio (PSNR), visual information fidelity (VIF), and multi-scale gradient magnitude similarity deviation (MS-GMSD). Artifact reduction and consistency of tumor regions, image contrast, and sharpness were evaluated by three evaluators using Likert scales and compared with ANOVA and Tukey’s HSD tests. Main results. On average, our method outperforms comparative models to remove heavy motion artifacts with the lowest NMSE (18.34±5.07%) and MS-GMSD (0.07 ± 0.03) for heavy motion artifact level. Additionally, our method creates motion-free images with the highest SSIM (0.93 ± 0.04), PSNR (30.63 ± 4.96), and VIF (0.45 ± 0.05) values, along with comparable MS-SSIM (0.96 ± 0.31). Similarly, our method outperformed comparative models in removing in-vivo motion artifacts for different distortion levels except for MS- SSIM and VIF, which have comparable performance with CycleGAN. Moreover, our method had a consistent performance for different artifact levels. For the heavy level of motion artifacts, our method got the highest Likert scores of 2.82 ± 0.52, 1.88 ± 0.71, and 1.02 ± 0.14 (p-values ≪ 0.0001) for our method, CycleGAN, and Pix2pix respectively. Similar trends were also found for other motion artifact levels. Significance. Our proposed unsupervised method was demonstrated to reduce motion artifacts from the ceT1W brain images under a multi-parametric framework.

1 November 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
MSMojtaba Safari
Mojtaba Safari
MBManjieh Beiki
Manjieh Beiki
AAAhmad Ameri
Ahmad Ameri
STSaeed Hosseini Toudeshki
Saeed Hosseini Toudeshki
AFAli Fatemi
Ali Fatemi
LALouis Archambault
Louis Archambault
Background and Purpose.The world health organization recommended to incorporate gene information such as isocitrate dehydrogenase 1 (IDH1) mutation status to improve prognosis, diagnosis, and treatment of the central nervous system tumors. We proposed our Shuffle Residual Network (Shuffle-ResNet) to predict IDH1 gene mutation status of the low grade glioma (LGG) tumors from multicenter anatomical magnetic resonance imaging (MRI) sequences including T2-w, T2-FLAIR, T1-w, and T1-Gd.Methods and Materials.We used 105 patient's dataset available in The Cancer Genome Atlas LGG project where we split them into training and testing datasets. We implemented a random image patch extractor to leverage tumor heterogeneity where about half a million image patches were extracted. RGB dataset were created from image concatenation. We used random channel-shuffle layer in the ResNet architecture to improve the generalization, and, also, a 3-fold cross validation to generalize the network's performance. The early stopping algorithm and learning rate scheduler were employed to automatically halt the training.Results.The early stopping algorithm terminated the training after 131, 106, and 96 epochs in fold 1, 2, and 3. The accuracy and area under the curve (AUC) of the validation dataset were 81.29% (95% CI (79.87, 82.72)) and 0.96 (95% CI (0.92, 0.98)) when we concatenated T2-FLAIR, T1-Gd, and T2-w to produce an RGB dataset. The accuracy and AUC values of the test dataset were 85.7% and 0.943.Conclusions.Our Shuffle-ResNet could predict IDH1 gene mutation status using multicenter MRI. However, its clinical application requires more investigation.

22 June 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
MSMojtaba Safari
Mojtaba Safari
AFAli Fatemi
Ali Fatemi
YAYounes Afkham
Younes Afkham
LALouis Archambault
Louis Archambault
Purpose: To investigate the impact of MRI patient‐specific geometrical distortion (PSD) on the quality of Gamma Knife stereotactic radiosurgery (GK‐SRS) plans of the vestibular schwannoma (VS) tumors.Methods and materials: Three open access datasets including the MPI‐Leipzig Mind‐Brain‐Body (318 patients), the slow event‐related fMRI designs dataset (62 patients), and the VS dataset (242 patients) were used. We used first two datasets to train a 3D convolution network to predict the distortion map of third dataset that were then used to calculate and correct the PSD. GK‐SRS plans of VS dataset were used to evaluate dose distribution of PSD‐corrected MRI images. GK‐SRS prescription dose of VS cases was 12 Gy. Geometric and dosimetric discrepancies were assessed between the dose distributions and contours before and after the PSD corrections. Geometry indices were center of the contours, Dice coefficient (DC), Hausdorff distance (HD), and dosimetric indices were , , , and doses, target coverage (TC), Paddick's conformity index (PCI), Paddick's gradient index (GI), and homogeneity index (HI).Results: Geometric distortions of about 1.2 mm were observed at the air‐tissue interfaces at the air canal and nasal cavity borders. Average center of the targets was significantly distorted along the frequency encoding direction after the PSD‐correction. Average DC and HD metrics were 0.90 and 2.13 mm. Average , and in Gy significantly increased after PSD correction from 16.85 to 17.25, 12.30 to 12.77, and from 8.98 to 9.92. did not significantly change after the correction. Average TC and PCI significantly increased from 0.97 to 0.98, and 0.94 to 0.96. Average GI decreased significantly from 2.24 to 2.15 after PSD correction. However, HI did not significantly change after the correction.Conclusion: The proposed method could predict and correct the PSD that indicates the importance of PSD correction before GK‐SRS plans of the VS patients.